background image

 

http://www.tyan.com 

90 

3.5.1.1   CCD/Core/Thread Enablement  

 

 
 

CCD control 

Sets the number of CCDs to be used. Once this option has been used to remove 
any CCDs, a POWER CYCLE is required in order for future selections to take effect. 

Auto 

/ 2 CCDs / 3 CCDs / 4 CCDs / 6 CCDs 

 

Core control 

Sets the number of cores to be used. Once this option has been used to remove 
any cores, a POWER CYCLE is required in order for future selections to take effect. 

TWO (1+1) / FOUR (2+2) / SIX (3+3) / 

Auto 

 

 

SMT control 

Can be used to disable symmetric multithreading. To re-enable SMT, a POWER 
CYCLE is needed after selecting the ‘Auto’ option.  

Disabled / 

Auto 

 

 
 
 

Summary of Contents for S8030

Page 1: ...ft Windows are trademarks of Microsoft Corporation Nuvoton is a trademark of Nuvoton Technology Corporation Notice Information contained in this document is furnished by MITAC COMPUTING TECHNOLOGY COR...

Page 2: ...http www tyan com 2...

Page 3: ...g Motherboard in Chassis 30 2 8 Installing the Memory 32 2 9 Attaching Drive Cables 35 2 10 Installing Add In Cards 36 2 11 Connecting External Devices 37 2 12 Installing the Power Supply 38 2 13 Fini...

Page 4: ...al Cable 2 x M 2 Snap Clip Kit 1 x Rear I O Shield SlimSAS 8i to 2 U 2 NVMe cable x 2 Optional FRU FRU CS 1230 miniSAS HD to 4 SATA cable x3 Optional FRU FRU CS 1240 1 x S8030 Quick reference guide IM...

Page 5: ...power and flexibility to meet demanding requirements for today s IT environments Remember to visit the TYAN website at http www tyan com There you can find all the information on all TYAN products as...

Page 6: ...b 15 pin VGA port rear RJ 45 2 GbE ports 1 GbE dedicated for IPMI Front Panel 1 2x12 pin SSI front panel header SATA 2 SATA III connectors 12 SATA ports from 3 Mini SAS HD connectors Power ATX 24 pin...

Page 7: ...ATX Board Dimension 12 x 9 9 305 x 250 8mm Operating System OS supported list Please refer to our AVL support lists Regulation FCC SDoC Class A CE DoC Class A Operating Environment Operating Temp 10 C...

Page 8: ...ek RTL8211E Storage SATA Connector 2 SATA 3 SFF 8643 for 12 SATA ports Controller Direct from AMD EPYC CPU Speed 6Gb s RAID N A NVMe Connector M 2 2 22110 2280 by PCI E Gen 3 x4 SATA interface Connect...

Page 9: ...AST2500 IPMI Feature IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor Boot from USB device PXE via LAN Stora...

Page 10: ...der 4 5 J31 No Yes J44 No Yes J42 System Fan Connector Yes Yes Pin definitions modified M 2 PCIe x2 Slot CN1 CN3 Yes Yes Pin definitions modified Mini SAS HD Connector J25 J26 J27 Yes Yes Pin definiti...

Page 11: ...conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherboa...

Page 12: ...tp www tyan com 12 2 1 Board Image S8030 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Page 13: ...http www tyan com 13 2 2 Block Diagram S8030 Block Diagram...

Page 14: ...http www tyan com 14 2 3 Mainboard Mechanical Drawing...

Page 15: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Page 16: ...10 Mini SAS HD Connector J25 26 ID Button 11 Mini SAS HD Connector J26 27 Stacked USB3 1x2 IPMI LAN5 J51 12 Slim SAS 8x Connector CN2 28 COM VGA J50 13 Mini SAS HD Connector J27 29 LAN3 LAN4 J16 14 2x...

Page 17: ...to your motherboard to keep the system stable and reliable J38 Front Panel Pin Header Signal Pin Pin Signal FP_PW_LED_PW 1 2 FP_CONN_PWR NC 3 4 FP_ID_LED_PW FP_PW_LED_GND 5 6 FP_ID_LED_L HDD_LED_PW 7...

Page 18: ...Front USB3 1 Header Signal Pin Pin Signal VDD_5_USB_REAR 1 20 NC P0_USB_0_SS_0RX_ESD_L 2 19 VDD_5_USB_REAR P0_USB_0_SS_0RX_ESD_H 3 18 P0_USB_0_SS_1RX_ESD_L GND 4 17 P0_USB_0_SS_1RX_ESD_H P0_USB_0_SS_...

