3.6      Replacing the Front Panel Board ........................................... 69

 

3.6.1      Front Panel Board Specifications .................................... 71

 

3.6.2      Connector Pin Definition.................................................. 72

 

3.7      Replacing the System Fan ..................................................... 73

 

3.8      Replacing the Fan Backplane Board...................................... 75

 

3.8.1      Fan BP Board Specifications........................................... 78

 

3.8.2      Fan BP Board LED Definitions ........................................ 78

 

3.8.3      Connector Pin Definitions ................................................ 79

 

3.9      Replacing the HDD Backplane Board .................................... 80

 

3.9.1      HDD BP Board Specifications ......................................... 81

 

Appendix I: Cable Connection Tables .......................................... 83

 

Appendix II: FRU Parts Table ........................................................ 85

 

Appendix III: Fan and Temp Sensors ........................................... 87

 

Appendix IV: Technical Support ................................................... 91

 

 

Summary of Contents for GN70-B7056

Page 1: ...1 http www tyan com GN70 B7056 Service Engineer s Manual...

Page 2: ...2 http www tyan com...

Page 3: ...bility or warranties relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without notice In...

Page 4: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment i...

Page 5: ...ntroduction to the TYAN GN70 B7056 barebones standard parts list describes the external components gives a table of key components and provides block diagram of the system Chapter2 Covers procedures o...

Page 6: ...e purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet gDo not place anything on the power cord Place the power cord where it...

Page 7: ...ols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Warning This symbol...

Page 8: ...es bent Equipment Racks To avoid injury or damage to the equipment g Observe local occupational health and safety requirements and guidelines for manual materials handling g Do not attempt to move a r...

Page 9: ...ll cause restricted airflow and might cause damage to the equipment g Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable g Ver...

Page 10: ...ttempt to recharge the battery g Dispose of used batteries according to the instructions of the manufacturer Do not dispose of batteries with the general household waste To forward them to recycling o...

Page 11: ...the product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized service provider Examples of damage requiring service include Th...

Page 12: ...http www tyan com 12...

Page 13: ...Motherboard Components 39 2 1 1 Removing the Chassis Cover 39 2 1 2 Removing the Riser Card Brackets 41 2 1 3 Installing the CPU and Heatsink 42 2 1 4 Installing the Memory 45 2 1 4 Installing Hard Dr...

Page 14: ...3 8 Replacing the Fan Backplane Board 75 3 8 1 Fan BP Board Specifications 78 3 8 2 Fan BP Board LED Definitions 78 3 8 3 Connector Pin Definitions 79 3 9 Replacing the HDD Backplane Board 80 3 9 1 HD...

Page 15: ...64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The GN70 B7056 not only empowers your company in nowadays IT demand but also offers a smooth path for future a...

Page 16: ...cy PFC 80 plus gold Redundancy 1 1 Serviceability Hot swap Input Range Full range AC 100 240V Frequency 50 60 Hertz Power Supply Output Watts 770 Watts Supported CPU Series Intel Xeon Processor E5 260...

Page 17: ...cator Fan PSU fail LED indicator System Monitoring Others Chassis intrusion detection Watchdog timer support Onboard Chipset Onboard Aspeed AST2300 AST2300 IPMI Feature IPMI 2 0 compliant baseboard ma...

Page 18: ...5x330mm Buttons 1 RST 1 ID 1 PWR w LED LEDs 1 PWR 1 ID 1 Warning 3 LAN Front Panel I O Ports 2 USB ports Type Q ty 2 5 or 3 5 Hot Swap 8 External Drive Bay HDD backplane support SAS SATA 6 0Gb s Syste...

Page 19: ...r COM 1 DB 9 COM port VGA 1 D Sub 15 pin port I O Ports RJ 45 3 ports Chipset Nuvoton 83773G Voltage Monitors voltage for CPU memory chipset power supply Temperature Monitors temperature for CPU syste...

Page 20: ...e power cord 2 CCBL 0300 EU type power cord TYAN GN70 B7056 B7056G70W8HR 2T Form Factor 2U Rackmount Gross Weight 25 kg Chassis Model GN70 Dimension D x W x H 27 56 x 17 72 x 3 43 700 x 450 x 87mm Mot...

Page 21: ...sets of the following expansion combination 1 PCI E x16 slot w x16 or x8 link 1 PCI E x8 slot w x0 or x8 link 1 PCI E x8 slot Expansion Slots Recommended TYAN Riser Card M7056 L24 3F PCI E x16 2U ris...

