Instruction Sheet
Hand Crimping Tool
2063811- 1 for STRATO- THERM*
408--10367
LOC B
1
of 5
E
2010 Tyco Electronics Corporation, Berwyn, PA
All Rights Reserved
TE logo and Tyco Electronics are trademarks.
*Trademark. Other product names, logos, or company names might be trademarks of their respective owners.
TOOLING ASSISTANCE CENTER 1--800--722--1111
PRODUCT INFORMATION 1--800--522--6752
This controlled document is subject to change.
For latest revision and Regional Customer Service,
visit our website at
www.tycoelectronics.com
G
Trademark of E.I. Du Pont de Nemours & Co.
11 JUN 10 Rev A
Pre- Insulated Spare Wire Caps
PROPER USE GUIDELINES
Cumulative Trauma Disorders can result from the prolonged use of manually powered hand tools. Hand tools are intended for occasional use and low volume
applications. A wide selection of powered application equipment for extended--use, production operations is available.
Figure 1
Color Coded to Indicate Wire
Insulation Diameter Range of Cap
Unstripped Wire
Color Code of
Crimping Dies
Crimping Die
Color Codes
“A”
Ring
“B”
Ring
Spare
Wire Cap
Orange
Green
White
1. INTRODUCTION
This instruction sheet covers the application,
maintenance, and inspection of Hand Crimping Tool
2063811--1, which is used to apply STRATO--THERM
pre--insulated spare wire caps on unstripped
TEFLON
G
insulated wire having an insulation
diameter range of 0.91 -- 3.50 mm [.036 --.138 in.].
Read this sheet thoroughly before proceeding. Refer
to Catalog 82011 for product part numbers, wire
insulation diameter, and proper color codes.
Dimensions on this sheet are in millimeters [with
inch equivalent dimensions in brackets]. Figures
and illustrations are for identification only and are
not drawn to scale.
Reasons for reissue are provided in Section 7,
REVISION SUMMARY.
2. DESCRIPTION
The tool features three crimping areas, tool handles,
and a CERTI--CRIMP* Hand Crimping Tool Ratchet
Control. Tool dies and spare wire cap rings are color
coded for a given wire insulation diameter range.
Crimp the color coded ring (“B”) in the matching color
coded dies. See Figures 1 and 2. Example: If
insulation diameter of wire is within a range of 1.422
to 1.63 mm [.056 --.064 in.], use ring “A.”
3. CRIMPING PROCEDURE
To apply the wire cap, proceed as follows:
1. Open crimping dies by closing handles until
CERTI--CRIMP ratchet releases. Note that, once
ratchet is engaged, handles cannot be opened until
they are first fully closed.
2. Place cap in matching color coded dies (ring “B”
on cap must match die color code). Be sure cap is
fully bottomed in tool and rings are centered in
crimping dies. See Figure 3.
Figure 2
Cap Bottomed
and Rings
Centered in
Dies
Ring “B”
Matches
Color
Code of
Dies
Unstripped
Wire
3. Close handles until cap is firmly in place. Do
NOT deform cap.
4. Insert UNSTRIPPED wire all the way into cap.
5. To complete crimp, close handles until
CERTI--CRIMP ratchet releases. Open the handles
and remove the crimped cap.
6. Refer to Section 4 and Figure 3 for spare wire
cap crimp inspection procedure.
7. “REJECT” spare wire caps can be avoided
through careful use of instructions in Section 2
,
and by performing regular tool maintenance as
instructed in Section 5.
4. CRIMP INSPECTION
1. Inspect crimped spare wire caps by checking
the features described in Figure 3.
NOTE
i