4.5.3.4      DRAM Memory Mapping 
 

 

 
Chipselect Interleaving 

Interleave memory blocks across the DRAM chip selects for node 0. 

Disabled

 / Auto 

 
BankGroupSwap 

This is an advanced performance setting, specifies if the system should use DRAM 
Bank Group swap mode. 

Disabled

 / 

Enabled

 / Auto 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for TN76A-B8242

Page 1: ...1 http www tyan com TN76A B8242 Service Engineer s Manual...

Page 2: ...2 http www tyan com...

Page 3: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Page 4: ...les These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate rad...

Page 5: ...Do not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer D...

Page 6: ...s memory modules hard drivers and other optional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter4...

Page 7: ...the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it...

Page 8: ...before you install operate or service TYAN products Symbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipmen...

Page 9: ...ct in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages might be present Conductive...

Page 10: ...epth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack cannot ha...

Page 11: ...pment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external conta...

Page 12: ...hing internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damag...

Page 13: ...39 2 1 Installing Motherboard Components 40 2 1 1 Removing the Chassis Cover 40 2 1 2 Removing the Riser Card Brackets 41 2 1 3 Installing the CPU Heatsink 43 2 1 4 Installing the Memory 46 2 1 5 Mem...

Page 14: ...rboard Cables 87 3 10 Removing the Motherboard 88 3 11 Replacing the Power Supply 89 Chapter 4 BIOS Setup 90 4 1 About the BIOS 90 4 2 Main Menu 92 4 3 Advanced Menu 94 4 4 Chipset Menu 125 4 5 AMD Co...

Page 15: ...E bus implementation The TN76A B8242 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the TN76A B8242 in a version that...

Page 16: ...Bay Q ty Type 24 2 5 Hot Swap SSD HDD 2 2 5 Hot Swap SSD 7mm HDD Backplane Support SAS 12Gb s SATA 6Gb s Supported HDD Interface 2 SATA 6Gb s 7mm 24 SATA 6Gb s SAS 12Gb s System Cooling Configuration...

Page 17: ...for 1 PCI E Gen3 x16 2 PCI E Gen3 x8 slots right 1 M8242T76 L16 2F riser card for 1 PCI E Gen3 x16 slot 1 PCI E Gen3 x8 slots left 1 M8242T76 R16 2F riser card for 1 PCI E Gen3 x16 1 PCI E Gen3 x8 sl...

Page 18: ...ator Fan PSU fail LED indicator Others Watchdog timer support Server Management Onboard Chipset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over...

Page 19: ...U Rackmount Chassis Model TN76A Dimension D x W x H 30 12 x 17 24 x 3 45 765 x 438 x 87 6mm Motherboard Name S8242GM2N 2V Motherboard Notification The motherboard not sold separately Gross Weight 30 k...

Page 20: ...l 8 Channels per CPU Memory voltage 1 2V Expansion Slots PCI E 1 PCI E Gen3 x8 slot HH HL w x4 link 1 PCI E Gen3 x16 slot FH 10 5 L 4 PCI E Gen3 x8 slots HH HL Pre install TYAN Riser Card PCI E Gen3 1...

Page 21: ...Aspeed AST2500 I O Ports USB 2 USB3 0 ports rear 1 USB3 0 ports at front COM 1 DB 9 port COM1 1 header COM2 VGA 1 D Sub 15 pin port RJ 45 1 GbE port dedicated for IPMI SFP 2 25GbE SFP28 ports Others...

Page 22: ...onsole Redirection ACPI sleeping states S0 S1 S5 FAN speed control automatic ACPI 6 0 Operating System OS supported list Please refer to our AVL support lists Regulation FCC DoC Class A CE DoC Class A...

Page 23: ...Swap SSD HDD 2 2 5 Hot Swap SSD 7mm HDD Backplane Support SAS 12Gb s SATA 6Gb s NVMe Supported HDD Interface 24 2 5 NVMe 2 SATA 6Gb s 7mm System Cooling Configuration Redundancy Yes FAN 11 1 6cm fans...

Page 24: ...ht Pre install TYAN Mezz Card PCI E Gen3 3 M2093 storage mezz cards w 4 PCI E x8 SFF 8611 OCuLink connectors for 12 NVMe ports 1 M2094 storage mezz card w 3 PCI E x8 SFF 8611 OCuLink connectors for 6...

Page 25: ...pset Onboard Aspeed AST2500 AST2500 iKVM Feature 24 bit high quality video compression Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2500 IPMI Feature IPMI 2 0 compliant ba...

Page 26: ...ng Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Package Contains Barebone 1 TN76A B8242 Barebone Manual 1 Quick Installation Guide NOTE 1 The specifications are subject to change wit...

Page 27: ...tinum 1200W RPSU DPS 1200AB 4 B power supply unit 1 S8242GM2N 2V system board pre installed 1 M1715T71 FPB Front Panel Board pre installed 1 M1714T71 USB USB Board pre installed 1 MP016T76 FB Fan Boar...

Page 28: ...te for service http www tyan com The web site also provides information of other TYAN products as well as FAQs compatibility lists BIOS settings etc Accessory Kit 1 Sliding Rail kit 1 Quick Installati...

Page 29: ...http www tyan com 29 1 5 About the Product The following views show you the product 1 5 1 System Front View...

Page 30: ...ehavior Power LED 1 Green System Power On Solid On System Power Off Off Fault LED 1 Orange System Normal Off System Warning Solid On ID LED 1 Blue ID Located Solid On HDD SSD LED Definitions LED Drive...

Page 31: ...System Rear View No Description No Description 1 LP PCIE Gen3 Slot 2 9 SFP 1 interface from mezzanine card 2 FH PCIE Gen3 Slot 3 10 SFP 2 3 FH PCIE Gen3 Slot 3 11 ID LED 4 LP PCIE Gen3 Slot 2 12 ID L...

Page 32: ...nitions Dual color Power Supply Condition Green LED Amber LED No AC power to all power supplies OFF OFF Power supply critical event causing a shutdown failure OCP OVP Fan Fail OTP UVP OFF AMBER Power...

Page 33: ...p www tyan com 33 1 5 3 Board Image S8242 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pict...

Page 34: ...http www tyan com 34 1 5 4 Block Diagram...

Page 35: ...http www tyan com 35 1 5 5 Motherboard Mechanical Drawing...

Page 36: ...http www tyan com 36 1 5 6 System Top View...

Page 37: ...er Card Bracket M2094 Riser Card pre installed 3 Front Panel Bezel M1715T71 FPB pre installed 10 Riser Card Bracket M2093 M8242T76 L16 2F Riser Card pre installed 4 6 System Fan 11 Riser Card Bracket...

Page 38: ...er tools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A he...

Page 39: ...d touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static su...

Page 40: ...ing CPU heatsink air duct memory modules HDD SSD and LAN Card 2 1 1 Removing the Chassis Cover Follow these instructions to remove the TN76A B8242 chassis cover 1 Rotate the screw with a screwdriver c...

Page 41: ...g the Riser Card Brackets Follow these instructions to remove the PCI E Riser Card Brackets 1 There are four PCIE brackets in the TN76A B8242 chassis 2 Unscrew to release the PCI E Riser Card Brackets...

Page 42: ...http www tyan com 42 4 Disconnect the Oculink cables 5 Disconnect the Oculink cables...

Page 43: ...the screws securing the force frame in a sequential order 3 2 1 Note The force frame will automatically eject after the captive screws are being released 2 By placing your both index fingers on the s...

Page 44: ...ame with package into the slot on the rail frame Note During installation observe the following NOTE During installation observe the following 1 Make sure to push the carrier frame with package toward...

Page 45: ...l frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential order 1 2 3 8 To secure the heatsink use...

