![Tyco NEKA Series Installation Instructions Manual Download Page 10](http://html1.mh-extra.com/html/tyco/neka-series/neka-series_installation-instructions-manual_1185961010.webp)
10
Outdoor Self-Powered Siren
Automatic mode
For siren basic operation are required two wires only, as shown in figure 3: the control panel (A) must have a terminal (
+N
) where
13.8 V voltage (minimum 600 mA) is present on standby and no voltage in alarm; the control panel cannot detects the siren tamper,
and foam tamper (
NEKA-F
and
NEKA-FS
only) but the siren automatically activates for those events.
Figure 3 – Automatic mode: A) control panel; B) siren.
Automatic mode with independent management of foam tamper (
NEKA-F
/
NEKA-FS
only)
If foam tamper have to be managed by the control panel, jumpers position must be as shown in figure 4, and
FT
terminal of the
siren (B) must be connected to an input line of the control panel (A) that is on standby when connected to ground and in alarm
when floating (
Z
terminal in the figure).
Figure 4 – Automatic mode with independent management of foam tamper: A) control panel; B) siren.
AF
+N
AS SPK
ASG
FT
G
F
A
+N
A
B
NEKA-F
NEKA-FS
NEKA
AF
+N
AS SPK
ASG
FT
G
F
A
+N
Z
A
B
NEKA-F
NEKA-FS