Page 14 / 14 ECOC: EGC0 ; LOC: AI
P/N 1-1579002-2
411-18506 Rev B
7 Maintenance, Inspection
7.1 Daily Maintenance
Following steps are recommended for daily maintenance of the hand tool:
1. Remove dust, moisture and any other contaminants from the tool with a clean, soft brush or a clean,
soft lint-free cloth. Do not use hard or abrasive objects that could damage the tool.
2. Make certain that the pivot pins are in place and secured with the retaining rings. The screwed stop
pin of the adjustment wheels must be tight.
3. When the tool is not in use, store it in a clean, dry area.
7.2 Periodic inspection
Inspections of the tool should be recorded frequently.
1. Remove any debris which could affect the function of the hand tool.
2. Make certain that all pivot pins are in place and secured with retaining plates.
3. Close tool handles completely and then allow them to open freely. If they do not open quickly and fully,
the spring is defective and must be replaced.
4. Protect the joints from soiling and apply light machine oil to them regulary.
8 Spare and wear parts
The spare parts of stripping hand tool are listed in the following table.
Instruction sheet 411-18506 / TE P/N 1-744014-6
Tension spring (Pos.2) will be replaced from Tyco Electronics customer service.
Part
Description
TE P/N
Quantity
1
Stripping Blade
3-1579005-7
4
2
Tension spring
2-1579025-0
1