Page 46: ...ing levers in the direction of the arrows as shown in the following illustration Always start at CPU0_DIMM_A0 2 Align the memory module with the slot When inserted properly the memory slot locking lev...

Page 47: ...http www tyan com 47 2 1 5 Memory Memory population table...

Page 48: ...NV NV NVDIMMs are identical per channel pair NV NV NV NV Populating NVDIMMs with RDIMMs or LRDIMMs D NV D R LR or 3DS DIMM type Da Da NV Da Da Db NV Db capacity 2x Da capacity NV D NV Da NV Da NV Tab...

Page 49: ...P0_D1_UMC1_CH_B0 P0_D1_UMC1_CH_B1 P0_D0_UMC1_CH_C0 P0_D0_UMC1_CH_C1 P0_D0_UMC0_CH_D0 P0_D0_UMC0_CH_D1 P0_D3_UMC0_CH_E0 P0_D3_UMC0_CH_E1 P0_D3_UMC1_CH_F0 P0_D3_UMC1_CH_F1 P0_D2_UMC1_CH_G0 P0_D2_UMC1_C...

Page 50: ...http www tyan com 50 P1_D3_UMC0_CH_E0 P1_D3_UMC0_CH_E1 P1_D3_UMC1_CH_F0 P1_D3_UMC1_CH_F1 P1_D2_UMC1_CH_G0 P1_D2_UMC1_CH_G1 P1_D2_UMC0_CH_H0 P1_D2_UMC0_CH_H1...

Page 51: ...tructions to install hot swap 2 5 7 9mm SATA 6G hard drives and hot swap 2 5 SATA 6Gb s SSD HDD Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 2 5 7...

Page 52: ...http www tyan com 52 2 To pull the hard disk tray out 3 Option 1 2 5 SSD Place a 2 5 hard drive into the SSD tray and stuck the SSD into the SSD tray 4 Reinsert the HDD tray into the chassis...

Page 53: ...http www tyan com 53 2 5 SATA 6Gb s SSD HDD 1 Press down the latch to unlock the HDD trays 2 To pull the hard disk tray out...

Page 54: ...http www tyan com 54 3 Remove the 4 screws to detach HDD tray bracket 4 Place a hard drive into the drive tray Use four screws to secure the HDD 5 Reinsert the HDD tray into the chassis...

Page 55: ...http www tyan com 55 6 Press the locking lever to lock the 2 5 SSD HDD tray...

Page 56: ...ended that at least two people lift the TYAN TN76A B8242 to and from the rack Rack mounting kit No Item Description Quantity A Sliding rails 2 B Screw packet in rail kit 1 2 2 1 Installing the Server...

Page 57: ...inner rails to the chassis 1 Press the locking tab to draw out the inner rail from the rail assembly 2 Take out the rails and identify to pull the rail to the full length 3 Install the inner rail to t...

Page 58: ...e been installed and that the unit has been fully tested However to make the installation easier we suggest that you remove all HDD trays before you insert the chassis to the rack 1 Screw the outer ra...

Page 59: ...http www tyan com 59 3 Slide the chassis back into the rack 4 Screw the chassis to the rack using 2pcs rotate screw 5 The installation is now complete...

Page 60: ...herboard M1244T70A BP12 8 B8026 M1285T70A BPE 8 M1293T76A BP6 2 HDD Backplane Board M8242T76 L16 2F M8242T76 R16 2F M7106 R24 3F M7106 L24 3F riser card M2094 M2093 NVMe riser card M1715T71 FPB Front...

Page 61: ...http www tyan com 61...

Page 62: ...replace motherboard components including the motherboard 3 3 Replacing PCI E Riser Cards The TN76A B8242 has four pre installed PCI E riser cards Follow the instructions below to disassemble theM8242...

Page 63: ...http www tyan com 63 3 Unscrew the M2094 riser card to replace with a new one...

