53
http://www.tyan.com
3.2.7 Hardware Health Configuration Sub-Menu
You can use this screen to view the Hardware Health Configuration Settings. Use
the up and down arrow (
Ç
/
È
) keys to select an item. Use the Plus and Minus (+/-)
keys to change the value of the selected option. The settings are described on the
following pages.
BIOS Setup Utility
Main
Advanced
PCI/PnP Boot Security Chipset Exit
Hardware Health Configuration
Auto FAN Control
PWM Minimal Duty Cycle
Hardware Health Event Monitoring
[Disabled]
[50% Duty Cycle]
Sensor Data Register Monitoring
Sensor Event Configuration
Chassis Select
Sensor Name
Sensor Event Status
Sensor ID#
Sensor Event Switch
[Manual ]
[ ]
[No Sensor]
[xx]
FAN power duty cycle is
auto dynamic
programmed in selected
temperature range.
Disabled: Fan Power On.
Enabled: Fan Power
Duty Cycle=50%(32
˚
C)-
100%(0
˚
C), see max
(CPUs, SIO) temperature
←
→
Select Screen
↑↓
Select Item
+/- Change Option
Tab Select Field
F1 General Help
F10 Save and Exit
ESC Exit
Feature
Option
Description
Hardware Health Configuration
Disabled
Auto FAN Control
Enabled
FAN power duty cycle is auto dynamic
programmed in selected temperature
range.
Disabled: Fan Power On.
Enabled: Fan Power Duty Cycle=50%(32
°
C)-100%(0
°
C), see max (CPUs, SIO)
temperature
50% Duty Cycle
40% Duty Cycle
30% Duty Cycle
PWM Minimal Duty
Cycle
0% Duty Cycle
Duty Cycle control range:
50%-100%
40%-100%
30%-100%
0%-100%
Manual
1x4 FAN
1x8 FAN
Chassis Select
Auto
Select chassis type to configure sensor
event default status.
Option [Manual] shows submenu to
configure each sensor event.
Summary of Contents for S7012
Page 4: ...4 http www tyan com NOTE...
Page 14: ...14 http www tyan com J18 From left to right SATA5 SATA4 SATA3 SATA2 SATA1 SATA0 J34 J16 J15...
Page 18: ...18 http www tyan com J35 USB3 J33 JP3 JP2 JP1...
Page 20: ...20 http www tyan com J1 J7 J3...
Page 34: ...34 http www tyan com NOTE...
Page 78: ...78 http www tyan com NOTE...
Page 82: ...82 http www tyan com NOTE...