5.3.7.2   COM2 Console Redirection Settings 

 

 
Terminal Type 

Emulation: ANSI: Extended ASCII char set. VT100: ASCII char set.   
VT100+: Extends VT100 to support color, function keys, etc.   
VT-UTF8: Uses UTF8 encoding to map Unicode chars onto 1 or more bytes.

 

VT100+

 

VT100 / VT-UTF8 / ANSI   

 
Bits per Second 

Select serial port transmission speed. The speed must be matched on the other side. 
Long or noisy lines may require lower speeds. 

38400

 / 

9600 / 19200 / 57600 / 

115200

 

 
Data Bits 

8 / 

 
Parity 

A parity bit can be sent with the data bits to detect some transmission errors. Even: 
parity bit is 0 if the num of 1’s in the data bits is even. Odd: parity bit is 0 if the num of 
1’s in the data bits is odd. Mark: parity bit is always 1. Space: parity bit is always 0. 
Mark and Space parity do not allow for error detection. 

None / 

Even / Odd / Mark / Space 

 

Summary of Contents for B7126G68AV10E2HR

Page 1: ...1 http www tyan com GC68 A B7126 GC68A B7126 Service Engineer s Manual...

Page 2: ...rranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event wi...

Page 3: ...se limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio freq...

Page 4: ...oard Do not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufactur...

Page 5: ...ules hard drivers and other optional parts Chapter 3 Replacing the Pre installed Components This chapter covers the removal and replacement procedures for pre installed components Chapter 4 Motherboar...

Page 6: ...n to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on th...

Page 7: ...d Consult equipment documentation for specific details Caution Slide mounted equipment is not to be used as a shelf or a work space Warning This symbol indicates the presence of hazardous energy circu...

Page 8: ...register Never use the product in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages...

Page 9: ...idth and depth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack...

Page 10: ...Equipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns Do not disassemble crush puncture short external c...

Page 11: ...l components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring...

Page 12: ...http www tyan com 12...

Page 13: ...6 2 1 Installing Motherboard Components 37 2 1 1 Removing the Chassis Cover 37 2 1 2 Replacing the Chassis Cover 39 2 1 3 Installing the CPU and Heat sink 41 2 1 4 Installing the Memory 45 2 1 5 Insta...

Page 14: ...4 4 Board Parts Jumpers and Connectors 95 4 5 LED Definitions 110 4 6 Installing the Processor and Heat sink 112 4 7 Tips on Installing Motherboard in Chassis 115 4 8 Installing the Memory 117 4 9 Att...

Page 15: ...SI Configuration 226 5 3 27 VLAN Configuration MAC Address 233 5 3 28 MAC Address IPv4 Network Configuration 235 5 3 29 MAC Address IPv6 Network Configuration 236 5 3 30 Intel I210 Gigabit Network Con...

Page 16: ...dix I How to recover UEFI BIOS 285 Appendix II Installing IO Plate for OCP Card 287 Appendix III Cable Connection Tables 289 Appendix IV Fan and Temp Sensors 293 Appendix V FRU Parts Table 299 Appendi...

Page 17: ...uting high bandwidth memory design and lightning fast PCI E bus implementation The GC68 A B7126 not only empowers your company in nowadays IT demand but also offers a smooth path for future applicatio...

Page 18: ...8AV10E2HR dual socket 3rd Gen Intel Xeon Scalable processor with TDP 205W barebone platform with 2 hot swap 2 5 SAS SATA NVMe 10 hot swap 2 5 SAS SATA devices B7126G68V4E4HR dual socket 3rd Gen Intel...

Page 19: ...ation FAN 6 4cm fans Power Supply Type RPSU Input Range AC 100 240V 12 6A Frequency 50 60 Hz Output Watts 850 Watts Efficiency 80 plus Platinum Redundancy 1 1 Serviceability Hot swap Processor Q ty So...

