Operating Instructions
Operation
PPH25RR*** / 000
5-7
• Press the Water On/Off button on the remote controller to I
• Open the water valve on the Drive Unit PPH25RR***
– water emerges from the cutting tool
• The Drive Unit PPH25RR*** is ready for operation
5.4.2
Soft start
The Drive Unit PPH25RR*** provides the option of a soft start.
The soft start is used mainly for diamond wire sawing.
Proceed as follows
• Start the Drive Unit PPH25RR***,
see "Chapter 5" 5.4.1,
5-6
• Turn the main motor potentiometer to the 0 position
• Select the desired pressure stage,
see "Chapter 5", 5.4.3,
5-8
• Turn the main motor potentiometer slowly to
100% power
Information
If the Drive Unit PPH25RR*** is switched off after the electric motor has
once been started up, in order to start up again it is only necessary to
press the main switch on the remote controller just once more.