TO REMOVE FAULTS FROM MEMORY :
To clear a fault from the system memory the problem causing the fault must be rectified, then the
associated Intercom Unit must be called back.
Any SYSTEM FAULTS stored in memory ie. MAINS FAIL, BT LINE FAULT, etc, will automatically be
removed when the fault is rectified.
Follow the procedure described above and make a note of all the channel numbers with fault conditions.
1. Enter the faulty channel number using the Portable Master Unit keyboard.
2. Press the
SPK
key once.
3. Press the
CAN
key to cancel the call.
4. If the fault has been rectified it will be cleared from the memory, if it still exists it will be re-reported to
the Portable Master Unit.
5. If the fault re-reports, press the
SPK
key followed by the
5
key and the fault will be PARKED in the
system memory again.
6. Repeat for all faulty channel numbers stored in the memory.
12. INDEX FACILITY
Daily calls to all residents can be greatly simplified by using the INDEX facility. You can start sequential
calls at any flat number.
1. Call the first resident in the normal way.
2. When you wish to call the next resident, rather than pressing the
CAN
key to end the call, press the
IND
key once. The current call will be cancelled and the display will change to show the next channel
number.
3. Press the
SPK
key and you will engage the channel displayed.
4. If you wish to skip a resident, press the
IND
key again and the display will change to the next
channel number. This procedure can be repeated at will.
5. Press the
CAN
key to terminate sequential calls.
(
c) Tynetec Limited 2001
FM0313e.PDF issue A Page 11