Page 22: ...overy User configurable H W monitoring Auto configurable of hard disk types Operating System OS supported list Please visit our web site for the latest update FCC DoC Class A Regulation CE DoC Yes Ope...

Page 23: ...kaged as illustrated below 1 4 1 Box Contents Component Description 2U chassis 8 hot swap HDD bays TYAN S7056 system board pre installed 2 ERP1U 770W power supply unit 4 System fan M1601T70 D PDB Powe...

Page 24: ...to TYAN s website for service http www tyan com The web site also provides information of other TYAN products as well as FAQs compatibility lists BIOS settings etc TYAN Motherboard Drive CD Heatsink...

Page 25: ...http www tyan com 25 Barebone Manual Mainboard Manual Addendum for China Use Only...

Page 26: ...he following views show you the product 1 5 1 System Front View 1 Ears 2 3 5 2 5 HDD bays 3 USB Ports 4 ID Button 5 NMI Button 6 RESET Button 7 LAN1 LAN2 LAN3 8 ID LED 9 System Fan Fail LED 10 System...

Page 27: ...al Off ID LED Located Blue Solid on Local and remote Off line Off Link Solid on LAN1 LAN2 LAN3 Activity Green Blinking PSU Redundancy 1 1 System Warning LED Indication Status System Warning LED 2 PSU...

Page 28: ...LED Color Amber Activity LED Color Green No Driver Present or power disconnected OFF OFF No Activity OFF Solid ON Driver Present Access Activity OFF Blinking HDD Fail Solid ON OFF Rebuild Blinking 4H...

Page 29: ...Scheme Left LED Link Activity Right LED Speed No Link OFF OFF Link Solid Green OFF 10 Mbps Active Blinking Green OFF Link Solid Green Solid Green 100 Mbps Active Blinking Green Solid Green Link Solid...

Page 30: ...n X540 LAN chip is on LAN1 and LAN2 can support up to 100Mbps 10Gbps 3 Peripheral devices can be plugged straight into any of these ports but software may be required to complete the installation ID L...

Page 31: ...available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population gu...

Page 32: ...Port 80 Header J29 IPMB Connector J30 SATA_SGPIO SATA SGPIO Pin Header J33 SAS SMB Pin Header J34 PSMI Connector J39 SSI_FP Front Panel Connector J43 PWR2 SSI 8 pin CPU Power Connector J44 LAN_LED LA...

Page 33: ...http www tyan com 33 1 5 5 System Block Diagram S7056...

Page 34: ...n com 34 1 5 6 Internal View With Riser Card Brackets 1 3 5 2 5 HDD cage underneath 2 SAS SATA HDD Backplane Board 3 System Fan Unit 4 Power Distribution Board 5 PCI E Riser Card Bracket 6 Power Suppl...

Page 35: ...http www tyan com 35 Without Riser Card Brackets 1 3 5 2 5 HDD cage underneath 2 SAS SATA HDD Backplane Board 3 System Fan Unit 4 Power Distribution Board 5 Power Supply underneath...

Page 36: ...http www tyan com 36 NOTE...

Page 37: ...proper tools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following z A cross head Phillips screwdrive...

Page 38: ...touching motherboard components IC chips connectors memory modules and leads z The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static su...

Page 39: ...ents on to the motherboard including CPUs memory modules HDD and PCI E cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove the GN70 B7056 chassis cover 1 Unscrew the rear top co...

Page 40: ...http www tyan com 40 3 Slide the rear top cover out...

Page 41: ...com 41 2 1 2 Removing the Riser Card Brackets Follow these instructions to remove the PCI E Riser Card Brackets 1 Loose three thumb screws to release the PCI E Riser Card Brackets 2 Lift up the Riser...

Page 42: ...on installing CPUs and CPU heatsinks 1 Locate the CPU sockets Always start with CPU0 first 2 Pull the first and second levers slightly away from the socket and then push them to a fully open position...

Page 43: ...http www tyan com 43 4 Place the CPU into the socket and make sure that the gold arrow is located in the right direction...

Page 44: ...Close the CPU socket cover and press the levers down to secure the CPU 6 Position the heatsink on top of the CPU and secure it with 4 screws 7 Repeat the procedures mentioned earlier to install the s...

Page 45: ...herboard 2 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 3 Align the memory module with the slot When inserted properly the memory slot loc...

Page 46: ...http www tyan com 46 Memory Population Option Table The following pictures show common types of DDR3 memory modules...

Page 47: ...are properly utilized providing maximum memory bandwidth 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 4 Dual rank DIMMs are recommen...

Page 48: ...s ensures that all four memory channels are properly utilized providing maximum memory bandwidth 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks...

Page 49: ...NOTE 3 1DPC One dimm per channel NOTE 4 2DPC Two dimm per channel z Supported DRAM Densities are 1Gb 2Gb and 4Gb Only 2Gb and 4Gb are validated by Intel z Command Address Timing is 1N for 1DPC and 2N...

Page 50: ...00 1066 800 NOTE 1 The blue blocks indicate that the DRAM Densities are supported but not validated NOTE 2 The grey blocks indicate that the DRAM Densities are supported and validated NOTE 3 The yello...

Page 51: ...to eight 8 3 5 or 2 5 hard drives Follow these instructions to install a hard drive Warning Always install the hard disk drive to the chassis after the chassis is secured on the rack 1 Press and hold...

Page 52: ...ttp www tyan com 52 Option A for 2 5 hard drives 3 Place a 2 5 hard drive into the HDD tray and use 4 screws to secure the HDD Option B for 3 5 hard drives 4 Unscrew the drive bracket from the HDD tra...

Page 53: ...http www tyan com 53 5 Place a 3 5 hard drive into the drive tray and use 6 screws to secure the HDD 6 Reinsert the HDD tray into the chassis and press the locking lever to secure the tray...

Page 54: ...e GN70 B7056 supports two PCI E Riser Card Brackets A power cable 2x3p 2x4p is required for GPU cards Follow these instructions to install PCI E cards 1 Unscrew the PCI E slot to take out the PCI brac...

Page 55: ...http www tyan com 55 3 Repeat the same procedures for the second Riser Card Bracket...

Page 56: ...the TYAN GN70 B7056 into an industry standard 19 rack NOTE Before mounting the TYAN GN70 B7056 in a rack ensure that all internal components have been installed and that the unit has been fully tested...

Page 57: ...57 http www tyan com 2 Repeat the same procedures for the front end of the rail Front 3 Push the locking latch to secure the rail to the rack Repeat the same procedures for the other rail Left Right...

Page 58: ...to its full length push the locking tab of the rail upward and then the rail can slide freely There are three holes on each rail which are used to hook and secure the chassis 5 Align the studs on the...

Page 59: ...http www tyan com 59 6 Push the chassis back into the rack 7 The installation is now complete...

Page 60: ...k 1 Push the ears to pull the chassis forward 2 Push forward the locking tabs on both rails to unhook the chassis from the rails 3 Follow the steps described earlier in reverse to remove the chassis f...

Page 61: ...ter explains how to replace the pre installed components including the S7056 Motherboard M1709G70 FPB Front Panel Board PCI E Riser Card M1245G70 BP6 8 SATA SAS HDD Board System Fan and Power Supply U...

Page 62: ...nstructions to replace motherboard components including the motherboard 3 4 1 Replacing the PCH Upgrade ROM Kit WARNING The PCH Upgrade ROM Kit is pre installed in the system We strongly recommend tha...

Page 63: ...63 http www tyan com 3 Locate the PCH Upgrade ROM Header on your motherboard 4 Insert the Upgrade ROM Kit in the direction as the arrow shows 5 You have completed the PCH Upgrade ROM Kit installation...

Page 64: ...e GN70 B7056 has two pre installed PCI E 16 riser cards Follow the instructions below to disassemble the M7056 L24 3F and M7056 R24 3F PCI E riser cards 1 Unscrew to take out the PCI E card 2 Unscrew...

Page 65: ...65 http www tyan com 3 Repeat the same procedures for the second Riser Card Bracket 4 Unscrew the M7056 L24 3F riser card to replace a new one if necessary...

Page 66: ...lacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all cables 1 Disconnect the Fan control PSMI and power cables 2 Disconnect t...

Page 67: ...l of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the heatsinks and processors if installed 2 Remove the nine screws securing the motherb...

Page 68: ...w tyan com 3 5 Replacing the Power Distribution Board Follow these instructions to replace the M1601T70 D PDB power distribution board 1 Disconnect all cables 2 Unscrew to replace a new power distribu...

Page 69: ...e Front Panel Board Follow these instructions to replace the M1709G70 FPB Front Panel Board 1 Unscrew to release the Front Panel Board Module 2 Push the Front Panel Board Module forward 3 Disconnect t...

Page 70: ...70 http www tyan com 4 Unscrew the Front Panel Board to replace a new one 5 Follow the steps described earlier in reverse to reinstall the Front Panel Board...

Page 71: ...r 18 5MMx44 2MM 4 Layer PCB Connectors One 2x15 pin header for front panel connector of motherboard and HDD backplane board LEDs Power On Off Button with LED Green ID LED Color Blue System Warning LED...

Page 72: ...LED 5 6 ID_LED HD LAN3_LED 7 8 SYS_FAULT1 HD LAN3_LED 9 10 SYS_FAULT2 PWR_SW 11 12 LAN1_LED PWR_SW 13 14 LAN1_LED RESET 15 16 ICH_SMBDAT RESET 17 18 ICH_SMBCLK ID_SW 19 20 INTRU Temp_sensor 21 22 LAN2...

Page 73: ...com 3 7 Replacing the System Fan Follow these instructions to replace the system fan 1 Press the latch in the direction as shown to lift up the fan from cage 2 Take out the fan unit 3 Loose the screw...

Page 74: ...tyan com 4 Push the latch in the direction as the arrow shown to release the fan from the iron holder 5 Remove the iron holder to replace a new fan 6 After replacing a new one put the fan unit back in...

Page 75: ...ollow these instructions to replace the M1806G70 FB Fan Backplane Board in your system 1 Press the latch in the direction as shown to lift up the fan from cage 2 Remove all four fans from the chassis...

Page 76: ...76 http www tyan com 4 Use a screw driver to unscrew the Fan Module 5 Disconnect the power and fan cables 6 Lift up the Fan Module...

Page 77: ...77 http www tyan com 7 Release the 14 screws on the Fan Backplane Board to replace a new one 8 Follow the steps described in reverse order to reinstall the fan cage...

Page 78: ...plane Board in details Form Factor 254 mm x 82 mm 4 layer PCB Integrated I O 2 1x4pin R A Power Connector 8 2x2pin Fan Connectors 1 2x10pin Barebone Fan Connector 1 2x2pin Connector for S7015 3 8 2 Fa...

Page 79: ...12V 1 2 GND GND 3 4 5V Barebone Fan Connector J9 Definition Pin Pin Definition FANIN1 1 2 FANIN6 FANIN2 3 4 FANIN7 FANIN3 5 6 FANIN8 FANIN4 7 8 SIO_FANIN1 FANIN5 9 10 SIO_ FANIN2 GND 11 12 Key MB_PWM...

Page 80: ...DD Backplane Board 1 Refer to Section 3 8 Replacing the Fan Backplane Board for how to remove the Fan Module Disconnect the power cables attached to the HDD BP Board 2 Unscrew the HDD BP Board Remove...

Page 81: ...s Front View Rear View with mylar Form Factor 81 8 x 436 mm 4 layer PCB Integrated I O 8 SAS HDD Connectors 2 Mini SAS Connectors to MB and RAID Card 1 2 x 4 pin Power Connector LEDs 8 HDD active LEDs...

Page 82: ...installed CPSU 0470 ERP1U 770W Power Supply Units Follow these instructions to replace the power supply units 1 Press and hold the latch to pull the power supply out 2 After replacing a new power sup...

Page 83: ...e Front Panel Board M1709G70 FPB Connects to Motherboard J3 J39 4 USB Cable Front Panel Board M1709G70 FPB Connects to Motherboard J1 J26 5 Power Cables Power Board M1601T70 D PDB Connects to Motherbo...

Page 84: ...http www tyan com 84 NOTE...

Page 85: ...38mm 4pin Heatsink CHSK 0590 343T43900001 CPU 1U Passive heatsink M7056 R24 3F 412100000214 PCI E x16 2U Riser Card PCBA M7056 L24 3F 412100000213 PCI E x16 2U Riser Card Rack Mounting CRAL 0190 452T4...

Page 86: ...http www tyan com 86 NOTE...

Page 87: ...explanation is also included for readers reference NOTE The red dot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor SYS_FAN_1 SYS_FAN_2 SYS_FAN_3 and SYS_FAN_4 They detect the fan spee...

Page 88: ...88 http www tyan com BIOS Temp Sensor Name Explanation...

Page 89: ...rature of the PCH Area M B_Inlet_Temp Temperature of the M B Air Inlet Area LAN_Temp Temperature of the LAN Chip Area GPU0_Temp Temperature of GPU0 GPU1_Temp Temperature of GPU1 PSU1_Temp Temperature...

Page 90: ...lot CPU1_DIMM_C1 Temperature of CPU1 DIMM C1 Slot CPU1_DIMM_D0 Temperature of CPU1 DIMM D0 Slot CPU1_DIMM_D1 Temperature of CPU1 DIMM D1 Slot BIOS FAN Sensor Name Explanation SYS_FAN_1 Fan speed of SY...

Page 91: ...ectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for...

Page 92: ...roper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manu...