8 Technical data

EN Floor grinding machine FGE 400

13

8 Technical data

Designation

FGE 400

Rated voltage

400 V, 3

Rated frequency

50 Hz

Rated current

8,5 A

Rated power

(6) 4 kW

Connecting cable

5 x min. 2,5 mm

2

(max. 25 m)

5 x min. 4,0 mm

2

(>25 m)

Tool speed

900 rpm

Protection rating

IP 23

Dust extraction

50 mm

Dimensions (L x W x H)

ca. 650 x 450 x 750 mm

Working width

400 mm

ETX locating plate

400 mm

Edge distance

min. 10 mm

Grinding pressure

32 ... 64 kg

Weight

109 kg

Noise level

79 dB(A)

Vibration total value *)

±

2,5 m/s

2

*)

determined under standardised manufacturer operation conditions according to measuring method HARM.

Summary of Contents for FGE 400

Page 1: ...1 10999140_en EN Floor grinding machine FGE 400 Translation of the original operating manual 4...

Page 2: ...2 4 2 5 7 1 8 Fig A 3 6 9 Fig B 12 1 10 11 2 Fig C 13 13 17 Fig E 14 14 16 Fig D 15 Fig F 18 19 Fig G 3 Fig H 20 21 Fig J 22 6 5 1 8 9 7 4 23 Fig K Fig L 24 25...

Page 3: ...3 Fig M Fig N Fig P Fig R...

Page 4: ...3 Switching the machine off 8 4 Maintenance 9 4 1 Customer service and spare parts 9 4 2 Attaching Removing additional weights 9 4 3 Tilting the machine 9 4 4 Mounting and dismantling ETX diamond tool...

Page 5: ...rried out inadequately or incorrectly Specified spare parts were not used The safety devices were not used have been altered or were removed The specified power supply ratings and surroun ding conditi...

Page 6: ...ny defects are found in the machine that could endanger people or damage property stop the machine immediately and ensure that it cannot be used again until all repairs are com pleted Warning signs Fi...

Page 7: ...3 1 Starting up the machine The initial start up of the machine may be car ried out only by qualified personnel A visual inspection of the machine needs to be carried out before starting up the machi...

Page 8: ...started up Make sure that it is stan ding securely and that the guide handle is in the correct position When the machine is in operation do not touch any part of the machine outside the gripping range...

Page 9: ...e over the bolts The removal is carried out in logical reverse order 4 3 Tilting the machine Before tilting the machine always make sure that it is on an even level floor surface 1 Disconnect the powe...

Page 10: ...the machine The machine may only be transported if it has been switched off and the ETX locating plate is at a standstill Risk of injury from heavy loads Suspended loads can slide out of place fall o...

Page 11: ...e g a pallet The grinding plate and the wheels must rest on the transport device d When transporting the machine with a ve hicle or suitable transport device always ensure that the machine is secured...

Page 12: ...ittle Correct the distance between rubber lip and the surface to be ground Chapter 3 1 Grinding pattern is uneven Tools are loose Fasten tools Tools are damaged or worn Replace tools Machine shuts dow...

Page 13: ...mm2 max 25 m 5 x min 4 0 mm2 25 m Tool speed 900 rpm Protection rating IP 23 Dust extraction 50 mm Dimensions L x W x H ca 650 x 450 x 750 mm Working width 400 mm ETX locating plate 400 mm Edge distan...

Page 14: ...TYROLIT Hydrostress AG Witzbergstrasse 18 CH 8330 Pf ffikon ZH Switzerland Telefon 41 0 44 952 18 18 Telefax 41 0 44 952 18 00 URL www tyrolit com...