Page 64: ...R24 3F Riser Card M7106 L24 3F Riser Card Specifications Support 2 PCI E Gen 3 Slots PCIe x16 Slot x1 PCIe x8 Slot x2 1 S4P Power Connector M7106 R24 3F Riser Card Specifications Support 3 PCI E Gen 3...

Page 65: ...OcuLink Card M2093 PCI E OcuLink Card Specifications PCI E x16 Gen3 slot interface 2 PCI E x8 OcuLink connector M2094 PCI E OcuLink Card M2094 PCI E OcuLink Card Specifications PCI E x24 Gen3 slot int...

Page 66: ...the M8242T76 L16 2F M8242T76 R16 2F riser card 4 Follow the same procedure to remove the M2093 NVMe riser card 5 Unscrew the M8242T76 L16 2F riser card to replace a new one if necessary 6 Unscrew to...

Page 67: ...http www tyan com 67 7 Unscrew the M8242T76 L16 2F riser card to replace with a new one...

Page 68: ...http www tyan com 68 3 3 2 PCIE Riser card Features M8242T76 L16 2F riser card M8242T76 R16 2F riser card...

Page 69: ...ww tyan com 69 3 4 Replacing the Fans Follow these instructions to replace the fans 1 Take out the fan module from the chassis 2 Replace the failed fan module with a new one 3 Loose the screws on both...

Page 70: ...an com 70 4 Push the latch in the direction as the arrow shown to release the fan from the iron holder 5 Remove the iron holder to replace a new fan Follow the procedure reverse order to reinstall the...

Page 71: ...http www tyan com 71 3 5 Replacing the Fan Board Follow these instructions to replace the MP016T76 FB Fan Board 1 Take out all the system fans 2 Remove the six screws 3 Lift the fan chassis up...

Page 72: ...http www tyan com 72 4 Disconnect the fan cable and fan power cable 5 Take out the fan module and remove the 8 screws...

Page 73: ...in details Front view Rear view Form Factor W389 5 x L54 mm 4 layer PCB Specifications 12 FAN Connector 2 Power Connector J2 J5 2 FAN Cable Connector J1 J6 LEDs 12 Fan Fail LEDs 3 5 2 Fan Board LED D...

Page 74: ...CH 5 6 SYS_FAN8_TACH SYS_FAN4_TACH 7 8 SYS_FAN9_TACH SYS_FAN5_TACH 9 10 SYS_FAN10_TACH GND 11 12 GND PWM_SYS2 13 14 PWM_SYS1 SYS_FAN11_TACH 15 16 NA SYS_FAN12_TACH 17 18 NA VCC3_AUX 19 20 PWM_SYS3 VCC...

Page 75: ...the HDD Backplane Board Follow these instructions to replace the M1244T70A BP12 8 B8026 and M1293T76A BP6 2 HDD Backplane Boards M1244T70A BP12 8 B8026 1 Pull all front HDD trays out 2 Disconnect the...

Page 76: ...www tyan com 76 3 Loose the screws on the top side of the chassis 4 Loose the screws on both sides of the chassis 5 Loose screws on the chassis and take out the HDDs chassis to push the HDD backplane...

Page 77: ...here are three M1244T70A BP12 8 B8026 backplane Boards installing on the chassis Loose 6 screws to lift the mylar 8 Reinstall the HDD BP Board into the chassis following the steps in reverse M1293T76A...

Page 78: ...HDD Backplane Features Front View Rear View M1244T70A BP6 8 B8026 HDD Backplane Board Form Factor 8 layer PCB Integrated I O 1 8 pin Power Connector PW3 2 Mini SAS Connector 8 HDD Connector 2 5 SAS SA...

Page 79: ...view Rear view M1285T70A BPE 8 HDD Backplane Board Form Factor 6 layer PCB 76 8mm x 134 4mm Specifications 8 2 5 hot swap NVMe SSDs support 4 OcuLink connector 1 2x4 pin power connector 1 SGPIO conne...

Page 80: ...293T76A BP6 2 HDD Backplane Board Form Factor 4 layers PCB Integrated I O 2 SATA Connector 0 1 2 HDD Connector 0 1 M1244T70A BP6 8 B8026 HDD Backplane Board PW3 8 pin Power Connector Definition Pin Pi...

Page 81: ...yan com 3 7 Replacing the Front Panel Board Follow these instructions to replace the M1715T71 FPB Front Panel Board 1 Unscrew the front panel bezel 2 Take out the front panel bezel 3 Unscrew the Front...

Page 82: ...http www tyan com 82 4 Disconnect the Front Panel control cable 4 Reinstall the Front Panel Board into the chassis following the steps in reverse...

Page 83: ...ows the M1715T71 FPB Front Panel Board in details Form Factor W37xL19xT1 6mm 2 layer PCB Specifications 1 Front Panel Board Connector J1 1 Power Button with green color Power LED J3 1 ID Button SW1 1...

Page 84: ...red in the system Off Off System works fine Power LED On Green System powered on Blinking Green System standing by Off Off System AC off J1 Front Panel Board Connector Definition Pin Pin Definition FP...

Page 85: ...om 85 3 8 Replacing the USB Board Follow these instructions to replace the M1714T71 USB USB Board 1 Unscrew 4 screws to release the USB board bezel 2 Take out the USB Board bezel 3 Disconnect the Fron...

Page 86: ...http www tyan com 86 4 Unscrew the USB Board to replace with a new one 5 Reinstall the USB Board bracket into the chassis following the steps in reverse order...

Page 87: ...om 87 3 9 Disconnecting All Motherboard Cables Before replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all cables 1 Discon...

Page 88: ...erboard After removing all of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the nine screws securing the motherboard to the chassis 2 Care...

Page 89: ...installed Power Supply Units Please unplug the power cord before you follow these instructions to replace the power supply units 1 Press the latch to pull the power supply out 2 After replacing a new...

Page 90: ...ion describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are then stored in a dedicated battery backed memory called NVRAM that retains the info...

Page 91: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 4 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Page 92: ...hanged within the Main Setup screen BIOS Information It displays BIOS related information Platform Information It displays Platform information Memory Information This displays the total memory size S...

Page 93: ...http www tyan com 93 System Time Set the Time Use Tab to switch between Time elements...

Page 94: ...U Configuration CPU Configuration parameters Onboard Device Configuration Onboard Device and Function Configuration PCIE Slot Configuration Onboard PCIE Slot Configuraion Trusted Computing Trusted Com...

Page 95: ...PCI Subsystem Settings PCI PCI X and PCI Express Settings USB Configuration USB Configuration Parameters CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc NVMe Confi...

Page 96: ...ation submenu SVM Mode Enable disable CPU Virtualization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related to CPU 0 CPU 1 Inform...

Page 97: ...http www tyan com 97 4 3 1 1 CPU0 Information...

Page 98: ...http www tyan com 98 4 3 1 2 CPU1 Information Read only...

Page 99: ...led Disabled Active Video Select between onboard or external VGA support Onboard Offboard Onboard LAN Mellanox Enable Disable Onboard LAN Devices Disabled Enabled NMI Button Enable or Disable NMI butt...

Page 100: ...on PCIE Slot Configuration SATA or NVMe link Select J1 J2 Select link header function as NVMe or SATA function NVMe SATA SATA or NVMe link Select J3 J4 Select link header function as NVMe or SATA func...

Page 101: ...etting PCIe Slot Link Width Auto is detected by GPIO x8x8 x16 X4x4x4x4 x8 x16 Riser2 Down Slot Link Width Configuration Setting PCIe Slot Link Width x4x4 x4 Riser 3 Middle Slot Link Width Configuratio...

Page 102: ...ration OCP Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen 1 2 5 GT s Gen2 5 GT s Gen3 8 GT s Riser 1 Up Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen 1 2 5 G...

Page 103: ...wn Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen 1 2 5 GT s Gen 2 5 GT s Gen 3 8 GT s 4 3 4 Trusted Computing Security Device Support Enable or disable BIOS support for security...

Page 104: ...Manual Full Speed NOTE When Auto Fan Control was set to Manual PWM Minimal Duty Cycle And BMC Alert Beep Item will appear PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BMC Alert Beep Enable Disabl...

Page 105: ...105 4 3 5 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Page 106: ...http www tyan com 106...

Page 107: ...d Select dynamic time system will wake on the current time increase minute s Disabled Fixed time Dynamic time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3...

Page 108: ...puter which the user is using will exchange data Both computers should have the same or compatible settings NOTE Console Redirection Settings menu only appear when Console Redirection was set to Enabl...

Page 109: ...l port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the...

Page 110: ...rt signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key Support Enable VT UTF8 Combination Key Support for ANSI...

Page 111: ...l port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 115200 57600 Data Bits 8 7 Parity A parity bit can be sent with the...

Page 112: ...t to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 113: ...OM2 Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When Bootloader is selected then Legacy Console Redirection is disabled before booting...

Page 114: ...r OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Page 115: ...the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send st...

Page 116: ...o Disabled the following menu will disappear Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Setti...

Page 117: ...o Disabled the following menu will disappear Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Setti...

Page 118: ...as SR IOV capable PCIe devices this option Enables or Disables Single Root IO virtualization Support Enabled Disabled ARI Forwarding If supported by hardware and set to Enabled the Downstream Port dis...

Page 119: ...w System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes Maximum Read Request Set Maximum Read Request Size of PCI Express Device or allow system BIOS to select the value Auto 128 Bytes 25...

Page 120: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Page 121: ...10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub po...

Page 122: ...Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Other PCI devices Determines O...

Page 123: ...http www tyan com 123 4 3 13 SATA Configuration...

Page 124: ...124 4 3 14 NVDIMM Force Self Refresh Configuration Asset NVDIMM Save on Reset Asset NVDIMM Save on cold reset and warm reset Enabled Disabled Asset NVDIMM Save on Shutdown Asset NVDIMM Save on Shutdow...

Page 125: ...p www tyan com 125 4 4 Chipset Menu SMT Mode Simultaneous multithreading OFF 1T single thread Auto 2T two thread if capable Off Auto Numa Enable or Disable Non uniform Memory Access NUMA Enabled Disab...

Page 126: ...http www tyan com 126 4 4 1 North Bridge Configuration Socket 0 Information View Information related to socket 0 Socket 1 Information View Information related to Socket 1...

Page 127: ...http www tyan com 127 4 4 1 1 Socket 0 Information...

Page 128: ...http www tyan com 128 4 4 1 2 Socket 1 Information...

Page 129: ...anagement Platform First Error Handling Enable disable PFEH cloak individual banks and mask deferred error interrupts from each bank Enabled Disabled MCA Error Threshold Count MCA Error Threshold Coun...

Page 130: ...http www tyan com 130 4 5 AMD Configuration...

Page 131: ...ate Control Controls IO based C state generation and DF C states Disabled Enabled Auto SEV ES ASIO Space Limit SEV VMs using ASIDs below the SEV ES ASIO Space Limit must enable the SEV ES feature The...

Page 132: ...http www tyan com 132 4 5 1 1 Core Thread Enablement...

Page 133: ...ubmenu Downcore control Sets the number of cores to be used Once this option has been used to remove any cores a POWER CYCLE is required in order for future selections to take effect TWD 1 1 TWD 2 0 T...

Page 134: ...134 4 5 1 2 Prefetcher settings L1 Stream HW Prefetcher Option to Enable Disable L1 Stream HW Prefetcher Disable Enable Auto L2 Stream HW Prefetcher Option to Enable Disable L1 Stream HW Prefetcher Di...

