5
Mounting the 12MP Pro Fisheye Camera
To tilt mount the Illustra 12MP Pro Fisheye camera, complete the following steps:
1. To remove the front cover of the camera, use a Torx wrench to unscrew the two screws.
Figure 3
. Site of screws on camera front cover.
2. Attach the camera base assembly to the tilt plate using the supplied screws.
Figure 4
. Camera base assembly with tilt plate attached
3. Remove the plastic film from the lens.
4. Secure the camera base to the M3 threaded inserts that are fitted in the tilt plate, using the M3 fasteners
supplied in the installation kit. Ensure that the camera is rotated to a horizontal plane and that it is centered
on the tilt plate. Refer to Table 1 for information on securing the tilt plate to the wall box.
Figure 5.
Screw sites on camera body
5. Thread the camera network cable into the opening on the back plate and align the top side of the camera
with the top of the back plate. For the Pro 12MP Fisheye Outdoor camera, Illustra recommends sealing the
cables as described in the
Illustra Pro 12MP Fisheye Quick Start Guide.
6. To adjust the angle of the tilt on the tilt mount, loosen the locking screw at the bottom of the mount and
slide the lock to the desired point on the slot. Tighten the locking screw when the tilt mount is at desired
angle.
7. Replace the camera cover on the camera and secure it by tightening the two screws using the Torx wrench.