Page 19: ...A9 B9 NVME 0 2 _SDA GND A10 B10 GND NVME 0 2 _CLK_DP A11 B11 NVME 0 2 _PERST_L NVME 0 2 _CLK_DN A12 B12 NVME 0 2 _PRSNT_L GND A13 B13 GND NVME 0 2 _RX_P2 A14 B14 NVME 0 2 _TX_P2 NVME 0 2 _RX_N2 A15 B...

Page 20: ...3 _TX_P3 NVME 1 3 _RX_N3 A36 B36 NVME 1 3 _TX_N3 GND A37 B37 GND J25 J26 J27 Mini SAS HD Connector Signal Pin Pin Signal GND1 A3 C3 GND7 RXA0_DP B4 D4 TXA0_DP RXA0_DN B5 D5 TXA0_DN GND2 A6 C6 GND8 RX...

Page 21: ...6 SYS_FAN_T8 7 SYS_FAN_T4 8 SYS_FAN_T9 9 SYS_FAN_T5 10 SYS_FAN_T10 11 GND 12 GND 13 BMC_PWM_BUF_FAN3 14 BMC_PWM_BUF_FAN2 15 SYS_FAN_T11 16 FAN_SDA 17 SYS_FAN_T12 18 FAN_SCL 19 VDD_33_DUAL 20 BMC_PWM_...

Page 22: ...N C PETP2 25 26 N C GND 27 28 N C PERN1 29 30 12V_RUN PERP1 31 32 12V_RUN GND 33 34 12V_RUN PETN1 35 36 12V_RUN Pre Charge PETP1 37 38 M2_DEVSLP GND 39 40 I2C_M2_SCL 1 8V PERN0 SATA B 41 42 I2C_M2_SDA...

Page 23: ...ult setting 3 Move the jumper cap to close Pin_2 and Pin_3 for several seconds to Clear CMOS 4 Put jumper cap back to Pin_1 and Pin_2 Default setting 5 Reconnect power connectors to the motherboard an...

Page 24: ...OM Port1 Default Pin 2 3 Closed BMC Console Port5 J43 Bypass BMC Jumper Pin 1 2 Closed Bypass BMC Pin 2 3 Closed FPGA waits for BMC ready Default J101 ID Button Switch Pin 1 2 Closed Press 5 seconds f...

Page 25: ...ing when it is installed within a high density rack or cabinet that is populated with several other similar systems Off Interface shows off Blinking N a BMC LED On BMC initialing or inactive BMC heart...

Page 26: ...essor Installation for AMD Socket SP3 Follow the steps below to install the processors and heat sinks NOTE Please save and replace the CPU protection cap when returning for service 1 Use a T20 Torx sc...

Page 27: ...the rail frame NOTE During installation observe the following Make sure to push the carrier frame with package towards the end of the rail frame until it clicks into place Do not drop the carrier fra...

Page 28: ...ckage Then push both edges of the rail frame firmly until it locks in place 7 Close the force frame Then use a T20 Torx screwdriver to tighten the screws to secure the force frame in a sequential orde...

Page 29: ...ink screws 10 Connect the heatsink power cable to the mainboard connector NOTE Always check with the manufacturer of the heat sink processor to ensure that the thermal interface material is compatible...

Page 30: ...ply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will...

Page 31: ...http www tyan com 31...

Page 32: ...for your motherboard This platform supports 4 4 DDR4 ECC RDIMM RDIMM 3DS LRDIMM LRDIMM 3DS 3200 Up to 512GB RDIMM 1024GB LRDIMM 2048GB LRDIMM 3DS are supported 1 2V DDR4 DIMMs are supported All insta...

Page 33: ...M type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM Memory Population Table Single CPU Populated CPU0 Quantity of Memory Module Populated 1 2 4 8 P0_UMC0_CH_A0 No...

Page 34: ...structions to install memory modules into the S8030 1 Unlock the clips as shown in the illustration 2 Insert the memory module firmly into the socket by gently pressing down until it sits flush with t...

Page 35: ...are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illust...

Page 36: ...add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the add in card TIP It s a good practi...

Page 37: ...equired to complete the installation Onboard LAN LED Color Definition The five 5 onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED...

Page 38: ...GND PWRGD_PS 8 20 NC VDD_5_STBY_PSU 9 21 VDD_5_RUN VDD_12_RUN 10 22 VDD_5_RUN VDD_12_RUN 11 23 VDD_5_RUN VDD_33_RUN 12 24 GND J63 CPU Power Connector CPU CPU FAN Memory ABCD Signal Pin Pin Signal GND...

Page 39: ...roperly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have exper...

Page 40: ...http www tyan com 40 NOTE...

Page 41: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Page 42: ...r best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same B...

Page 43: ...options that can directly be changed within the Main Setup screen System Language Choose the system default language English Simplified Chinese Japanese System Date Set the Date Use Tab to switch bet...

Page 44: ...figuration Press Enter to select T1s Auth Configuration iSCSI Configuration Configure the iSCSI parameters Network Stack Configuration Network Stack Settings ACPI Settings System ACPI Parameters S5 RT...

Page 45: ...Parameters CSM Configuration CSM configuration Enable Disable Option ROM execution settings etc CPU Configuration CPU Configuration Parameters SATA Configuration SATA Device Information NVMe Configur...

Page 46: ...http www tyan com 46 3 3 1 T1s Auth Configuration Server CA Configuration Press Enter to configure Server CA Client Cert Configuration Press Enter to configure Client Cert...

Page 47: ...http www tyan com 47 3 3 1 1 Server CA Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert...

Page 48: ...oll Cert le Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard Changes...

Page 49: ...http www tyan com 49 3 3 1 2 Delete Cert le FE9C6606 8849 44A3 8868 DEA3A0E0324D GUID for CERT Disabled Enabled...

Page 50: ...1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes and reboot Attempt Priority Change the priority using keys...

Page 51: ...Priority Attempt Priority Change the priority using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Host Attempt Redfish Attempt Commit Chan...

Page 52: ...SI Initiator Only IQN format is accepted Enter iqn xxx xxx ranges from 4 to 223 Add an Attempt Add an attempt Delete Attempt Delete one or more attempts Change Attempt Order Change the priority using...

Page 53: ...http www tyan com 53 3 3 2 2 1 Add an Attempt...

Page 54: ...http www tyan com 54 3 3 2 2 2 Delete Attempts Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit...

Page 55: ...http www tyan com 55 3 3 2 2 3 Change Attempt Order Commit Changes and Exit Commit Changes and Exit Discard Changes and Exit Discard Changes and Exit...

Page 56: ...ems are available when Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV4 PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv4...

Page 57: ...nable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of t...

Page 58: ...http www tyan com 58 3 3 4 ACPI Settings Enable ACPI Auto Configuration Enable or disable BIOS ACPI Auto Configuration Disabled Enabled...

Page 59: ...Select Dynamic Time system will wake on the current time increase minute s Disabled Fixed Time Dynamic Time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3...

Page 60: ...es EMS Console Redirection Console redirection enable or disable Disabled Enabled Legacy Console Redirection Settings Legacy Console redirection settings Console Redirection Settings The settings spec...

Page 61: ...serial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with...

Page 62: ...t to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Key...

Page 63: ...Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When BootLoader is selected then Legacy Console Redirection is disabled before booting to...

Page 64: ...rver OS through a serial port COM1 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setting...

Page 65: ...data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires t...

Page 66: ...led Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled USB Mass Storage Driver Support...

Page 67: ...c 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller AUTO uses default value for a Root port it is 100 ms for a Hub port the...

Page 68: ...A Enabled Disabled Active Video Select between onboard or external VGA support Onboard External LAN1 LAN4 LAN Enable Disable control function Enabled Disabled NMI Button Enable or Disable NMI button E...

Page 69: ...http www tyan com 69 3 3 9 AST2500 Super IO Configuration Super IO Chip Read only Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA...

Page 70: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6...

Page 71: ...trol BIOS setting from Manual to Full Speed when installing the Nvidia GeForce Quardro GPU and any VGA card PWM Minimal Duty Cycle PWM Minimal Duty Cycle 30 NOTE This item is available when Fan Speed...

Page 72: ...http www tyan com 72 3 3 10 1 Sensor Data Register Monitoring NOTE SDR can not be modified Read only...

Page 73: ...ed Option ROM Messages Set display mode for Option ROM Force BIOS Keep Current Network Controls the execution of UEFI and Legacy PXE OpROM UEFI Legacy Storage Controls the execution of UEFI and Legacy...

Page 74: ...http www tyan com 74 Other PCI devices Determines OpRom execution policy for devices other than network storage or video UEFI Legacy...

Page 75: ...yan com 75 3 3 12 CPU Configuration SVM Mode Enable disable CPU Virtualization Disabled Enabled SMEE Control secure memory encryption enable Disabled Enabled CPU 0 Information View Information related...

Page 76: ...http www tyan com 76 3 3 12 1 CPU 0 Information Read only...

Page 77: ...http www tyan com 77 3 3 13 SATA Configuration Read only...

Page 78: ...http www tyan com 78 3 3 14 NVMe Configuration Read only...

Page 79: ...m 79 3 3 15 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available...

Page 80: ...r Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Devices this opti...

Page 81: ...tyan com 81 3 3 16 1 PCI Express Settings Maximum Payload Set Maximum Payload of PCI Express Device or allow System BIOS to select the value Auto 128 Bytes 256 Bytes 512 Bytes 1024 Bytes 2048 Bytes 40...

Page 82: ...1 Option ROM Enabled Disabled LAN2 for S8030GM4NE 2T SKU only Enable or Disable LAN2 Option ROM Enabled Disabled LAN3 Enable or Disable LAN3 Option ROM Enabled Disabled LAN4 Enable or Disable LAN4 Opt...

Page 83: ...lot Bifurcation Configuration PCIE 1 PCIE 5 Selects PCIe port Bifurcation for PCIE 1 PCIE 5 slot x16 x8x8 x4x4x4x4 PCIe Slot Link Speed Configuration PCIE 1 PCIE 5 Maximum Link Speed for PCIE 1 PCIE 5...

Page 84: ...http www tyan com 84 3 4 Chipset Menu PCIe Compliance Mode PCIe Link Compliance Mode Disabled Enabled North Bridge North Bridge Parameters...

Page 85: ...http www tyan com 85 3 4 1 North Bridge Configuration Socket 0 Configuration View Information related to Socket 0...

Page 86: ...http www tyan com 86 3 4 1 1 Socket 0 Information Read only...

Page 87: ...an com 87 3 5 AMD CBS CPU Common Options CPU Common Options DF Common Options DF Common Options UMC Common Options UMC Common Options NBIO Common Options NBIO Common Options FCH Common Options FCH Com...

Page 88: ...ngs Prefetcher Settings Platform First Error Handling Enable disable PFEH cloak individual banks and mask deferred error interrupts from each bank Enabled Disabled Auto Core Performance Boost Disable...

Page 89: ...nual SEV ES ASID Space Limit ASIDs from SEV ES ASID Space Limit to SEV ASID Count 1 can only be used with SEV VMs If this field is set to SEV ASID Count 1 all ASIDs are force to be SEV ES ASIDs Hence...

Page 90: ...ctions to take effect Auto 2 CCDs 3 CCDs 4 CCDs 6 CCDs Core control Sets the number of cores to be used Once this option has been used to remove any cores a POWER CYCLE is required in order for future...

Page 91: ...1 3 5 1 2 Prefetcher Settings L1 Stream HW Prefetcher Option to Enable Disable L1 Stream HW Prefetcher Enabled Disabled Auto L2 Stream HW Prefetcher Option to Enable Disable L2 Stream HW Prefetcher En...

Page 92: ...http www tyan com 92 3 5 2 DF Common Options Scrubber Scrubber Memory Addressing Memory Addressing ACPI ACPI...

Page 93: ...1 Scrubber DRAM scrub time Provide a value that is the number of hours to scrub memory Disabled 1 hour 4 hours 8 hours 16 hours 24 hours 48 hours Auto Redirect scrubber control Redirect scrubber cont...

Page 94: ...S2 NPS4 Memory interleaving Allows for disabling memory interleaving Note that NUMA nodes per socket will be honored regardless of this setting Disabled Auto Memory interleaving size Controls the memo...

Page 95: ...om 95 3 5 2 3 ACPI ACPI SRAT L3 Cache As NUMA Domain Enabled Each CCX in the system will be declared as a separate NUMA domain Disabled Memory Addressing NUMA nodes per socket will be declared Disable...

Page 96: ...http www tyan com 96 3 5 3 UMC Common Options DDR4 Common Options DDR4 Common Options DRAM Memory Mapping DRAM Memory Mapping NVDIMM NVDIMM...

Page 97: ...http www tyan com 97 3 5 3 1 DDR4 Common Options DRAM Timing Configuration DRAM Timing Configuration Common RAS Common RAS Security Security...

Page 98: ...RAM Timing Configuration Overclock Memory Overclock Settings Enabled Auto NOTE The following item is available when Overclock is set to Enabled Memory Clock Speed Specifies the memory clock frequency...

Page 99: ...http www tyan com 99 3 5 3 1 2 Common RAS Data Poisoning Enable disable data poisoning Enabled Disabled Auto ECC Configuration ECC Configuration...

Page 100: ...com 100 3 5 3 1 2 1 ECC Configuration DRAM ECC Symbol Size DRAM ECC Symbol Size x4 x8 x16 x4 x8 x16 Auto DRAM ECC Enable Use this option to enable disable DRAM ECC Auto will set ECC to enable Enabled...

Page 101: ...http www tyan com 101 3 5 3 1 3 Security TSME Transparent Secure Memory Encryption Enabled Disabled Auto Data Scramble Data scrambling Enabled Disabled Auto...

Page 102: ...w tyan com 102 3 5 3 2 DRAM Memory Mapping Chipselect Interleaving Interleave memory blocks across the DRAM chip selects for node 0 Disabled Auto BankGroupSwap Bank Group Swap settings Enabled Disable...

Page 103: ...http www tyan com 103 3 5 3 3 NVDIMM NVDIMM N Feature Disable NVDIMM N feature for memory margin tool Disabled Enabled...

Page 104: ...R must be enabled for ACS enable to work Enabled Disabled Auto PCIe ARI Support Enables Alternative Routing ID Interpretation Enabled Disabled Auto Preferred IO Preferred IO Select Type Manual Bus Num...

Page 105: ...http www tyan com 105 Preferred IO Bus Preferred IO Bus Number 0x0 0xFF Bus Number 0 SMU Common Options SMU Common Options...

Page 106: ...Manual Auto NOTE Determinism Slider is available when Determinism Control is set to Manual Determinism Slider Auto Use default performance determinism settings Power Performance Auto Power Performanc...

Page 107: ...o NOTE Package Power Limit is available when Package Power Limit Control is set to Manual Package Power Limit Package Power Limit PPT W 0 APBDIS 0 not APBDIS mission mode 1 APBDIS 0 1 Auto DF Cstates...

Page 108: ...http www tyan com 108 3 5 5 FCH Common Options AC Power Loss Options AC Power Loss Options...

Page 109: ...http www tyan com 109 3 5 4 1 AC Power Loss Options Restore AC Power Loss Select Restore AC Power Loss Method Power Off Power On Last State...

Page 110: ...value Not available if FRB 2 Timer is disabled 3 minutes 4 minutes 5 minutes 6 minutes FRB 2 Timer Policy Configure how the system should respond if the FRB 2 Timer expires Not available if FRB 2 Tim...

Page 111: ...inutes 20 minutes OS Wtd Timer Policy Configure how the system should respond if the OS Boot Watchdog Timer expires Not available if OS Boot Watchdog timer is disabled Do Nothing Reset Power Down Powe...

Page 112: ...to Disabled the following items are read only Erase SEL Choose options for erasing SEL No Yes on next reset Yes on every reset When SEL is Full Choose options for reactions to a full SEL Do Nothing E...

Page 113: ...ly or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 Enable Disable BM...

Page 114: ...gure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp Management Port 2...

Page 115: ...http www tyan com 115 3 6 3 BMC User Settings Add User Press Enter to Add a user Delete User Press Enter to Delete a user Change User Settings Press Enter to change User Settings...

Page 116: ...ew Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Channel Number 1 Dedicated LAN 8 Shared LAN N A 1 8 User Pri...

Page 117: ...http www tyan com 117 3 6 3 2 Delete User User Name Enter BMC User Name Change User Password Enter New Password to change Password at least 8 characters...

Page 118: ...nter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Channel Number 1 Dedicated LAN 8 Shared LAN N A 1 8 Us...

Page 119: ...ord window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for...

Page 120: ...Custom mode Secure Boot Variables can be configured without authentication Standard Custom Restore Factory Keys Force System to User Mode Install factory default Secure Boot key databases Press Yes t...

Page 121: ...ry Keys Force System to User Mode Install factory default Secure Boot key databases Press Yes to proceed No to cancel Reset to Setup Mode Delete all Secure Boot key database from NVRAM Deleting all va...

Page 122: ...9 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE C0FF Image SHA256 Key source Factory External Mixed Details Export Update Delete Key Exchange Keys Enroll Factory...

Page 123: ...zed TimeStamps Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UE...

Page 124: ...for setup activation key 65535 0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Enabled Disabled Wait for...

Page 125: ...Endless Boot Enable or disable Endless Boot Enabled Disabled Boot Option Priorities Boot Option 1 Select the first second boot device Device Name Disabled Delete Boot Option Remove an EFI boot option...

Page 126: ...http www tyan com 126 3 8 1 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to Delete UEFI Built in EFI Shell...

Page 127: ...it Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Sa...

Page 128: ...Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup opt...

Page 129: ...4 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 130: ...0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x00 Not used Pr...

Page 131: ...mory South Bridge initialization South Bridge module specific 0x1B Pre memory South Bridge initialization South Bridge module specific 0x1C Pre Memory South Bridge initialization South Bridge module s...

Page 132: ...Memory initialization error SPD reading has failed 0x52 Memory initialization error Invalid memory size or memory modules do not match 0x53 Memory initialization error No usable memory detected 0x54 U...

Page 133: ...ialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 CPU DXE initialization CPU module specific 0x68 PCI host bridge initialization 0x69 North Bridge DXE initialization...

Page 134: ...Enumeration 0x95 PCI BUS Request Resources 0x96 PCI Bus Assign Resources 0x97 Console Output devices connect 0x98 Console Input devices connect 0x99 Super IO initialization 0x9A USB initialization is...

Page 135: ...are not available 0xD4 PCI resource allocation error Out of Resources 0xD5 No Space for Legacy Option ROM 0xD6 No Console Output Devices are found 0xD7 No Console Input Devices are found 0xD8 Invalid...

Page 136: ...Code Description 0x40 System is waking up from the S4 sleep state 0xAC System has transitioned into ACPI mode Interrupt controller is in PIC mode 0xAA System has transitioned into ACPI mode Interrupt...

Page 137: ...d A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is lo...

Page 138: ...http www tyan com 138 BIOS Temp Sensor Name Explanation...

Page 139: ...MOSFET DIMM_MOSFET_2 Max Temperature of CPU DIMM Area2 MOSFET P0_UMC0_CH_A Temperature of CPU0 DIMM Channel A P0_UMC1_CH_B Temperature of CPU0 DIMM Channel B P0_UMC3_CH_C Temperature of CPU0 DIMM Cha...

Page 140: ...SYS_FAN_9 Fan Speed of SYS_FAN_9 SYS_FAN_10 Fan Speed of SYS_FAN_10 SYS_FAN_11 Fan Speed of SYS_FAN_11 SYS_FAN_12 Fan Speed of SYS_FAN_12 PSU0_STATUS Current status of PSU0 PSU0_Temp Temperature of PS...

Page 141: ...tch Installation This section provides a step by step demonstration on how to install a M 2 latch 1 Take out the M 2 latch packs from the Accessory Box 2 Insert the M 2 latch into the hole and then tu...

Page 142: ...http www tyan com 142 NOTE The arrow sign on the blue knob is now turned left 3 Push the blue knob slightly to the left as the arrow shows to lock the M 2 card in place...

Page 143: ...http www tyan com 143 4 The installation of the M 2 latch is now complete...

Page 144: ...http www tyan com 144 NOTE...

Page 145: ...serial and parallel ports are built in Bandwidth refers to carrying capacity The greater the bandwidth the more data the bus phone line or other electrical path can carry Greater bandwidth results in...

Page 146: ...ight bits of a byte of data along one wire and receives data on another single wire that is the data is transmitted in serial form one bit after another Parallel ports transmit the bits of a byte on e...

Page 147: ...ware that controls the system hardware Form factor an industry term for the size shape power supply type and external connector type of the Personal Computer Board PCB or motherboard The standard form...

Page 148: ...aster than the ISA bus Local buses are those which operate within a single system as opposed to a network bus which connects multiple systems PCI PIO PCI Programmable Input Output modes the data trans...

Page 149: ...it can keep two sets of memory addresses open simultaneously By transferring data alternately from one set of addresses and then the other SDRAM cuts down on the delays associated with non synchronou...

Page 150: ...oard or joystick port It is fast enough to support video transfer and is capable of supporting up to 127 daisy chained peripheral devices VGA Video Graphics Array the PC video display standard V SYNC...

Page 151: ...prehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find the latest software and operating system componen...

Page 152: ...ed by turning the equipment off and on the user is encouraged to try one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and...

Reviews: