background image

Before

Us

age

Sa

fe

ty

Pr

e

ca

u

ti

o

n

s

an

d

W

ar

ni

ng

s

S

afety Precautions and Warnings

Do not use if the power cord is damaged or in a  
loose power outlet.

Do not pull the power cord. Never touchthe power  
cord or the power outlet with wet hands.

Do not forcibly bend, squeeze, damage or crush  
the power cord under heavy objects.

Unplug the power cord during general maintenance,  
repair and inspection and while replacing parts.

Do not use power surge protectors with this unit.  
Use unit with its own dedicated power source.

Regarding the Power Supply

B

efore Usage

Safety precautions are provided for the safe and proper use of this unit and can prevent
danger, bodily harm and/or possible damage due to misuse. Please make sure you are
familiar with all the safety precautions and warnings associated with this unit.

DANGER (Red Warning Sign) indicates an imminent hazard that could result in serious injury  
or death. If you see this sign, stop using this unit immediately.

WARNING (Orange Warning Sign) indicates a potential hazard that could result in significant  
bodily harm or damage to the unit. If you see this sign, stop the use of this unit.

ATTENTION  (Yellow Warning Sign) indicates a potential hazard that could result in minor  
bodily harm or damage to the unit.

1.

Do not drink functional water with medication. When taking medication, use

“clean H

2

O”

filtered water thirty minutes prior to taking medication as well as with medication.
You may resume drinking functional water thirty minutes after taking medication.

2.

Always consult your primary care physician before drinking functional water. Only
drink a small amount near a neutral pH level for the first week. This will give the body
time to adjust to functional water during the detoxification period. See Welcome
Guide for full details on getting started.

3.

If you notice any negative effects from drinking functional water, stop drinking the
functional water immediately and consult your primary care physician about
changes in your

body’s pH level.

4.

If you are currently under the care of a primary care physician for an existing condi-
tion, consult your primary care physician about how changes in pH and other
characteristics of functional water could affect your medical condition.

5.

If you suffer from gastric anacidity, kidney failure or potassium excretion, you should
not drink functional water.

6.

Verify the pH levels of the functional water dispensed from this unit on a monthly
basis to ensure proper function. This can be done with the supplied reagent drops
and a pH color chart.

7.

When switching from one pH to another, it is good practice to let the water run for
several seconds before using.

8.

It is common to drink half your body weight in ounces. For example, if you weigh 180
pounds, it may be wise to drink 90 ounces every day of water per day. This especially
applies after you have given your body some time to adjust to the new pH level.

9.

The recommended drinking level for functional water is 9.5 pH (+-0.3). It is not
recommended to drink functional water above a pH of 10.

10.

If you wish to store functional water, use a glass or other nonleaching material with

an airtight lid and store it in the refrigerator. Functional water will begin to weaken
immediately and will lose most of its benefits after 3 days.

11.

Never run hot water through this unit.

12.

Never drink acidic water.

B e f o r e U s a g e

Safety Precautions  and Warnings

4

5

Summary of Contents for NMP-5000T

Page 1: ... the products such as use in any manner for which the product was not originally intended This product is subject to changes that enhance its performance without prior notification If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard This appliance is not intended for use by persons including children with...

Page 2: ...izer Please read all safety warnings and this User Manual carefully before using this product to ensure proper product usage Keep the manual handy for easy reference I ntendedUse This device creates functional alkaline ionized water It changes the properties of regular tap water through the use of electrolysis Following are the changes normal tap water undergoes via this process We are not respons...

Page 3: ...all amount near a neutral pH level for the first week This will give the body time to adjust to functional water during the detoxification period See Welcome Guide for full details on getting started 3 If you notice any negative effects from drinking functional water stop drinking the functional water immediately and consult your primary care physician about changes in your body s pH level 4 If yo...

Page 4: ...use in areas of high humidity and or high temperature Usage Install the drain faucet near sink and adjust the position of drain faucet to drain away to the sink Make sure the drain faucet is positioned lower than the unit Do not discharge water over 1 hour Ifthe unit won t be used for a long time shut off the valve and unplug the power cord If you hear strange noises smell a burning odor or see sm...

Page 5: ...ute cycles twice weekly This will help to maintain a clean chamber It is normal for condensation to be present on the unit during humid summer months If condensa tion persists despite weather conditions unplug the power cord and refer servicing to qualified service personnel Turn off Cleaning Do not store the unit near chemicals food metals or medication Do not spray water on the main unit Do not ...

Page 6: ... Time function is displayed Filter replacement cycle This unit features a filter life cycle display and voice announce ments designed to let you know when it is time to change the filters Every 6 months is best for optimal performance Touch LCD display color backlight The color back light on the LCD display allows you to distinguish alkali water from acidic water Advanced water purification system...

