Precautions to be taken before commissioning Warning (space configuration and use):

 

  Correct electrical earthing is required 

  Electrical sockets are not permitted in the sauna. 

  Do not allow heating elements to come into contact with water. 

  Do not fit a lock or bolt on the door. 

  Do not block the ventilation holes. 

  Children must always be supervised in the sauna. 

  Clean the sauna with a damp cloth. 

  Cleaning the sauna with steam cleaners, high pressure cleaners or spraying with water is not permitted. 

Warning notice: Do not insert the sauna power cable into a socket before assembly is complete. 
Warning (health restrictions): 

  Being exposed to high temperatures for a long time may lead to hyperthermia (body temperature is several 

degrees above 37° Celsius) 

  Hyperthermia symptoms include: dizziness, lethargy, grogginess and feeling faint. Effects of hyperthermia:  

o

  Failure to realise that you have to leave the infrared sauna.  

o

  Damage to the foetus in pregnant women. 

o

  Being physically unable to leave the sauna. 

o

  Loss of consciousness  

  Warning – the consumption of alcohol or drugs increases the risk of fatal hyperthermia. 

  If you have health problems or are ill, consult your doctor before using the sauna.  

  Stop using it immediately if you feel restless, if you start shaking, if you have a headache or feel sick 

or nauseous. 

  People who suffer from hyperthermia or cardiovascular diseases should seek medical advice before 

using the infrared sauna. 

  Do not use a sauna if you have drunk alcohol or taken tranquillisers or if you suffer from pain in the heat. 

  Using the infrared sauna is not advisable if you have been exposed to UV radiation (a solarium or been 

sunbathing) in the last 24 hours. 

  Should you notice unusual skin changes after using the infrared sauna e.g. persistent erythema (reddening 

of the skin for more than one day) or a reticular change in colour, you should stop using it and seek medical 

advice. 

Warning (fire risk): 

  Do not use the sauna to dry clothing, bathing costumes etc. 

  Do not hang towels or other objects on or in front of the infrared heat radiator. 

  Never operate the infrared sauna with a damaged cable or a damaged socket. 

Pre-assembly information: 

a. Two (2) adults are required for assembling and installing the sauna. 

b. Assembly tools: Phillips screwdriver 

c.

 The

 

boxes are labelled in order of assembly.

 

d. Note: The glass for assembling the front sauna panel is heavy and fragile. 

Box 

1:  

Floor, ceiling

long bench valance, short bench valance, fan component, manual, 

Pack of 10 Phillips screws for the junction box covers 

Box 2:  

Left and right wall panels 

Long and short bench 

Box 

3:  

Left front, right front and front wall panel  

Electrical requirements: 

The infrared sauna must have a 230 volt connection. 

 

 

Page 2 

 

Summary of Contents for Prime+ 1515/C

Page 1: ...ore commissioning 2 Pre assembly information 2 Electrical requirements 2 Cabin construction assembly 3 Junction box connections 3 Main junction box connections 7 Power connections on the ceiling 9 Control panel instructions 12 Lighting Internal external colour therapy 12 Maintenance technical support 13 Wiring diagram 14 121210 Page 1 ...

Page 2: ... shaking if you have a headache or feel sick or nauseous People who suffer from hyperthermia or cardiovascular diseases should seek medical advice before using the infrared sauna Do not use a sauna if you have drunk alcohol or taken tranquillisers or if you suffer from pain in the heat Using the infrared sauna is not advisable if you have been exposed to UV radiation a solarium or been sunbathing ...

Page 3: ...on junction boxes that are labelled accordingly and must be connected after assembling each section Left back wall panel Right back wall panel Left front Right front Left bench valance B1 to B1 B2 to B2 L1 to L1 R1 to R1 S3 to S3 Right bench valance Left bench Right bench S4 to S4 S1 to S1 S2 to S2 These 8 power plugs are connected easily by simply inserting the white plug of the white junction bo...

Page 4: ...ot of the floor panel The back left rear panel section must be held in position while the right rear panel section is located Place the right wall panel section into the back right hand slot of the floor panel Connect the right back panel section to the left back panel section o Lift the right back panel and push it onto the wall bracket Connect the power connections to the B 1 junction box Fix th...

Page 5: ...ox Fix the cover of the L 1 junction box with 2 Phillips screws Note Put the glass sections aside until the Front panel section Right side panel Box 3 Place the right wall panel section into the right hand slot on the floor panel Attach the right wall panel to the back wall panel by lifting the right panel and pushing it into the retaining bracket on the back panel Connect the R 1 electrical suppl...

Page 6: ...s screws Slide the fan component Box 1 into the retaining bracket on the bench valance Connect the white connection of the black junction box to the white connection on the fan Right bench valance Box 1 Insert the bench valance between the left bench valance and the right side panel Connect the S 4 electrical supply to the S 4 junction box Fix the cover of the S4 junction box with 2 Phillips screw...

Page 7: ...ction box Set the switch as shown above to the ON EIN position 3 Connect the loudspeaker input and output Note Do NOT insert the 230 volt alternating current cable into the socket yet Long bench Box 2 Rest the bench upright against the back wall panel Connect the S 1 power supply to the S 1 junction box Fix the cover of the S 1 junction box with 2 Phillips screws Lay the bench down and push first ...

Page 8: ...and push first the right hand and then the left hand edge into position Push the seat onto the back wall panel Front wall panel Place the left hand glass section into the floor slot and the slot in the left hand wooden panel Note The long loop on the seal should be on the inside of the two fixed panels Place the right hand glass section into the floor slot and the slot in the right hand wooden pan...

Page 9: ... an elevated position When the cables have been pulled through remove the styropor blocks and lower the ceiling onto the panels Lower the ceiling carefully onto the 4 wall panels Doors Put the fixed right hand side section attached to the door into the floor slot provided Align the door vertically to the ceiling edge until it touches the ceiling section Lift the ceiling section up and place the fi...

Page 10: ...ation manual 1 Take the dipole antenna black wires out of the bag in the installation manual 2 Öpen the cover on the top of the ceiling above the touch screen 3 Connect the dipole antenna to the wire marked 7 4 Spread the wire out and pull it apart to improve FM radio reception Ceiling to the rear panel 4 connections Lift the door panel on the top left of the rear external face of the ceiling You ...

Page 11: ...De luxe door handles Inside Outside Your infrared sauna is now ready for use Page 11 ...

Page 12: ... 2 Press and hold or to set the required temperature Pressing once will increase or reduce the setting in one degree intervals You can also run your finger over the temperature bar The central temperature display shows the actual sauna temperature 3 Press to set the bench leg floor heat to ON or OFF Red waves can be seen in heating mode and white ones in OFF mode Light functions 1 Press Inside lig...

Page 13: ... Troubleshooting tips a Main control panel lights not lit up Check the electrical connections between the ceiling and the back wall panel and the front wall panel Ensure that the plug is correctly connected to the socket and the switch Ensure that the main switch house is not switched off socket has power Ensure that the main control switch under the bench is not switched off and is ON b The sauna...

Page 14: ...Wiring Diagram Page 14 ...