![Tyco Bentel Security PowerG BW-SRO Installation Manual Download Page 3](http://html1.mh-extra.com/html/tyco/bentel-security-powerg-bw-sro/bentel-security-powerg-bw-sro_installation-manual_1185954003.webp)
2.2. Enrollment
Refer to the BW panel's Installer's Guide and follow the procedure under the
"02:ZONES/DEVICES"
option of the Installer Menu. A general description
of the procedure is provided in the following flow chart.
Step 1
Step 2
Step 3
Step 4
Step 5
Enter the Installer menu
and select
“02:ZONES/DEVICES”
Select
"ADD NEW
DEVICE"
See Note 1
Enroll the device or enter
the device ID
Select the desired siren
number for the new siren
Configure Location and
Zone Type Parameters
02:ZONES/DEVICES
ð
ADD NEW DEVICES.
6
MODIFY DEVICES
ð
ENROLL NOW or
ENTR ID:XXX-XXXX
ð
SR1:Siren Outdoor
ID No.410-XXXX
ð
SR1.LOCATION
SR1.ZONE TYPE
SR1.SET CHIME
ð
Step 6
Step 7
Step 8
Notes:
Enter PARTITIONS.
See Note 2
Assign partitions to the siren
by pressing the
,
and
buttons
on the panel
Select the "DEV
SETTINGS" option and
refer to the section below to
configure the siren
parameters.
1.
If the siren is already enrolled, you can
configure the siren parameters and assign
partitions via the
“Modify Devices”
option – see Step 2.
2.
PARTITIONS will appear only if
PARTITIONING was previously enabled in
a panel that supports the Partitioning
feature (for further details, see
"Partitioning" in the BW Installer Guide).
3.
When there is an alarm, the siren will
sound regardless of partition assignment.
SR1.PARTITIONS
ð
SR1:P1
n
--
P2 ....P3
n
ð
SR1:DEV SETTINGS
ð
ð
means scroll
ww
and select
OK
2.3. Configuring the Siren Parameters
Enter the
DEVICE SETTINGS
menu and follow the configuration instructions for the BW-SRO outdoor siren as described in the following table.
Option
Configuration Instructions
STROBE ALARM
Here you determine whether or not to activate the strobe alarm, and if activated, whether to activate the strobe until the alarm
system is disarmed, or, for the programmed period of time (see "Siren Configuration" section in the control panel Installer
Guide).
Optional settings:
Timer limited
(default),
Disabled
and
Until Disarmed
EXIT-ENTRY Beeps
Here you determine whether or not to activate the exit – entry beeps, and if enabled, whether to activate in HOME or AWAY
mode.
Optional settings:
Disabled
(default),
Disabled & Home
and
Enabled
.
SQUAWK
Here you determine whether or not to enable the squawk, and if enabled, whether to activate the sounder only, or, the
sounder and strobe simultaneously.
Optional settings:
Disabled
(default),
Sounder only
,
Strobe only
and
strobe
.
SOUNDER
VOLUME
Here you determine the volume level of the sounder.
Optional settings:
Volume HIGH
(default),
Volume LOW
and
Volume MID
.
ACTIVITY LED
Here you determine whether or not the LED will be activated to indicate that the siren is operating.
Optional settings:
Disabled
(default) and
Enabled
.
AUTO TAMPER
ALRM
Here you determine whether or not the siren alone will sound a tamper alarm when there is no communication between the
siren and the control panel.
Optional settings:
Disabled
(default) and
Enabled
.
FRZR TRBL BEEP
Turn on or turn off freezer trouble beeps for indoor or outdoor sirens. Freezer trouble beeps occur every minute.
Optional settings:
on
(default) and
off
.
D-308696 BW-SRO Installation Guide
3