PowerSeries Neo Installation Guide
Aux Loading and Battery Selection
HS2128/HS2064/
HS2032/HS2016
Board current draw mA
UL Residential Burg
ULC Residential Burg
UL Commercial Burg
UL Resi Fire
UL Home Health Care
ULC Resi Fire
ULC Com Burg
ULC Fire Monitoring
EN50131
Grade 2/Class II
Max AUX (NSC) current
loading
0.7A
0.7A
0.5A*
0.5A
480mA
Max BELL (Alarm) current
loading
0.7A
0.7A
0.7A
0.7A (no local alarm
notification allowed, only
remote transmission to SRC)
0.7A
UL/ULC Listed enclosure
PC500C
PC5003C
CMC-1
PC4050CAR
PC5003C
PC5003C
PC4050CR (red/transfomer
mounted inside)
PC5003C
Power UC1
Transformer requirements
16.5V/40VA (plug in type)
PTC1640U (USA)
PTC1640CG (CAN)
FTC1637 (cUL listed)
16.5V/37VA (Hardwired
type, mounted inside the
enclosure or outside using
electrical box)
16.5V/40VA (hardwired
type, mounted inside the
cabinet)
Battery Capacity requirements
7Ah
7Ah
14Ah (2 x 7Ah in
parallel)
14Ah (2 x 7Ah in parallel)
7Ah
Standby Time
UL: 4 hours
ULC: 24 hours
4 hours
24 hours
24 hours
12 hours
Alarm time
4 minutes
15 minutes
4 min (UL resi fire)
5 min (Home Health
Care and ULC Resi Fire)
5 minutes (Alarm
Transmission only)
N/A
Recharging current setting
mA, 700mA
mA, 700mA
mA, 700mA
480mA, 700mA
480mA, 700mA
(*) For UL Residential Fire Installations, using hardwired CO Alarm Detectors, the maximum discharge current shall be limited to 250mA to ensure 24h standby
operation followed by 4 minute CO alarm notification then followed by an additional 12h of CO Alarm notification.
EU Compliance Statement
This product meets the requirements of Class II, Grade 2 equipment as per EN50131-1: 2006+A1:2009, EN50131-3:2009, EN50131-6:2008+A1:2014 (Type A),
EN50136-1-1:1997, EN50136-2-1, EN50136-2-3 (ATS2) Standards.
This device is suitable for use in systems with the following notification options.
l
A (use of two warning devices and internal dialer required
l
B (self-powered warning device and internal dialer required
l
C (use of DSC compatible alternate communicator in back-up or redundant mode)
l
D (use of DSC compatible alternate communicator with encryption enabled required.)
For EN50131 compliant installations only the intrusion portion of the alarm system has been investigated. Fire Alarm and Auxiliary (Medical) Alarm functions were
not included in the evaluation of this product under the requirements of the above mentioned standards.
Additional features implemented for EN 50131 Grade 2:
l
Fire alarm and CO alarm annunciation
l
Auxiliary (medical) alarm annunciation
l
Optional feature implemented for EN 50131 Grade 2:
l
Removal from mounting tamper detection for non wire-free components
The models HS2128, HS2064, HS2032, HS2016 Control Panel has been certified by Telefication according to EN50131-1:2006 +A1:2009, EN50131-3:2009,
EN50131-6:2008+A1:2017 (Type A) and EN50136-1:1997 (ATS2) for Grade 2, Class II.
Compliance labeling should be removed or adjusted if non-compliant configurations are selected.
This product (HS2128/HS2064/HS2032/HS2016) is in conformity with the Electromagnetic Compatibility Directive 2014/30/EU, the Low Voltage Directive
2014/35/EU, and the ROHS3 Directive 2011/65/EU.
The product is labelled with the CE mark as proof of compliance with the applicable European Directives. Also a CE declaration of conformity (DoC) for this
product can be found at www.dsc.com under Agency Listings section.