Tyco Visonic PowerMaster-360 User Manual Download Page 12

Partitions

The control panel includes an optional partition feature. Partitioning is available only if your

installer has enabled the feature. Partitioning allows you to divide the system into three

independently controllable areas with different users assigned to each partition whereby each user

can arm the partition to which they are assigned.
Each user code can be assigned to a combination of up to three partitions, and each partition can

be armed or disarmed regardless of the status of the other partitions within the system. Example:

you can define the garage as partition 1, the basement as partition 2, and the house as partition 3.

Because each partition is independent of other partitions, you can arm or disarm each partition as

required, without altering the states of the other partitions.
Partitions status is indicated as 

P1:X P2:X P3:X

, where each X value indicates a different partition

state as described in the following table:

Table 5: Partition status

R

Ready

N

Not ready

A

Away

H

Home

E

Exit delay

D

Entry delay

-

Not used

Note: 

Remote operation is performed per partition, or per user code defined for a particular

partition, when partitioning is enabled.

A partition is alarmed when receiving an event from an alarmed device assigned to that partition.

Alarmed devices do not affect partitions to which they are not assigned. A siren is common to all

partitions; therefore, an alarm from one or more partitions will activate the siren.

Siren activity in partitions

The following list describes the features of siren activity in partitions:
• For a siren that is common to all partitions, an alarm from one or more partitions will activate the

siren.

• If the Siren per partition feature is disabled by the installer, all sirens will be activated if there is

an alarm in any partition.

• If the Siren per partition feature is enabled by the installer, a siren will be activated if there is an

alarm only in its associated partition or partitions.

• A siren activates exit/entry beeps during exit/entry delay of its associated partition or partitions.
• Overlapping siren activations from different partitions will not cause the duration of the siren to

be extended.

• If the Siren per partition feature is disabled by the installer, a siren alarm in a particular partition

can be stopped only if the user that disarms the system has permissions to the partition in

question.

• A siren that is assigned to common partitions can be disarmed by any user who has permissions

to that common partition.

D-307503 PowerMaster-360 User's Guide

12

Summary of Contents for Visonic PowerMaster-360

Page 1: ...S notifications 9 Operating the alarm system through SMS 10 Periodic testing 10 Replacing the PowerMaster 360 backup battery 11 Replacing batteries in wireless devices 11 Acknowledging keyfob low batt...

Page 2: ......

Page 3: ...private telephones and mobile phones Events can be reported by SMS and email Your installer can determine what type of events will be reported to which destination Note A qualified technician must ch...

Page 4: ...ifferent users assigned to each partition whereby each user can arm the partition to which they are assigned Common areas The system supports areas that are used by two or more partitions Example a re...

Page 5: ...s an abnormal condition D Server connectivity Blue a connection is active between the panel and the PowerManage server Off the panel is not connected to the PowerManage server E Smart home service con...

Page 6: ...rovide homeowners with visual indication of successful command execution and system status Keyfobs The KF 234 PG2 and KF 235 PG2 keyfobs are used to arm and disarm the alarm system for emergency signa...

Page 7: ...sturbance of a perimeter zone will cause an alarm Quick arm away Used to arm away without the need to provide a user code Note the installer should enable this option if required Quick arm home Used t...

Page 8: ...the detectors Pressing the emergency buttons on the keypad When an alarm is initiated the internal control panel s sounder is activated first for a limited period set by the installer this is the abor...

Page 9: ...ile phone numbers The messages can be tagged with a House ID name for example JOHN S HOUSE The following are examples of the reported SMS messages JOHN S HOUSE AWAY JOHN S HOUSE DISARM JOHN S HOUSE PO...

Page 10: ...ST_ code TURN PGM ON PGM_XX_ON_ code P PGM_XX_ON_ code TURN PGM OFF PGM_XX_OFF_ code P PGM_XX_OFF_ code House ID includes up to 16 characters for example JOHN S HOUSE Note There may be some delay in e...

Page 11: ...devices should be consulted for proper battery replacement guidelines to be performed by the installer Note When the low battery message is received the battery should be replaced within 7 days Ackno...

Page 12: ...abled A partition is alarmed when receiving an event from an alarmed device assigned to that partition Alarmed devices do not affect partitions to which they are not assigned A siren is common to all...

Page 13: ...household and make an evacuation plan Draw a floor plan of your home showing two ways out of each room including windows Do not forget to mark the location of every smoke detector Test all smoke detec...

Page 14: ...escape plan It is important to be aware of the escape plan when children are permitted to attend sleepovers at friends homes If they do not have a plan in place offer to help them make one PowerMaster...

Page 15: ...ectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to...

Page 16: ...the Products to the original purchaser only the Buyer against defective workmanship and materials under normal use of the Products for a period of twelve 12 months from the date of shipment by the Sel...

Page 17: ...use the Product or for loss or destruction of other property or from any other cause even if Seller has been advised of the possibility of such damage The SELLER shall have no liability for any death...

Page 18: ...is supplied shall not apply Governing Law This disclaimer of warranties and limited warranty are governed by the domestic laws of Israel Warning The user must follow the Seller s installation and ope...

Reviews: