Chapter 4: SATA/RAID Setup (for SATA RAID model)
4-20
http://www.tyan.com
The boot sector maps the data partition on the disk drive. To delete an array without deleting
the data, press N. This action is sometimes part of a data recovery operation, under the
direction of Technical Support.
After deleting the array, create a new array using Auto Setup (1) or the Define Array (3) from
the Main Menu.
4.5.7 Rebuild a Mirrored Array
Use the Rebuild Array (5) Menu option to recover from an error in a mirrored (RAID 1) disk
array.
Note the Critical Status of the array shown above. If you observe this condition when booting
your system from the FastTrak BIOS, your array needs attention.
Important
Drives MUST be replaced if they contain any physical errors, before
rebuilding the array.
Follow these steps before using the Rebuild Array menu option:
1. Press Ctrl-F to enter FastBuild Main Menu.
2. Press 3 to select Define Array.
3. Press the arrow keys to highlight the failed array and press Enter to select it.
4. In the Array Definition menu, in the Drive Assignments field, identify the failed drive. In the
example above, the drive in Channel 2 has failed.
5. Press Esc twice to Exit the FastBuild Utility.