Tyco Fire Product Gem TY-B Instruction Manual Download Page 2

Page 2 of 8

TFP151

2

4

5

6

PENDENT

CROSS SECTION

(55,6 mm)

2-3/16"

(38,1 mm)

1-1/2"

PLATE SEATING

ESCUTCHEON

7/16" (11,1 mm)

NOMINAL

MAKE-IN

FLATS

WRENCH

SURFACE

1

3

NPT

1/2"

RECESSED PENDENT

UPRIGHT

2-7/8" (73,0 mm) DIA.

(11,1 mm)

NOMINAL

MAKE-IN

7/16"

RECESSED

STYLE 10

ESCUTCHEON

(55,6 mm)

2-3/16"

1/2" NPT

DEFLECTOR

SSU

SSP DEFLECTOR

**

**

*

*

*

FIGURE 1

STANDARD RESPONSE SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS

5.6 K-FACTOR, 1/2 INCH NPT

1 - Frame
2 - Button

3 - Sealing

Assembly

4 - Bulb
5 - Compression

Screw

6 - Deflector

*

Temperature rating is indicated on deflector or adjacent to

orifice seat on frame.

**

Pipe thread connections per ISO 7/1 can be provided on

special request.

2

4

5

6

PENDENT

CROSS SECTION

(58,7 mm)

2-5/16"

(39,7 mm)

1-9/16"

PLATE SEATING

ESCUTCHEON

1/2" (12,7 mm)

NOMINAL

MAKE-IN

SURFACE

1

3

NPT

3/4"

RECESSED PENDENT

UPRIGHT

(12,7 mm)
NOMINAL

MAKE-IN

1/2"

RECESSED

STYLE 40

ESCUTCHEON

(57,2 mm)

2-1/4"

3/4" NPT

DEFLECTOR

SSU

SSP DEFLECTOR

7

FLATS

WRENCH

2-7/8" (73,0 mm) DIA.

**

*

**

*

*

FIGURE 2

STANDARD RESPONSE SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS

8.0 K-FACTOR, 3/4 INCH NPT

1 - Frame
2 - Button

3 - Sealing

Assembly

4 - Bulb
5 - Compression

Screw

6 - Deflector
7 - Ejection

Spring

*

Temperature rating is indicated on deflector or adjacent to

orifice seat on frame.

**

Pipe thread connections per ISO 7/1 can be provided on

special request.

OBSOLETE

Summary of Contents for Gem TY-B

Page 1: ...te level version of the Series TY B Pendent Sprinkler can be obtained by utilizing the Series TY B Pendent Sprinkler in combination with the Model S2 Shield WARNINGS The Series TY B Sprinklers described herein must be installed and main tained in compliance with this docu ment as well as with the applicable standards of the National Fire Protec tion Association in addition to the standards of any ...

Page 2: ... orifice seat on frame Pipe thread connections per ISO 7 1 can be provided on special request 2 4 5 6 PENDENT CROSS SECTION 58 7 mm 2 5 16 39 7 mm 1 9 16 PLATE SEATING ESCUTCHEON 1 2 12 7 mm NOMINAL MAKE IN SURFACE 1 3 NPT 3 4 RECESSED PENDENT UPRIGHT 12 7 mm NOMINAL MAKE IN 1 2 RECESSED STYLE 40 ESCUTCHEON 57 2 mm 2 1 4 3 4 NPT DEFLECTOR SSU SSP DEFLECTOR 7 FLATS WRENCH 2 7 8 73 0 mm DIA FIGURE 2...

Page 3: ...position of the sprinkler fitting to suit The Series TY B Pendent and Up right Sprinklers must be installed in accordance with the following instruc tions Step 1 Pendent sprinklers are to be installed in the pendent position and upright sprinklers are to be installed in the upright position Step 2 With pipe thread sealant ap plied to the pipe threads hand tighten the sprinkler into the sprinkler f...

Page 4: ...orrosion Resistant Sprinklers Installed with Style 10 1 2 NPT or Style 40 3 4 NPT 3 4 Total Adjustment Recessed Escutcheon as applicable 150 F 66 C Maximum Ceiling Temperature White or Any Color Frame and Deflector only N A Not Available TABLE A LABORATORY LISTINGS AND APPROVALS 1 2 5 WAX OVER LEAD COATED LEAD COATED WAX COATED N A 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 1 2 3 5 N A 5 6 1 2 NPT PENDENT TY...

Page 5: ...gled downward and then touch the wax stick to the rod approximately one half inch away from the area re quiring retouching The wax will melt and run down onto the sprinkler The Series TY B Recessed Pendent Sprinklers must be installed in ac cordance with the following instruc tions Step A After installing the Style 10 or 40 Mounting Plate as applicable over the sprinkler threads and with pipe TFP1...

Page 6: ...pec tions should be made so as to better determine the exact sprinkler condi tion and the long term integrity of the corrosion resistant coating as it may be affected by the corrosive conditions present The owner is responsible for the in spection testing and maintenance of their fire protection system and de vices in compliance with this docu ment as well as with the applicable standards of the N...

Page 7: ...ify Specify color color coded Wax Stick for retouching specify tem perature rating temperature rated Se ries TY B Sprinklers P N specify Black for 135 F P N 56 065 1 135 Red for 155 F P N 56 065 1 155 Yellow for 175 F P N 56 065 1 175 Blue for 200 F and 286 F P N 56 065 1 286 NOTES Each wax stick is suitable for retouch ing up to twenty five sprinklers The wax used for 286 F sprinklers is the same...

Page 8: ...Page 8 of 8 TFP151 TYCO FIRE PRODUCTS 451 North Cannon Avenue Lansdale Pennsylvania 19446 O B S O L E T E ...

Reviews: