5
STEP 6:
Route CAT5/6 cable from the antenna into the building. Al-
ways create a strain relief near the antenna so the cable is not pulling
directly on the antenna. Use the CAT5/6 strain relief hook feature built
into the housing back fin. The Ethernet spec allows for a maximum ca-
ble length of 100 meters or about 328 feet.
STEP 7:
Connect a CAT5/6 cable from your com-
puter, switch or router to the LAN port on the
desktop PoE inserter. Connect the CAT5/6 from
the antenna to the POE port on the desktop PoE
inserter. Plug the desktop PoE inserter into a
surge protected AC power source to power up the
EZ
-
Go
®
. NOTE: The EZ
-
Go
®
LT+ will operate
from 12V to 24V.
CAUTION:
Applying a voltage higher than 24V will damage the unit and
void the warranty. Do not plug the antenna directly into a standard
Active PoE port which may operate at voltages of 48V or higher.
Software Settings
1. There is an HTML management system built into every EZ
-
Go
®
unit
which is accessed thru a standard web browser. The unit can communi-
cate thru the CAT5/6 Ethernet cable connection or thru the wireless
bridge connection, so you can manage remote units from a single loca-
tion.
NOTE:
The device will usually go into a 1
-
2 minute reboot cycle when
clicking on SAVE & APPLY CHANGES. During this time it will be unre-
sponsive. The unit will beep once when it reboots and beep twice when
it is ready.
2.
IP ADDRESS:
Default IP address for the EZ
-
Go
®
is 192.168.1.239.
To access the EZ
-
Go
®
, your computer IP address must be on the same
subnet ie; 192.168.1.xxx. The EZ
-
Go
®
ships with DHCP client enabled
so if the unit has access to your network it will get its IP address auto-
matically from your network. To find the units IP address use the Dis-
covery Tool. We recommend after everything is working to your satis-
faction that you assign a unique static IP to the unit so you always know
how to access the units on your network. The IP address setting can be
changed at NETWORK | INTERFACES | EDIT LAN | PROTOCOL
3.
CHANNELS:
The default channel is set to AUTO. The EZ
-
Go
®
client
unit will automatically find the channel of the connected AP if the SSID
(ie;
“
EZ
-
Bridge
”
) and Wireless encryption settings are the same on AP
and Client. Also on the AP if Mac Address Verification is turned on, it
must be disabled or the new client MAC address needs to be in the al-
lowed list.
4.
SECURITY:
Security is pre
-
configured with system passwords and
WPA2 encryption pre
-
set. This is so that you can setup a link to an ex-