background image

4

Installation of GS3070-CF

CONNECT 24 Enrollment Information

Only authorized dealers can enroll a 3G3070-CF with CONNECT 24. Dealer application forms and
additional information on the CONNECT 24 Voice Response Unit can be found at the CONNECT 24 web
site www

www

www

www

www.connect24.com

.connect24.com

.connect24.com

.connect24.com

.connect24.com. Please contact CONNECT 24 at the number below for assistance:

USA 1-888-251-7458

USA 1-888-251-7458

USA 1-888-251-7458

USA 1-888-251-7458

USA 1-888-251-7458

CANADA 1-888-955-5583

CANADA 1-888-955-5583

CANADA 1-888-955-5583

CANADA 1-888-955-5583

CANADA 1-888-955-5583

NOTE: Step 1 should be completed before powering the 3G3070-CF unit.

STEP 1 - Initialize the 3G3070-CF with Connect 24
VRU Enrolment

Call the VRU at the toll-free number: 1-866-910-3865. Follow the voice prompts and enter in your profile
number, installer ID number, installer PIN number and SIM number.  Ensure all information is available
before calling the VRU. It is recommended that the radio initialization be performed at least 24 hours in
advance of installation to ensure SIM activation will be complete.

NOTE: For UL Commercial Fire listed products the supervision heartbeat shall be enabled.

WEB Enrolment

If you have credentials for www.connect24.com, you may also initialize the 3G3070 via the web. Please
check with your Connect 24 Master Reseller or Connect 24 Customer Service for more details.

STEP 2 - Determine Best Signal Location

1. Remove the screws and the front cover of the 3G3070-CF metal enclosure [1

1

1

1

1].

2. Fit the antenna [2

2

2

2

2] (ensure that the bolt [3

3

3

3

3] is fastened tightly).

3. Connect the antenna to the 3G Radio [5

5

5

5

5] and ensure the connector is secure.

NOTE: Before inserting or removing the SIM card, please ensure the unit is powered down.

NOTE: Before inserting or removing the SIM card, please ensure the unit is powered down.

NOTE: Before inserting or removing the SIM card, please ensure the unit is powered down.

NOTE: Before inserting or removing the SIM card, please ensure the unit is powered down.

NOTE: Before inserting or removing the SIM card, please ensure the unit is powered down.
4. Ensure the SIM card is placed in its socket [6

6

6

6

6].

5. Power up the 3G3070-CF module [4

4

4

4

4] and check signal strength on status LEDs [7

7

7

7

7].

• Use a DC power source rated 12V/0.7A connected to +/- 12V terminals [9

9

9

9

9]

• Allow unit to power up
• The green LEDs will indicate the signal strength. The bottom green LED must be ON

ON

ON

ON

ON for the location

to be acceptable.  Please refer to the “Status LEDs” section for more information.

6. Power down the 3G3070-CF by removing the DC power source.

STEP 3 - Connect the 3G3070-CF

1. Using the cabinet, mark the 4 screw locations then drill the anchor screw holes.

NOTE: Check for cable conduits and water pipes before drilling.

2. Using anchor screws (not included), mount the cabinet to the wall.
3. Run the cables, then pull them through the cable entry or the knockouts provided.
4. Complete the connections to the terminal blocks [9

9

9

9

9], [11

11

11

11

11]. 

Ensur

Ensur

Ensur

Ensur

Ensure power and T

e power and T

e power and T

e power and T

e power and Telco cir

elco cir

elco cir

elco cir

elco circuit connections

cuit connections

cuit connections

cuit connections

cuit connections

are made only after the cabinet has been secured to the building or structure and has been connected

are made only after the cabinet has been secured to the building or structure and has been connected

are made only after the cabinet has been secured to the building or structure and has been connected

are made only after the cabinet has been secured to the building or structure and has been connected

are made only after the cabinet has been secured to the building or structure and has been connected
to the protective earth ground

to the protective earth ground

to the protective earth ground

to the protective earth ground

to the protective earth ground. Descriptions of the terminals can be found in the “Connecting the
3G3070-CF” section.
5. Using the 4 screws, reattach the front cover securely to the cabinet [1

1

1

1

1].

NOTE: Please refer to Figures 2 and 3 at the end of this manual for wiring diagrams.

