Start

To start the sauna, press (C). The last temperature setting and operating time will be used. The symbol 

will light in the indicator field to show that the heater has started. 

To switch off the sauna before the end of the operating time set, press the same button again. 

Setting temperature

Use the function selection buttons (F) to select temperature setting. Use the - and + buttons to then 

select temperature setting 1-10. The temperature obtained depends on the max. temperature set, i.e. 

which program has been set. Temperature can be adjusted whilst taking a sauna if required.

Max. temperature

Set temperature (approx. value, °C)

1

2

3

4

5

6

7

8

9

10

90 °C

60

63

67

70

73

77

80

83

87

90

194 °F

140

145

153

158

163

171

176

181

189

194

Once the temperature has been set and the heater started, the set temperature will be indicated con-

tinuously and actual temperature will be indicated by a flashing indicator. Once the actual temperature 

reaches the set value, the flashing will stop.

Setting delayed start

You can set a time when the heater is to start after a certain time. Use the function selection buttons (F) 

to select the timer symbol. Use the – and + buttons to select the number of hours until the heater is to 

start (1-10 hours). Activate delayed start by pressing the Start button (C). 

The indicator symbol for delayed start will light (field B) and the time delay LED will start to flash. The 

flashing indicator will count down and show the actual time remaining until the heater starts. Once the 

heater starts, the panel will switch to showing set temperature automatically.

Setting sauna time

Sauna time is set when the heater is OFF. Use the function selection buttons (F) to select operating time 

setting. Use the - and + buttons to then select operating time 1-10. Operating time depends on the max. 

operating time set, i.e. which program has been set. 

24 hour operation is for commercial applications only with attendants on site to routinely check the 

sauna.

Version

LED indicators

1

2

3

4

5

6

7

8

9

10

1 h

6 min 12 min 18 min 24 min 30 min 36 min 42 min 48 min 54 min

1 h

24 h

2 h

4 h

6 h

8 h

10 h

12 h

14 h

16 h

18 h

24 h

Summary of Contents for PURE

Page 1: ...161013 Art nr 2900 5201 PURE ...

Page 2: ... given to the heater sauna owner or per son responsible for servicing after installation Notice d installation et mode d emploi Français page 8 Lisez les notices et les instructions relatives au poêle pour sauna et au générateur de vapeur Le branchement doit être réalisé par un électricien habilité CONSERVEZ LES NOTICES Après l installation elles sont remises au propriétaire du sauna hammam ou à c...

Page 3: ... with bracket 2 Installation without bracket 2 User Guide 3 First start 3 Start 4 Setting temperature 4 Setting delayed start 4 Setting sauna time 4 Setting humidity 5 Connecting door contact and its function 5 Using an external switch 5 Error message 6 English ...

Page 4: ...t when seen from below Mount the bracket as low as possible on the control panel Install the panel on the wall Use the control panel wire supplied to connect the panel to the heater If the wire is too long cut it to the appropriate length and use the extra contact supplied NB special pliers are required crimp pliers for RJ10 Installation without bracket Attach the double sided adhesive to the cont...

Page 5: ... selection buttons First start Set heater switch to ON The indicator diodes B will flash a few times This indicates that the control panel is connecting to the heater When contact is made the diodes will cease flashing and diodes 1 7 D corresponding to the program no selected will flash 4 times to show setting This will also occur after any disconnection of power Pure s default setting is to regul...

Page 6: ...he flashing will stop Setting delayed start You can set a time when the heater is to start after a certain time Use the function selection buttons F to select the timer symbol Use the and buttons to select the number of hours until the heater is to start 1 10 hours Activate delayed start by pressing the Start button C The indicator symbol for delayed start will light field B and the time delay LED...

Page 7: ...ng diagram supplied with external switch for connection We recommend using Tylö s external switch item number 90908045 This also provides indication via LED of whether the sauna is on programmed for delayed start and error status for a magnetic door contact if fitted A continuous light indicates that the heater is on Slow flash indicates that the heater is programmed for delayed start Rapid flash ...

Page 8: ...d and must be reset 7 n a 8 n a 9 Door Switch is open for more than 60 seconds while heating or jumper on circuit board in heater is removed 10 Door Switch is open for more than 60 seconds in Delay Mode or jumper on circuit board in heater is removed For certain errors turning of circuit breaker to remove power to the heater for a brief period minumum of 60 seconds and then reconnecting can be tri...

Page 9: ...ce d utilisation 9 Lors de la première mise en marche 9 Démarrage 10 Réglage de la température 10 Réglage des démarrages différés 10 Réglage de la séance souhaité 11 Raccordement du contact de porte et fonctions 11 Utilisation de l interrupteur extérieur 11 Messages d erreur 12 Français ...

Page 10: ...neau de com mande sur la cloison Utilisez le câble du panneau de commande joint pour raccorder ce dernier au poêle du sauna Si le câble du panneau de commande est trop long il est possible de le couper et d utiliser le connecteur supplémentaire joint ATTENTION une pince spéciale est nécessaire pince à dénuder pour RJ10 Montage sans support Fixez l adhésif double face sur le panneau de commande Ava...

Page 11: ...e sur la position ON marche Les voyants de contrôle B commencent à clignoter plusieurs fois Ils indiquent la connexion du panneau de commande avec le poêle Une fois le contact établi les voyants arrêtent de clignoter et les voyants 1 à 7 D correspondant aux numéros de programmes paramétrés clignotent 4 fois afin d indiquer lequel est paramétré même après une coupure de courant À la livraison Pure ...

Page 12: ...mpérature à l aide des boutons de sélection de fonc tions F Utilisez ensuite les boutons et pour sélectionner la température souhaitée de 1 à 10 La température obtenue dépend de la température maximale paramétrée et donc du programme sélec tionné Il est également possible de modifier la température pendant la séance si vous le souhaitez Température maximale Température paramétrée valeur approximat...

Page 13: ...r réactiver le programme pour un démarrage différé appuyez sur le bouton et fermez la porte dans un délai de 60 secondes Si le panneau est placé à l intérieur du sauna vous disposez de 60 secondes pour sortir et fermer la porte après avoir activé le démarrage différé Si la porte est ouverte en cours de séance et reste ouverte plus de 5 minutes le poêle s arrête et le code d erreur 19 s affiche sur...

Page 14: ...apteurs de températures raccordés trop nombreux 19 La porte est restée ouverte plus de 5 minutes alors que le sauna était en marche 20 La porte est restée ouverte plus de 60 secondes après le dernier arrêt ou le démarrage différé a été activé et la porte est restée ouverte plus de 60 secondes après l activation Pour certains défauts il est possible de mettre le poêle hors tension pendant quelques ...

Page 15: ...13 ...