Page 7: ...izer Faucet Diverter pH Testing Solution Bottle 8 2 ft 2 5 m of Hose Tube Suction Cup Assortment of Connectors and Rubber Washers Adjustable Wrench Utility Scissors Plumb er s Tape Rear View Hanging Groove RearCase PowerCord Bottom View WaterInflow Water Outflow Wrench 1 5 6 4 7 2 1 2 3 2 3 1 Front View Water Outlet Unit LCD Display Front Cover Door Case FrontCase Water Outlet Tube JOG Dial Model ...

Page 8: ... colors are as follows Alkaline level 1 Light Alkaline water Alkaline level 2 Medium Alkalinewater Alkaline level 3 Strong Alkaline water Purify water Creates purified water Acidic level 1 Non Drinkable Acidic level 2 Non Drinkable Turbo mode Non Drinkable 1 Standby screen 2 Water Outflow screen 3 Display color Backlight of LCD display will match the pH level color according to water pH level bein...

Page 9: ...size connector and rubber washer included Whenconnecting the diverter or adapterto the faucet be sure to use plumbing pipe thread seal tape not included to preventleaks If necessary connect the faucetdiverter with the appropriate connector tothe faucet Be sure all connections are secure but do not overtighten them Purchaseeither an under sink installationkit not included or purchasea T connection ...

Page 10: ... or under sink T connection where the diverter or T connection will be installed Cut enough hose to allow connection from the rear of the unit to the water supply either faucet diverter or under sink T connection Note Keep the length under 16 feet 5 meters from the unit to the faucet You may need a pressure pump or larger size hose if the pressure is too low Be sure to leave a few extra inches cen...

Page 11: ...se a fixed amount of water 0 5ℓ 1 0ℓ 1 5ℓ 0 5 1 0 1 5 release Select a desired water mode Water outflow stops automatically Fixed quantity discharge function is released after water comes out Touch the QTY C button Select the fixed amount of water you need by turning the jogdial Clockwise Increasing by 100ml Max 5L Counterclockwise Decreasing by 100ml Min 200ml Push the discharge level youneed Aut...

Page 12: ...essing the SET icon on the LCD for 3 seconds beeps 2 times Voice says System setup mode Press the fixed quantity discharge icon for 3 seconds beeps 2 times The mode AM Hour Minute will be changed by selecting the fixed quantity discharge icon in this sequence Press F1 or F2 to set the time Adjustable by Jog dial Once setup is complete press the fixed quantity discharge icon for 3 seconds beeps 2 t...

Page 13: ...ne Secondary Filter YT20 2nd Filter Recommended filter replacement cycle 951 0 gallons 3 600 L Every 6 months 2nd Filter Fine artificial film filters contaminated materials including ordinary bacteria while maintaining essential minerals in the water Cleaning Function Customer Serviceable Parts Other Icon Display Customer Serviceable Parts Customer Serviceable Parts Cleaning Function Performed dur...

Page 14: ...n reengage the water supply and switch the unit back on Close Open Replace the target filter After replacing the filter press the F1 icon for 3 seconds Selected filter is initialized and beeps twice Voice announcement 1st Filter initializing was performed Next press the F2 icon for 3 seconds Selected filter is initialized and beeps twice Voice announcement 2nd Filter initializing was performed Fil...

Page 15: ...INK these types of waters DO NOT Use the TURBO function in a manner other than directed While operating the TURBO function the machine will automatically stop dispensing water after 5 minutes This feature prevents accidental overflowor flooding Model Number NMP 5000T NMP 7000T NMP 9000T NMP S11T NMP S13T Electrolytic Cell Quantity of Poles 5 7 9 11 13 Power Consumption Max 220W TURBO Function O Pr...

Page 16: ...duce amount ofrawwater Check ifamount ofdrained wateris small Contact us Request after salesservice Filter replacementicon remains on evenafter filter has beenreplaced Check ifthe filter flow rateis initiated Initialize filter flow rate System setting mode or Requestservice Unit stops duringuse Check ifthe operating timeexceeds 15 min Turbo 5 min Unit stops automaticallyafter 15 min Unitleaks Chec...

Page 17: ...Tyent Water is the First People choice all around the World 33 34 33 32 28 ...

Page 18: ...Incomparable certifications Throughout the world Incomparable Certifications Throughout the World With Multiple Languages Supported 35 36 35 34 ...

Page 19: ...Thank you 4 19 21 Bourke Rd Alexandria NSW 2015 TEL 1300 665 636 Website www tyentaustralia com au Tyent Australasia PTY LTD Thank You Thank You 37 38 37 36 ...

Reviews:

Related manuals for NMP-5000T