NOTE: When installing the 3G3070-CF as a stand alone communicator in conjunction with a fire
panel that has an integrated dual telephone line dialer (dual DACT), install only one of the
telephone lines from the dual line dialer to the 3G3070-CF communicator. The second telephone
line of the dual line dialer cannot be connected to the input of the 3G3070-CF and must be
disabled in order to maintain correct functionality of the communication system. Please contact
the panel vendor for details on how to disable the second telephone line.

firealarmresources.com

Summary of Contents for DSC 3G3070-CF

Page 1: ...t use and function and information on the limitations as to liability of the manufacturer Installation Manual v3 5 3G3070 CF Fire Alarm Communicator for central station service fire alarm commercial R...

Page 2: ...onnections Description 5 Status LEDs 6 Operating Modes 7 Inputs Activation Mode 8 Activating the Outputs 8 Contact ID Events Description 8 Event Codes 8 Swinger Shutdown 9 Hardware Default 9 Connect 2...

Page 3: ...chnical Specifications Input Voltage 120V 60HZ 0 3A Standby Voltage 12V 7Ah Standby Time 24h NSC plus 5 minutes alarm Standby Battery Sealed rechargeable type replace every 3 5 years Low Battery Troub...

Page 4: ...munication technology 5 minute supervision Heartbeat sent to supervising station every 97 seconds 2 Back up communicator line for a DACT dual communication technology no heartbeat sent Alarm signals m...

Page 5: ...cial Fire Installations connections between the fire alarm control panel outputs telephone interface Tip Ring or output relay contacts and GS3070 CF inputs Tip Ring Z1 Z4 shall be run in mechanical pr...

Page 6: ...atus LEDs 7 7 7 7 7 Use a DC power source rated 12V 0 7A connected to 12V terminals 9 9 9 9 9 Allow unit to power up The green LEDs will indicate the signal strength The bottom green LED must be ON ON...

Page 7: ...t up to trigger events Refer to Inputs Activation Mode section for details 12V 19 12V 20 Device Power Supply 12V 19 12V 20 Device Power Supply 12V 19 12V 20 Device Power Supply 12V 19 12V 20 Device Po...

Page 8: ...ashes 4 flashes 4 flashes 4 flashes Insufficient Signal Strength poor location 5 flashes 5 flashes 5 flashes 5 flashes 5 flashes Connect 24 Configuration SMS Failure improper VRU programming When the...

Page 9: ...from the receiver Once the conditions for a failed attempt are met the 3G3070 CF connects the panel to the wireless network to communicate the events When the 3G3070 CF switches the line it stays in t...

Page 10: ...ne device OUTPUT 2 W OUTPUT 2 W OUTPUT 2 W OUTPUT 2 W OUTPUT 2 Wir ir ir ir ireless Module or Network T eless Module or Network T eless Module or Network T eless Module or Network T eless Module or Ne...

Page 11: ...e h t m e d o m e h t t a r o t c e n n o c e h t f o d n e e h t n o b m u h t y l t n e G r o t c e n n o c d n a m e d o m e h t n e e w t e b r e v i r d w e r c s a m o r f r o t c e n n o c e h...

Page 12: ...ntact ID over the telephone line t h g i L n e e r G t h g i L n e e r G t h g i L n e e r G t h g i L n e e r G t h g i L n e e r G s u t a t S s n a e m t i t a h W s n a e m t i t a h W s n a e m t...

Page 13: ...n i C A e h t o t d e t c e n n o c s i r e m r o f s n a r t C A e h t t a h t e r u s n E y l p p u s r e w o p e h t n o s l a n i m r e t e h t o t d e t c e n n o c s i y l p p u s r e w o p e h...

Page 14: ...g i l d e r F C 0 7 0 3 G 3 e h t f I e d i u g s i h t n i t r a h c s u t a t S l a r t n e c e h t t a d e v i e c e r e r a s l a n g i s o N s i n o i t i d n o c e l b u o r t o n t u b n o i t...

Page 15: ...Phone line connection is required only for back upconfigurations Instand aloneapplica tions no other communication technology is required for Fire Alarm Monitoring Refer to Fig 4 for wiring details Th...

Page 16: ...puts are typically used to interface with fire alarm panels that do not have a dialer interface and use the fire alarm fire supervisory or fire trouble output relay contacts to send the events to the...

Page 17: ...3 Z4 12V NOTES 1 Program the Control Panel s input Zone Point as 24h Supervisory type with the keypad only annunciation when activated 2 A supervision relay DSC model RM 2 can be used as indicated in...

Page 18: ...ll areas the sum of RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to a line as determined by the total RENs contact the local Telephone Company For produ...

Page 19: ...terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may terminate...

Page 20: ...est extent of the law including pursuit of criminal prosecution wherever necessary All trademarks not owned by Tyco International Ltd are the property of their respective owners and are used with perm...

Reviews: