background image

 

http://www.tyan.com 

Memory voltage 

1.2V 

 

Expansion 
Slots 

 

PCI-E 

(1) PCI-E Gen4 x 24 slot, (1) PCI-E Gen4 x 24 slot 
(w/x16 link; can be x24 link if OCP mezz. conn.A is 
not used. Please contact with Tyan technical support 
for details.) 

Recommended TYAN Riser 
Card (PCI-E Gen3) 

M7106-L24-3F, PCI-E x16 slot 2U riser card 
(left) 

,

M7106-R24-3F, PCI-E x16 slot 2U riser card 

(right)

 

Recommended TYAN Riser 
Card (PCI-E Gen4) 

M8036-L24-3F, PCI-E x16 slot 2U riser card (left), 
M8036-R24-3F, PCI-E x16 slot 2U riser card (right) 

Others: 

(1) PCI-E Gen3 x16 OCP 2.0 slot (conn.A+conn.B) or 
(1) PCI-E Gen3 x8 OCP 2.0 slot (conn.A) 

 

LAN 

 

Q'ty / Port 

(2) GbE ports + (1) dedicated for IPMI 

Controller 

Broadcom BCM5720 

PHY 

Realtek RTL8211E 

 

Storage 

 

SATA 

Connector 

(2) SFF-8654 for (16) SATA ports 

Controller 

Direct from AMD CPU 

Speed 

6Gb/s 

RAID 

N/A 

Additional  
SATA 

Connector 

(2) SATA-DOM,(2) SATA 

Controller 

Marvell 9235 

Speed 

6Gb/s 

RAID 

N/A 

NVMe 

Connector (M.2) 

(2) 22110/2280 (by PCI-E Gen3 interface) 

 

Graphic 

 

Connector type 

D-Sub 15-pin 

Resolution 

Up to 1920x1200 

Chipset 

Aspeed AST2500 

 

Input 
/Output 

 

USB 

(2) USB3.0 ports (via cable), (2) USB3.0 ports (at 
rear), (1) Type-A USB3.0 port 

COM 

(1) DB-9 COM Connector (at rear, COM1) +  

(1) Header (COM2) 

VGA 

(1) D-Sub 15-pin VGA port (at rear) 

RJ-45 

(2) GbE ports, (1) Dedicated for IPMI 

Front Panel 

(1) 2x12-pin SSI front panel header 

Power 

SSI 24-pin + 8-pin + 8-pin power connectors 

 

TPM 
(Optional) 

 

TPM Support 

Please refer to our TPM supported list. 

 

System 
Monitoring   

Chipset 

Aspeed AST2500 

Fan 

Total (6) 4-pin headers 

Temperature 

Monitors temperature for CPU & memory & system 

Summary of Contents for S8036

Page 1: ...soft Corporation Winbond is a trademark of Winbond Electronics Corporation Notice Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accur...

Page 2: ...ace Material 35 2 8 Tips on Installing Motherboard in Chassis 36 2 9 Installing the Memory 38 2 10 Attaching Drive Cables 42 2 11 Installing Add In Cards 43 2 12 Connecting External Devices 44 2 13 In...

Page 3: ...oard x 1 SATA Single Cable x 2 Rear IO shielding x 3 1 x S8036 Quick Installation Guide M 2 Screw kit x2 IMPORTANT NOTE Sales samples may not come with any of the accessories listed above If you have...

Page 4: ...There you can find all the information on all TYAN products as well as all the supporting documentation FAQs Drivers and BIOS upgrades 1 2 Hardware Specifications S8036GM2NE Specifications Processor...

Page 5: ...B 2 USB3 0 ports at rear 2 USB 2 0 ports via cable 1 Type A USB3 0 port COM 1 DB 9 COM Connector at rear COM1 1 Header COM2 VGA 1 D Sub 15 pin VGA port at rear RJ 45 2 GbE ports 1 Dedicated for IPMI F...

Page 6: ...5 C 50 F 95 F Non operating Temp 40 C 70 C 40 F 158 F In Non operating Humidity 90 non condensing at 35 C RoHS RoHS 6 6 Compliant Yes Operating System OS supported list Please refer to our AVL support...

Page 7: ...720 PHY Realtek RTL8211E Storage SATA Connector 2 SFF 8654 for 16 SATA ports Controller Direct from AMD CPU Speed 6Gb s RAID N A Additional SATA Connector 2 SATA DOM 2 SATA Controller Marvell 9235 Spe...

