– 1 –
– 1 –
fit over the recessed portions of the tub wall.
See Figure 10.
8. Tub & Tray
a. insert the large rubber stopper in the drain
hole.
See Figure 11
.
.
9. Replacing the Water Pump
• in the event of a water pump failure, replace
the pump by performing the following steps:
a. remove the cable gland located at the bottom
of the vertical arm shield by turning it counter-
clockwise. once removed, the cable should
slide freely within the underlying sleeve.
See
Figure 13
.
B. remove screws from the vertical arm shield,
then remove the shield.
c. disconnect wiring from the water pump power
cable within the vertical arm.
d. extract the power cable from the vertical arm
through the sleeve at the bottom of the shield.
Keep the cable gland.
e. remove the water pump underneath the rails
and install a new one in its place. remove the
water tube and adapter from the failed pump.
f. insert power cable from the new pump through
the cable gland and shield sleeve and route it
up the vertical arm. the gland must be
oriented such that it can attach to the sleeve.
G. connect wiring from the water pump power
cable to the same wires made available when
disconnecting the failed pump.
h. install shield onto vertical arm using screws.
i. Gently extract excess cable stored within
vertical arm; some slack is ideal.
Tugging the
cable may dislodge or disconnect critical
electrical components.
attach cable gland
onto the shield sleeve by turning clockwise.
if properly attached, the gland should secure
the cable in place.
J. attach the adapter to the pump and hand
tighten.
Do not use a wrench
as it can strip
the thread.
K. connect clear tubing to male section of the
adapter until it fits securely.
See Figure 14.
Adapter
Water tubing
Figure 1
Figure 10
Positioning the Saw
Recessed wall
Bracket
Figure 11
Rubber stopper
Figure 1
Remove Cable Gland