Page 135: ...erleaving Controls fabric level memory interleaving AUTO none channel die socket Note that channel die and socket has requirements on memory populations and it will be ignored if the memory doesn t su...

Page 136: ...http www tyan com 136 4 5 3 UMC Common Options...

Page 137: ...http www tyan com 137 4 5 3 1 DDR4 Common Options...

Page 138: ...http www tyan com 138 4 5 3 1 1 DRAM Timing Configuration...

Page 139: ...http www tyan com 139 4 5 3 1 1 1 I Accept Configuration Overclock Memory Overclock settings Auto Enabled...

Page 140: ...http www tyan com 140 4 5 3 2 Common RAS Data Poisoning Enable disable data poisning UMC_CH EccCtrl UcFatalEn UMC_CH EccCtrl WrEccEn should be enabled disabled together Disabled Enabled Auto...

Page 141: ...1 ECC Configuration DRAM ECC Symbol Size DRAM ECC Symbol size x4 x8 UMC_CH EccCtrl EccSymbolSize Disabled Enabled Auto DRAM ECC Enable Use this option to enable disable DRAM ECC Auto will set ECC to...

Page 142: ...http www tyan com 142 4 5 3 3 Security Data Scramble Data scrambling DataScrambleEn Disabled Enabled Auto...

Page 143: ...ping Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0 Disabled Auto BankGroupSwap This is an advanced performance setting specifies if the system should use DRA...

Page 144: ...BIO RAS Control NBIO RAS Control Disabled Enabled Auto Determinism Slider Auto Use default performance determinism settings Power Performance Auto Power Performance cTDP Control Auto Use the fused cTD...

Page 145: ...http www tyan com 145 4 5 4 1 NB Configuration IOMMU Enable Disable IOMMU Disabled Enabled Auto...

Page 146: ...http www tyan com 146 4 5 5 FCH Common Options...

Page 147: ...http www tyan com 147 4 5 5 1 AC Power Loss Options Restore Ac Power Loss Select Ac Loss Control Method Power Off Power On Last State...

Page 148: ...mer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing R...

Page 149: ...sabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled...

Page 150: ...t Disabled Enabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Log EFI Stat...

Page 151: ...http www tyan com 151 4 6 2 BMC Network Configuration...

Page 152: ...e Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp IPV6 Support Enable or Disable LAN1 IPV6 Support Enabled Disabled Configuration Address Source Select the configure LAN channel parameters statica...

Page 153: ...key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm Ne...

Page 154: ...en Platform Key PK is enrolled system mode if 1 system running in User mode with enrolled platform Key PK 2 CSM function is disabled Disabled Enabled Secure Boot Mode Secure Boot mode selector Standar...

Page 155: ...ion Factory Defaults is set to Enabled Install Factory Default Keys Force System to User Mode install all Factory Default Keys Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256...

Page 156: ...ST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Save to File Set New Eras...

Page 157: ...Defaults or load certificates from a file 1 Public Key Certificate in a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3...

Page 158: ...om 158 a EFI_signature_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Autheticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test...

Page 159: ...disable Quiet Boot option Disabled Enabled Endless Boot Enable or disable Endless Boot Disabled Enabled Wait For ESC If Error Enable or disable wait ESC key Function When chassis intrusion CMOS clear...

Page 160: ...160 Boot Option 2 Select the first boot device Device Name Device Name Disabled 4 8 1 Delete Boot Option Configuration Delete Boot Option Remove an EFI boot option from the boot order Select one to D...

Page 161: ...yan com 161 4 8 2 Network Device BBS Priorities Configuration Boot Option 1 Sets the system boot order Device Name Device Name Disabled Boot Option 2 Sets the system boot order Device Name Device Name...

Page 162: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Page 163: ...http www tyan com 163 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options...

Page 164: ...http www tyan com 164 NOTE...

Page 165: ...5 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 166: ...errors 0x60 0x8F DXE execution up to BDS 0x90 0xCF BDS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standa...

Page 167: ...idge initialization after microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization SEC Phase None PEI Phase SEC Error Codes 0x0C 0x0D Reserved for future AMI SEC err...

Page 168: ...zation is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initial...

Page 169: ...dule specific 0x3D Post Memory South Bridge initialization South Bridge module specific 0x3E Post Memory South Bridge initialization South Bridge module specific 0x3F 0x4E OEM post memory initializati...

Page 170: ...EA S3 Resume Boot Script error 0xEB S3 OS wake error 0xEC 0xEF Reserved for future AMI error codes Recovery Progress Codes 0xF0 Recovery condition triggered by firmware Auto recovery 0xF1 Recovery con...

Page 171: ...cific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU module specific 0x68 PCI host bridge initialization 0x69 North Bri...

Page 172: ...7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is starte...

Page 173: ...irtual Address MAP End 0xB2 Legacy Option ROM initialization 0xB3 System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF...

Page 174: ...l is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 Sy...

Page 175: ...http www tyan com 175 NOTE...

Page 176: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Page 177: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Page 178: ...Ctrl Cable M1715T71 FPB board to S8242 M1715T71 FPB Connect to S8242 M B J1 FPIO 2 3 USB Cable USB cable to S8242 USB cable Connect to S8242 M B USB cable USB3 FPIO1 4 Slim 2 5 HDD BP PWR SATA Cable...

Page 179: ...HDD BP1 PW1 HDD BP PWR cable MB PE_PW1 HDD BP1 SGPIO1 SGPIO cable MB J61 HDD BP2 J1 Oculink cable M2093 J2 M8242 L16 2F HDD BP2 J2 Oculink cable M2093 J1 M8242 L16 2F HDD BP2 J3 Oculink cable MB Mini...

Page 180: ...SAS HD SGPIO Cable B8242T76AV18E8HR 2V M1285T70A or M1244T70A to S8242 M B or M2094 M1285 M1244 Connect to S8242 M2094 M1285 HDD BP1 J1 Oculink cable MB Mini SAS HD J1 J2 M1285 HDD BP1 J2 Oculink cabl...

Page 181: ...2T76 L16 2F 5411T5870003 M8242T76 L16 2F Riser Card M2094 5411T5870005 PCI E to 6ports NVMe Riser Card B8242T76AV2E24HR 2V B8242T76AV18E8HR 2V SKU M7106 L24 3F 5411T5640006 M7106 L24 3F Riser Card M20...

Page 182: ...22T57200008 422T57200005 Oculink to Oculink Cable Reversed Signal 750mm B8242T76AV2E24HR 2V SKU FRU CS 0801 FRU CS 0690 422T57200007 422T57200001 Oculink to Oculink Cable 750mm B8242T76AV2E24HR 2V SKU...

Page 183: ...p Sensors This section aims to help readers identify the locations of some specific FAN and Temp Sensors on the motherboard A table of BIOS Temp sensor name explanation is also included for readers re...

Page 184: ...PU1_FAN They detect the fan speed rpm 2 Temp Sensor SYS_Air_Outlet U13 P0_SOC_MOSFET RT3 and P1_SOC_MOSFET RT2 They detect the system temperature around NOTE The CPU PECI is measured in a scale define...

Page 185: ...http www tyan com 185...

Page 186: ...slot P0_D3_ UMC1_CH_F The highest temperature of CPU0 D3 channel F slot P0_D2_ UMC1_CH_G The highest temperature of CPU0 D2 channel G slot P0_D2_ UMC0_CH_H The highest temperature of CPU0 D2 channel...

Page 187: ...to install the IO Plate for OCP Card Here shows how to install the IO Plate for the dual port LAN card M7106 X557 2T2E 1 Unscrew the riser card bracket 2 Remove the riser card bracket from the chassis...

Page 188: ...http www tyan com 188 4 Insert the LAN card into the OCP slot 5 Secure the LAN card to the chassis...

Page 189: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Page 190: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Reviews: