Tyco NEKA Series Installation Instructions Manual Download Page 9

NEKA

9

Wiring

Use shielded cable only, with one end connected to the control panel negative and the other left free.

T.

Description

SPK

Loudspeaker connection terminals.

AS
ASG

Tamper signalling terminals: when tamper signalling is set to normal mode, these terminals open when the cover
or innerplate is removed, or when siren is pulled from the wall, or when the foam tamper is detected (

NEKA-F

and 

NEKA-FS

 only).

FT

Foam tamper signalling terminal (

NEKA-F

 and 

NEKA-FS

 only): open-collector normally closed to ground, it

opens when at least 30 seconds has been elapsed from interruption of the device infrared barrier.

This terminal is disabled when tamper signalling is in automatic mode (

) and siren is automatically

activated by foam tamper too (

).

G

Trouble signal terminal: open-collector normally closed to ground, opens for low battery and battery trouble
(

NEKA

 and 

NEKA-F

 only), loudspeaker trouble, flash bulb damage (strobe board not present).

F

Alarm activation terminal with programmable polarity (optical signalling only).

A

Alarm activation terminal with programmable polarity (acoustic signalling only).

AF

Acoustic and optical signalling activation terminal, with programmable polarity.

+N

Power supply (positive) and alarm terminal. 13.8 V must be applied to this terminal for the battery charge. If this
voltage fails (wire cutting or alarm) the siren go into alarm status (acoustic and optical signalling).

M

Negative supply terminal and ground of the internal circuit.

Table 3 – Terminal description.

Summary of Contents for NEKA Series

Page 1: ...NEKA Outdoor Self Powered Siren Installation Instructions...

Page 2: ...nt and ensures uniform sound distribution Robust construction and state of the art technology greatly extend application flexibility whilst microprocessor supervision of the battery charge NEKA and NE...

Page 3: ...NEKA 3 Figure 1 Parts a cover b innerplate c backplate e Electronic board 2 1 1 2 11 3 4 5 6 7 8 9 10 11 12 11 21 20 19 18 17 15 11 14 13 16 a b c d...

Page 4: ...ren and other types of signalling depending on requirements through N AF A or F terminals In automatic mode the siren independently activates the acoustic and optical signalling for tamper events AS a...

Page 5: ...If troubles are not present the inhibition of siren activation is delayed between 30 seconds and 2 minutes to prevent this function being used to tamper the siren In this phase anti foam device can be...

Page 6: ...the interrupted alarm signal is still present when the priority alarm terminates due to timeout or restoral it activates the loudspeaker and strobe flash in accordance with its configuration If the i...

Page 7: ...p scale modu lation LF N Up and down scale modulation LF AF Up and down scale modulation HF A Multitone HF S Tamper automatic mode Up scale modula tion LF N Up and down scale modulation HF AF Up scale...

Page 8: ...0 Fix the wall tamper plate through the hole 16 without tightening the screw too much in order not to break the stop tabs 11 Set the siren operating mode by means of the jumpers 6 and 7 and make the c...

Page 9: ...n tamper signalling is in automatic mode and siren is automatically activated by foam tamper too G Trouble signal terminal open collector normally closed to ground opens for low battery and battery tr...

Page 10: ...3 Automatic mode A control panel B siren Automatic mode with independent management of foam tamper NEKA F NEKA FS only If foam tamper have to be managed by the control panel jumpers position must be...

Page 11: ...ce on tamper line Normal mode with independent management of foam tamper NEKA F NEKA FS only If foam tamper have to managed by control panel independently from the siren tamper jumper positions must b...

Page 12: ...or NEKA F NEKA FS sirens only Figure 7 Normal mode when the siren is not latest device on tamper line A control panel B siren D to previous device on tamper line E to next device on tamper line Other...

Page 13: ...siren power supply and siren battery charg ing Figure 9 Wiring to activate the siren by means an open collector output that closes to ground on alarm A control panel B siren Figure 10 Wiring to activa...

Page 14: ...may be low 2 The flash may be out of order 1 Replace the battery if necessary 2 Change the flash bulb or call the installer The flash functions but the loud speaker is silent 1 More than the maximum a...

Page 15: ...nsions WxHxD 208x252x98 mm Weight without battery 2300 g Available sounds Type of sound Frequencies Period Sound level at 3 m Multitone 1108 Hz for 200 mS 1244 Hz for 180 mS 1396 Hz for 150 mS 1567 Hz...

Page 16: ...om index php o environment htm Waste electrical and electronic equipment WEEE directive Hereby Bentel Security Srl declares that the product NEKA NEKA F NEKA FS complies with standards EN 60950 EN 610...

Page 17: ...NEKA 17...

Page 18: ...18 Outdoor Self Powered Siren...

Page 19: ...NEKA 19...

Page 20: ...nical specifications of this product without prior notice BENTEL SECURITY s r l Via Gabbiano 22 Z Ind S Scolastica Corropoli TE Italy tel 39 0861 839060 Fax 39 0861 839065 infobentelsecurity tycoint c...

Reviews: