30
Connecting components to the modular contacts (maximum cable cross-sectional area for RJ10. 0.9mm/ 0.2mm², AWG24)
Unit
Position Pin
Comment
Temp. sensor (10 k
Ω
)
1
2-3
Must be NTC type. May also be connected at Position 4.
External switch without LED
indication
2
3-4
Both constant and impulse deactivation work.
External switch with LED indication
2
2-3-4
12VDC (maximum 40mA). Tylö external switch, item number: 9090
8045
Door contact without alarm for door
status
3
3-4
Of type NO (Normally Open). Tylö door contact, Item No.: 9090 8035.
Door contact with alarm for door
status
3
2-3-4
12VDC (max. 40mA)