1. Purpose and principle of function
The essence pump is an optional extra for steam generators and saunas. It is connected to the steam generator's steam pipe, and
feeds a selectable amount of fragrance into the pipe at regular intervals. The fragrance mixes with the steam and is sprayed into the
sauna to give a pleasant scent.
The pump is intended to be controlled from certain Tylö steam generators, and is therefore connected to the generator connection
terminal according to fig. 5. The pump can also be controlled from an alternative 230VAC source which will provide current for as
long as the pump is set to run. The pump can also be controlled via a constant connection on the signal cable, but the signal
converter shown in fig. 5
must
be disconnected. In this instance, the pump will run as long as there is a connection on the cable.
NB: If the signal converter is disconnected, the pump can no longer be powered by 230V.
2. Safety instructions
Before installing and using the essence pump, read the installation/user guide. All points must be observed. The manufacturer
cannot be held liable for damage caused by incorrect installation or use.
WARNINGS
•
The pump is only suitable for use with fragrances recommended by the supplier.
•
Never try to open the pump.
•
Never install the pump in an area containing flammable, explosive or corrosive items.
•
Install the pump in a dry place. Do not install in a sauna or other room with a high level of humidity.
•
Check the pump regularly for correct operation.
•
Always disconnect the pump from the power supply and disconnect the signal cable before performing any form of installation,
removal, connection or maintenance on the pump.
•
Check that there is no liquid left in the pump and hoses by disconnecting it from the fragrance holder and manually pumping for
a few seconds before transporting the pump.
3. Technical Data
•
Set pumping/pause times as follows: pumping 0.1 - 9.9 seconds and continuous pumping. Pause 1 - 60 min (time between
pumpings).
•
Pump capacity approx 150ml/min. Pressure 2 bar.
•
Signal converter before activation with 230VAC.
•
Thermostat with +70°C cut-in temperature.
•
Power supply: Prim. 100 - 230VAC 50/60Hz. Sec. 24VDC 15W max
•
Pump dimensions: 80 x 90 x 100mm (WxDxH).
•
Pump weight: approx.: 0.6kg
•
Temperature range: Running min. +5° C, max. +50° C.
4. Components
•
Essence pump including signal converter 230VAC and ther70°C with 3m cable each.
•
Power cord
•
Suction hose (yellow) 0.5m long, outer diameter 8mm, inner diameter 4mm.
•
Feed hose (green) 3m long, outer diameter 8mm, inner diameter 2mm.
•
Connection for feed hose to steam pipe 1/8” thread.
•
Installation and user guide.
•
Adapter for using small fragrance holders 10L and less.