Operating the alarm system through SMS
The PowerMaster-360 system can respond to SMS commands from any cellular telephone.
The various SMS commands are detailed in the following table.
In this table, <code> means a 4-digit user code and _ means blank space.
Table 4: SMS command list
Command
SMS format
SMS format for partitions
ARM AWAY
AWAY_<code> or AW_<code>
P# AWAY_<code> or
P# AW_<code>
ARM AWAY INSTANT
AWAY INST_<code> or
AWI_<code>
P# AWAY INST_ <code> or
P# AWI <code>
ARM AWAY LATCHKEY
LATCHKEY_<code> or
LK_<code>
P# LATCHKEY_<code> or
P# LK_<code>
ARM AWAY LATCHKEY INSTANT LATCHKEY INST_<code> or
LKI_<code>
P# LATCHKEY INST_<code> or
P# LKI_<code>
ARM HOME
HOME_<code> or HM_<code>
P# HOME_<code> or
P# HM_<code>
ARM HOME INSTANT
HOME INST_<code> or
HMI_<code>
P# HOME INST_<code> or
P# HMI_<code>
DISARM
DISARM_<code> or DA_<code> P# DISARM_<code> or
P# DA_<code>
DEFINE HOUSE IDENTITY¹
HOUSE NAME_<code> <house
ID> or HN_<code> <house ID>
P# HOUSE NAME_<code>
<house ID> or
P# HN_<code> <house ID>
GET SYSTEM STATUS
STATUS_<code> or ST_<code>
P# STATUS_<code> or
P# ST_<code>
TURN PGM ON
PGM_XX_ON_<code>
P# PGM_XX_ON_<code>
TURN PGM OFF
PGM_XX_OFF_<code>
P# PGM_XX_OFF_<code>
¹House ID includes up to 16 characters, for example, JOHN'S HOUSE
Note:
There may be some delay in executing the commands sent through SMS messages if the
PowerMaster-360 panel is communicating at the same time.
Periodic testing
The components of the security system are designed to be maintenance-free as much as possible.
It is mandatory to test the system at least once a week, and after an alarm event, to verify that all
system sirens, detectors, keyfobs, keypads, and other peripherals function properly. Proceed as
described in this section and if there is any problem, notify your installer at once.
The test is performed in four parts as follows:
1. Siren test: Each siren of the system is automatically activated for 3 seconds (outdoor sirens
with low volume). In addition, the system tests the siren of enrolled smoke sensors.
2. Temp/light test: For devices with temperature sensing, the panel displays the temperature of
each zone in Celsius or Fahrenheit. For devices that have both temperature and light sensing,
the panel displays the temperature and light intensity of each zone.
D-307503 PowerMaster-360 User's Guide