Page 8: ...LAN Storage Console Redirection ACPI 6 1 ACPI sleeping states S0 S5 FAN speed control automatic Physical Dimension Form Factor EATX Board Dimension 12 x 13 305 x 330mm Regulation FCC SDoC Class A CE D...

Page 9: ...onditions MiTAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboar...

Page 10: ...http www tyan com 10 2 1 Board Image S8036GM2NE...

Page 11: ...http www tyan com 11 S8036GM2NE LE This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above picture...

Page 12: ...http www tyan com 12 2 2 Block Diagram S8036 Block Diagram...

Page 13: ...http www tyan com 13 2 3 Motherboard Mechanical Drawing...

Page 14: ...ion available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM populatio...

Page 15: ...er HDR_5 13 SATA Connector SATA4 36 CPU SMBUS Header HDR_4 14 SATA Connector SATA3 37 FAN Header FAN_HD1 15 RearFan_2 SYS_FAN_5 38 Front Panel Header FPIO_2 16 RearFan_1 SYS_FAN_4 39 PSMI Header PSMI_...

Page 16: ...LED_M1 iii RESET_LED_LED LED7 viii NGFF2_LED LED_M2 iv P0_PROCHOT_ LED LED4 ix Onboard BMC IPMI ALERT LED IPMI__LED2 v Rear ID LED ID_LED2 x HDD_ACT_LED HDD_LED3 NOTE 1 SD card socket is an OEM reserv...

Page 17: ...SET LAD2 7 8 GND LAD3 9 10 CLK DBG_SERIRQ 11 12 GND DBG_PRES_N 13 14 3VSB NA 15 16 TPM_PP_EN COM2 Serial Port Header Signal Pin Pin Signal DCD 1 2 DSR SIN 3 4 RTS SOUT 5 6 CTS DTR 7 8 RI GND 9 10 KEY...

Page 18: ...ND 2 SATA TX DP 3 SATA TX DN 4 GND 5 SATA RX DN 6 SATA RX DP 7 GND TYPEA_USB1 Vertical Type_A USB3 0 Connector Signal Pin Pin Signal 5V 1 2 USB2 0_DATA_N USB2 0_DATA_P 3 4 GND USB3 0_RX_N 5 6 USB3 0_R...

Page 19: ...r Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH7 TACH3 5 6 TACH8 TACH4 7 8 TACH9 TACH5 9 10 TACH10 GND 11 12 KEY PWM2 13 14 PWM1 TACH11 15 16 SMB_DATA TACH12 17 18 SMB_CLK NC 19 20 PWM3 FPIO2 F...

Page 20: ...Pin Signal VDD_33_RUN 1 2 VDD_33_RUN J1_SATA_NVME 3 4 J2_SATA_NVME GND 5 6 GND 1 3 J1 SlimSAS1 NVME SMBUS 3 5 J1 SlimSAS1 SATA SGPIO J9 J2 NVMe or SATA Select Jumper Signal Pin Pin Signal VDD_33_RUN 1...

Page 21: ...2 3 BMC RESET J194 CMOS Clear Jumper Normal Default Pin 1 2 3 Signal Vbat P0_Vddbt_Rtc_G GND 1 2 Normal RTC Reset DEFAULT 2 3 Clear RTC Registers You can reset the CMOS settings by using this jumper T...

Page 22: ...14 NVME0_TX_P2 A15 NVME0_RX_P2 B15 NVME0_TX_N2 A16 GND B16 GND A17 NVME0_RX_N3 B17 NVME0_TX_P3 A18 NVME0_RX_P3 B18 NVME0_TX_N3 A19 GND B19 GND A20 NVME1_RX_N0 B20 NVME1_TX_P0 A21 NVME1_RX_P0 B21 NVME1...

Page 23: ...D B23 CPU0_PCIE_G1_PESLOT2_TX_N13_C A24 GND B24 CPU0_PCIE_G1_PESLOT2_TX_P13_C A25 CPU0_PCIE_G1_PESLOT2_RX_P13 B25 GND A26 CPU0_PCIE_G1_PESLOT2_RX_N13 B26 GND A27 GND B27 CPU0_PCIE_G1_PESLOT2_TX_N12_C...

Page 24: ..._N3 B69 GND A70 GND B70 CPU0_PCIE_G1_PESLOT2_TX_N2_C A71 GND B71 CPU0_PCIE_G1_PESLOT2_TX_P2_C A72 CPU0_PCIE_G1_PESLOT2_RX_P2 B72 GND A73 CPU0_PCIE_G1_PESLOT2_RX_N2 B73 GND A74 GND B74 CPU0_PCIE_G1_PES...

Page 25: ...2_TX_N16_C A111 GND B111 GND A112 P0_SFP_SMBUS_DATA B112 PE1_SMB2_SCK A113 P0_SFP_SMBUS_CLK B113 PE1_SMB2_SDA A114 GND B114 VDD_12_RUN A115 VDD_12_RUN B115 VDD_12_RUN PESLOT2 Connector pin net pin net...

Page 26: ...1_TX_N7_C A47 CPU0_PCIE_G3_PESLOT1_RX_N7 B47 GND A48 CPU0_PCIE_G3_PESLOT1_RX_P7 B48 NG A49 GND B49 GND A50 NG B50 CPU0_PCIE_G3_PESLOT1_TX_P8_C A51 GND B51 CPU0_PCIE_G3_PESLOT1_TX_N8_C A52 CPU0_PCIE_G3...

Page 27: ...ESLOT2_RX_N18 B94 CPU0_PCIE_G2_PESLOT2_TX_P18_C A95 CPU0_PCIE_G2_PESLOT2_RX_P18 B95 CPU0_PCIE_G2_PESLOT2_TX_N18_C A96 GND B96 GND A97 CPU0_PCIE_G2_PESLOT2_RX_N19 B97 CPU0_PCIE_G2_PESLOT2_TX_P19_C A98...

Page 28: ...n OFF OFF HW Sensor status is normal ON Red HW Sensor status is abnormal LED5 PWR_GOOD_LED Pin Signal VDD_33_DUAL N34667528 State Description OFF OFF System all power is not OK ON Green System all pow...

Page 29: ...on OFF OFF NGFF Active LED off ON Green NGFF Active LED on IPMI_LED2 On board BMC IPMI ALERT LED Pin Signal VDD_33_DUAL BMC_HW_FAULT_N State Description OFF OFF HW Sensor status is normal ON ORG HW Se...

Page 30: ...s below to install the processors and heat sinks Please note that the illustrations are based on socket which may not look exactly like the motherboard you purchased Therefore the illustrations should...

Page 31: ...the rail frame Note During installation observe the following make sure to push the carrier frame with package towards the end of the rail frame until it clicks in place do not drop the carrier frame...

Page 32: ...e rail frame with the installed package Then push both edges of the rail frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure th...

Page 33: ...seconds enter thermal protection and shut down if heatsinks are not installed Caution Take caution of the air flow must be in the direction which paralleled with memories For the safest method of inst...

Page 34: ...http www tyan com 34 3 Connect the heatsink power cable to the mainboard connector...

Page 35: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Page 36: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Page 37: ...ad of metal Although the plastic studs are usable MiTAC recommends using metal studs with screws that will fasten the motherboard more securely in place Below is a chart detailing what the most common...

Page 38: ...he TYAN Web site at http www tyan com for details of the type of memory recommended for your motherboard Support 16 DDR4 288 pin DIMM slots L R DDR4 3200 Mhz w ECC 1 2V RDIMM DDR4 3200 Mhz w ECC Up to...

Page 39: ...6_CH_E1 P0_D3_Umc7_CH_F0 P0_D3_Umc7_CH_F1 P0_D2_Umc5_CH_G0 P0_D2_Umc5_CH_G1 P0_D2_Umc4_CH_H0 P0_D2_Umc4_CH_H1 NOTE 1 indicates a populated DIMM slot 2 Use paired memory installation for max performanc...

Page 40: ...2 DDR4 Frequency MT s DIMM Type 3 DIMM 0 DIMM 1 Rome in legacy platform 4 Rome in optimized platform 4 1 1R 2666 3200 1R 1R 2133 2933 2R or 2DR 2400 3200 1R 2R or 2DR 2133 2933 2R or 2DR 2R or 2DR 21...

Page 41: ...ock a DIMM socket by Press the retaining clip outwardly in the following illustration 2 Align the memory module with the socket such that the DIMM NOTCH match the KEY SLOT on the socket 3 Seat the mod...

Page 42: ...owing illustrates how to make a SATA Cable connection If you are in need of SATA SAS cables or power adapters please contact your local sales representative 1 SATA drive cable connection 2 SATA drive...

Page 43: ...rt the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and th...

Page 44: ...com 5720 chipset Onboard LAN LED Color Definition The Three 3 onboard Ethernet ports have green and Amber LEDs to indicate LAN status The chart below illustrates the different LED states 1Gbps LAN Lin...

Page 45: ...12VA1 GND 2 6 12VA1 GND 3 7 12VA1 GND 4 8 12VA1 2 14 Finishing Up Congratulations on making it this far You have finished setting up the hardware aspect of your computer Before closing up your chassis...

Page 46: ...to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program The setup program lets you modify basic configuration settings The settings are...

Page 47: ...eemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same BIOS setup layout or options While the basic...

Page 48: ...that can directly be changed within the Main Setup screen BIOS Information It displays BIOS related information Product Name It displays Product information BIOS Version It displays BIOS version info...

Page 49: ...Date Set the Date Use Tab to switch between Date elements Default Ranges Year 2005 2099 Months 1 12 Days dependent on month System Time Adjust the system clock HH 24 hours format MM Minutes SS Second...

Page 50: ...CPU Configuration CPU Configuration parameters Onboard Device Configuration Onboard Device and Function Configuration PCIE Slot Configuraion Onboard PCIE Slot Configuration Trusted Computing Trusted C...

Page 51: ...ion PCI Subsystem Settings PCI PCI X and PCI Express Settings USB Configuration USB Configuration Parameters CSM Configuration CSM Configuration Enable Disable Option ROM execution setting etc NVMe Co...

Page 52: ...tyan com 52 3 3 1 CPU Configuration SVM Mode Enable disable CPU virtulization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related...

Page 53: ...http www tyan com 53 3 3 1 1 CPU0 Information...

Page 54: ...d Active Video Select between onboard or external VGA support Onboard Offboard Onboard LAN B5720 Enable Disable Onboard LAN Device Disabled Enabled LAN1 Port1 OPROM Enable Disable Load Option ROM For...

Page 55: ...ctrum Disabled Enabled 3 3 3 PCIE Slot Configuration NVMe SSD Hot Plug Support Enable Disable NVMe SSD Hot Plug Disabled Enabled Combo Link OCUL1 OCUL3 Combo Link OCUL1 OCUL3 Bifurcation OCUL1 SATA OC...

Page 56: ...g OCUL7 OCUL8 OCP Slot Link Width Configuration OCP Slot Link Width Configuration Auto is detected by GPIO x8x8 x16 x8x8 x16 Auto Riser L Up Slot Link Width Configuration Left Riser Up Slot Link Width...

Page 57: ...Down Slot OPROM Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s OCP Slot Link Speed Onboard PCIE Slot Link Speed Configuration Auto Gen1 2 5 GT s Gen2 5 GT s Gen...

Page 58: ...ion Auto Gen1 2 5 GT s Gen2 5 GT s Gen3 8 GT s 3 3 4 Trusted Computing Security Device Support Enable or disable BIOS support for security device O S will not show Security device O S will not show Se...

Page 59: ...an com 59 3 3 5 ACPI Settings Enable ACPI Auto Configuration Enables or Disables BIOS ACPI Auto Configuration Disabled Enabled Lock Legacy Resources Enables or Disables Lock of Legacy Resources Disabl...

Page 60: ...l Auto Fan Control help Full Speed Manual NOTE When Auto Fan Control was set to Manual PWM Minimal Duty Cycle Item will appear PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 BMC Alert Beep Enable Di...

Page 61: ...61 3 3 6 1 Sensor Data Register Monitoring When you enter the Sensor Data Register Monitoring submenu you will see the following dialog window pop out Please wait 8 10 seconds NOTE 1 SDR can not be m...

Page 62: ...http www tyan com 62...

Page 63: ...http www tyan com 63...

Page 64: ...tings Wake system from S5 Enable or disable system wake on alarm event Select Fixed time system will wake on the hr min sec specified Select dynamic time system will wake on the current time increase...

Page 65: ...ial Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the...

Page 66: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 67: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 68: ...rial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 9600 19200 38400 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with t...

Page 69: ...to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 70: ...esolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST when Bootloader is selected then Legacy Console Redirection is disabled before booting to le...

Page 71: ...rver OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Se...

Page 72: ...n sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses tw...

Page 73: ...Active Serial Port 1 View and Set Basis properties of the SIO Logical device Like IO Base IRQ Range DMA Channel and Device Mode Active Serial Port 2 View and Set Basis properties of the SIO Logical d...

Page 74: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5...

Page 75: ...abled Possible Allows the user to change the device resource settings New settings will be reflected on this setup page after system restarts Use Automatic Settings IO 2F8h IRQ 3 DMA IO 3F8h IRQ 3 4 5...

Page 76: ...vices to be decoded in Above 4G Address Space Only if System supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe devices this option Enable or Disable Single...

Page 77: ...oad of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes Maximum Read Request Set Maximum Read Request Size of PCI Express Device or allow System BIOS to s...

Page 78: ...bled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Page 79: ...ce Start Unit command time out 10 sec 20 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for...

Page 80: ...legacy PXE OpROM Do not launch UEFI legacy Storage Controls the execution of UEFI and legacy PXE OpROM Do not launch UEFI legacy Video Controls the execution of UEFI and legacy PXE OpROM Do not launc...

Page 81: ...http www tyan com 81 3 3 13 NVMe Configuration...

Page 82: ...http www tyan com 82 3 3 14 SATA Configuration...

Page 83: ...http www tyan com 83 3 3 15 Network Stack Configuration Network Stack Enable Disable UEFI Network Stack Disable Enable...

Page 84: ...ate the iSCSI function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes and reboot iSCSI Initiator Nam...

Page 85: ...http www tyan com 85 3 4 Chipset Menu North Bridge North Bridge Parameters...

Page 86: ...http www tyan com 86 3 4 1 North Bridge Configuration Memory Configuration Memory Configuration Memory Information Total Memory xxxxx MB Socket 0 Configuration View Information related to Socket 0...

Page 87: ...http www tyan com 87 3 4 1 1 Socket 0 Information...

Page 88: ...http www tyan com 88 3 5 AMD CBS Menu...

Page 89: ...mask deferred error interrupts from each bank Enabled Disabled Auto Core Performance Boost Disable CPB Disabled Auto Global C state Control Controls IO based C state generation and DF C states Disabl...

Page 90: ...http www tyan com 90 3 5 1 1 Performance Submenu...

Page 91: ...OR IN EXCESS OF FACTORY SETTINGS ARE NOT COVERED UNDER YOUR AMD PRODUCT WARRANTY AND MAY NOT BE COVERD BY YOUR SYSTEM Custom Auto Custom Pstate1 Disable disable this Pstate Custom customize this Pstat...

Page 92: ...MAY NOT BE COVERD BY YOUR SYSTEM Custom Auto 3 5 1 1 2 CCD Core Thread Enablement Submenu CCD Control Sets the number of CCDs to be used Once this option has been used to remove any CCDs a POWER CYCLE...

Page 93: ...d after selecting the Auto option WARNING S3 is NOT SUPPORTED on systems where SMT is disabled Disable Auto 3 5 1 2 Prefetcher Submenu L1 Stream HW Prefetcher Option to Enable Disable L1 Stream HW Pre...

Page 94: ...http www tyan com 94 3 5 2 DF Common Options Submenu...

Page 95: ...e honored regardless of this setting Disabled Auto Memory interleaving size Controls the memory interleaving size The valid values are AUTO 256 bytes 512 bytes 1 kbytes or 2kbytes This determines the...

Page 96: ...http www tyan com 96 3 5 3 UMC Common Options Submenu...

Page 97: ...http www tyan com 97 3 5 3 1 DDR4 Common Options Submenu...

Page 98: ...http www tyan com 98 3 5 3 1 1 DRAM Time Configuration Submenu Overclock Memory Overclock Settings Auto Enabled...

Page 99: ...able IOMMU Disable Enable Auto ACS Enable Supported functions of Access Control Services Enable Disabled Auto PCIe ARI Support Enables Alternative Routing IO Interpretation Disable Enable Auto Enable...

Page 100: ...to Use the fused TDP Manual User can set customized TDP TDP is used to define the RC thermal model only Manual Auto EfficiencyModeEn 0 use performance optimized CCLK DPM settings 1 use power efficienc...

Page 101: ...IS mission mode 1 APBDIS 0 1 Auto DF Cstates Enable Enable DF C states Disable Disable DF C states Disabled Enabled Auto BoostFmaxEn Auto Use the default Fmax Manual User can set the boost Fmax Manual...

Page 102: ...http www tyan com 102 3 5 4 1 AC Power LOSS Options Submenu Restore Ac Power Loss Select Ac Loss Control Method Power Off Power On Last State...

Page 103: ...http www tyan com 103 3 5 4 2 FCH RAS Options Submenu Reset after sync flood Enable AB to forward downstream sync flood message to system controller Disabled Enabled Auto...

Page 104: ...mer Expiration value 3 minutes 4 minutes 5 minutes 6 minutes FBR 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Timer is disabled Do Nothing R...

Page 105: ...sabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog Timer is disabled...

Page 106: ...ed Disabled Erase SEL Choose options for erasing SEL No Yes on next reset No on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing Erase Immediately Delete Oldest Recor...

Page 107: ...http www tyan com 107 3 6 2 BMC Network Configuration Submenu...

Page 108: ...cified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 Enable Disable BMC Share NIC Disabled Enabled Configure...

Page 109: ...trator Password Set Administrator Password User Password Set User Password Security Frozen Mode Enable or disable HDD security freeze lock Disable to support secure erase function Disabled Enabled Sec...

Page 110: ...yed and CSM function is disabled Enabled Disabled Secure Boot Mode Secure Boot mode selector Custom mode enables users to change Image execution policy and manage secure boot keys Standard Custom NOTE...

Page 111: ...ault Secure Boot Keys after the platform reset and while the System is in Setup Mode Enabled Disabled Restore Factory Keys Force System to User Mode Install Factory Default Secure Boot key databases R...

Page 112: ...EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Set New Key Exchange Keys Enroll Factory Defaults or load certificates from a f...

Page 113: ...aults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI...

Page 114: ...waiting Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enabled or Disabled Endless boot Disabled Enabled Wa...

Page 115: ...http www tyan com 115 Boot Option Priorities Boot Option 1 Sets the system boot order Device Name Disabled Delete Boot Option Remove an EFI boot option from the boot order...

Page 116: ...http www tyan com 116 3 8 1 Delete Boot Option Configuration Delete Boot Option Remove an EFI boot option from the boot order Device Name Select one to Delete...

Page 117: ...any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Save changes done so far to any of th...

Page 118: ...http www tyan com 118 Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup options Boot Override Device Name...

Page 119: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 120: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Note used P...

Page 121: ...tion North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initializ...

Page 122: ...odule specific 0x3F 0x4E OEM post memory initialization codes 0x4F DXE PIL is started PCI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory init...

Page 123: ...oaded 0xF5 0xF7 Reserved for future AMI progress codes Recovery Error Codes 0xF8 Recovery PPI is not available 0xF9 Recovery capsule is not found 0xFA Invalid recovery capsule 0xFB 0xFF Reserved for f...

Page 124: ...lization is started 0x71 South Bridge DXE SMM initialization is started 0x72 South Bridge devices initialization 0x73 South Bridge DXE initialization South Bridge module specific 0x74 South Bridge DXE...

Page 125: ...s Codes section below 0xAD Ready To Boot event 0xAE Legacy Boot event 0xAF Exit Boot Services event 0xB0 Runtime Set Virtual Address MAP Begin 0xB1 Runtime Set Virtual Address MAP End 0xB2 Legacy Opti...

Page 126: ...Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met ACPI ASL Checkpoints Status Code Description 0x01 System is entering S1...

Page 127: ...anation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan...

Page 128: ...http www tyan com 128 BIOS Temp Sensor Name Explanation...

Page 129: ...MC0_CH_A The highest temperature of CPU0 D1UMC0 channel A slot P0_D1_UMC1_CH_B The highest temperature of CPU0 D1 UMC1 channel B slot P0_D0_UMC1_CH_C The highest temperature of CPU0 D0 UMC1 channel C...

Page 130: ...YS_FAN_3 SYS_FAN_4 Fan speed of SYS_FAN_4 SYS_FAN_5 Fan speed of SYS_FAN_5 SYS_FAN_6 Fan speed of SYS_FAN_6 SYS_FAN_7 Fan speed of SYS_FAN_7 SYS_FAN_8 Fan speed of SYS_FAN_8 SYS_FAN_9 Fan speed of SYS...

Page 131: ...http www tyan com 131 NOTE...

Page 132: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Page 133: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Page 134: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Page 135: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Page 136: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Page 137: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Page 138: ...omprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system compon...

Page 139: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Reviews: