General Information
2G Alarm Communicator Installlation Manual
6
G
ENERAL
I
NFORMATION
All versions of the GSM and Ethernet Alarm Communicator, operate on a GSM network and are housed inside the Self Contained
Wireless Alarm System Model SCW9055/9057. The Communicators use an Internal Antenna only.
Each version of Alarm Communicators covered by this Installation Manual are described below:
GS2055:
A High Speed Packet Access/Global System for Mobile (GSM) wireless Alarm Communicator that sends alarm communication to
Sur-Gard System I, II, III (SG-DRL3IP), and IV (SG-DRL4IP) central station receivers via a GSM digital cellular network.
TL255GS:
Is a dual-path Cellular/Ethernet Alarm Communicator that sends alarm communication to Sur-Gard System I, II, III, and IV
central station receivers through Ethernet/Internet or a GSM digital cellular network.
The dual path Communicator can be used as either a backup or primary Communicator. The Communicator supports Internet Protocol
(IP) transmission of panel and internal events over Ethernet/Internet and/or GSM.
For North America the following model names are available:
GS2055-NA
and
TL255GS-NA
.
CAUTION
:
• Do not stay close to the equipment during device operation and to do not touch any exposed wires and other conductive surfaces,
• Recycle the battery according to the local rules and regulations.
NOTE:
Prior to installation of the
GS2055
or
TL255GS
Communicator, confirm with your local carrier that the GSM network is avail-
able and active in the area where the Communicator will be installed, and that the location provides a radio signal strength that
is adequate for uninterrupted service.
F
EATURES
UL/ULC I
NSTALLATION
R
EQUIREMENTS
• For ULC Residential fire and burglary applications the
GS2055/TL255GS
can be used as primary communication channel via either
Cellular or Ethernet (as applicable) or as a back-up in conjunction with the Digital Alarm Communicator Transmitter (DACT). Test
transmission every 24hours shall be enabled on each channel.
• For UL Residential fire and burglary applications the
GS2055/TL255GS
can be used as primary communication channel via either
Cellular or Ethernet, or as a back-up in conjunction with the DACT. (30 day test transmission is required on each channel).
C
OMMUNICATOR
F
REQUENCY
B
ANDS
FOR
N
ORTH
A
MERICA
C
OMMUNICATOR
T
ECHNICAL
S
PECIFICATIONS
• 128-bit Advanced Encryption Standard (AES) encryption via GSM and Ethernet/Internet.
• Activating, initializing and remote programming through Connect 24.
• Back up or primary GSM alarm communication.
• Does not require an external GSM antenna.
• Ethernet LAN/WAN 10/100 BaseT (TL255GS only).
• Full event reporting to central station.
• RS422 is the connection for interactive hub/gateway.
• Fully redundant Ethernet/Internet and GSM Dual-path Alarm Communication (TL255GS only).
• Individual Ethernet and/or GSM Periodic test transmission.
• 2-way audio (listen-in feature) provided over Cellular.
• Integrated call routing.
• Remote Firmware upgrade capability of the Communicator and Panel Firmware via Ethernet and/or GSM radio.
• Dual-Band Operation: 850 MHz, and 1900 MHz. (North America only).
• CID and SIA format reporting.
• Subscriber Identity Module (SIM) card included with Communicator. (North America only).
• Supervision heartbeats via GSM and/or Ethernet/Internet.
Table 2: 2G Frequency Bands - North America and International
Transmit Direction
Cellular 850 North America
PCS 1900 North America
Transmit Frequency
824 MHz to 849 MHz
1850 MHz to 1910 MHz
Receive Frequency
869 MHz to 894 MHz
1930 MHz to 1990 MHz