Page 20: ...C Support Yes Graphic Connector type D Sub 15 pin Resolution Up to 1920x1200 Chipset Aspeed AST2500 I O Ports USB 1 USB3 0 ports front 2 USB3 0 ports rear COM 1 DB 9 COM port VGA 1 D Sub 15 pin port R...

Page 21: ...6 Compliant Yes Package Contains Barebone 1 GC68 A B7126 Barebone Manual 1 Quick Installation Guide GC68A B7126 B7126G68AV10E2HR System Form Factor 1U Rackmount Chassis Model GC68A Dimension D x W x H...

Page 22: ...mory voltage 1 2V Expansion Slots PCIe 2 PCIe Gen 4 x16 slots FH HL Pre installed TYAN Riser Card PCIe Gen 3 1 M7126 L16 1F riser card for 1 PCIe Gen 4 x16 slot 1 M7126 R16 1F riser card for 1 PCIe Ge...

Page 23: ...ure IPMI 2 0 compliant baseboard management controller BMC 10 100 1000 Mb s MAC interface BIOS Brand ROM size AMI 32MB Feature Hardware Monitor Boot from USB device PXE via LAN Storage Console Redirec...

Page 24: ...e installed M1724G68 FPB Front Panel Board pre installed M1725G68 USB Front Panel Board pre installed M7126 R16 1F 1U PCI E Riser pre installed M7126 L16 1F 1U PCI E Riser pre installed M1631G68 D 85A...

Page 25: ...heatsinks CPU Air Duct US Power Cords EU Power Cords Screw Pack for OCP2 0 LAN Mezzanine 1 M 2 Board Clip OCP I O Plate w Gasket for dual port RJ45 LAN Mezzanine OCP I O Plate for dual port SFP28 SFP...

Page 26: ...g views show you the product 1 5 1 System Front View GC68A B7126 B7126G68AV10E2HR GC68 A B7126 B7126G68V4E4HR No Description No Description 1 USB3 0 Port M1725G68 USB pre installed 3 Power Button with...

Page 27: ...r Off All Off System Warning Red Solid On ID Button Blue ID Located Blue Solid On HDD LED Definitions Drive Status Activity LED Green Status LED Red Drive present no activity Green Solid On Off Drive...

Page 28: ...dedicated for IPMI USB3 0 Ports 4 VGA Port 5 Serial Port COM1 6 LAN2 7 LAN1 8 OCP Card Area 9 ID LED 10 ID Button 11 Expansion Slots Half height Half length PCI E Gen 4 x16 card w tall bracket x2 Rear...

Page 29: ...tem operation normally one of PSU or AC cord be unplug 1 1 PSU redundancy fail Amber Solid On 1Gbps LAN Port Indications 1Gbps LAN Link Activity LED Scheme Left LED Link Activity LED Color Green Right...

Page 30: ...M1725G68 USB pre installed 5 PSU0 2 M1724G68 FPB pre installed 6 PSU1 3 2 5 SSD HDD Trays 7 3 4028 3 4056 fans 4 M1631G68 D 85A PDB pre installed 8 Riser Card Bracket M7126 R16 1F M7126 L16 1F pre in...

Page 31: ...stalled 5 PSU0 2 M1724G68 FPB pre installed 6 PSU1 3 2 5 3 5 SSD HDD Trays 7 3 4028 3 4056 fans 4 M1631G68 D 85A PDB pre installed 8 Riser Card Bracket M7126 R16 1F M7126 L16 1F pre installed NOTE M13...

Page 32: ...http www tyan com 32 1 5 5 Chassis Dimensions...

Page 33: ...http www tyan com 33 1 5 6 Block Diagram S7126...

Page 34: ...http www tyan com 34 1 5 7 Board Image S7126 NOTE Please refer to Tyan S7126 User Guide for more MB details...

Page 35: ...ou from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdriver A grounding strap or an an...

Page 36: ...metal chassis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre install...

Page 37: ...s how to install components on to the motherboard including CPUs memory modules and add on cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove the GC68 A B7126 chassis cover 1 U...

Page 38: ...http www tyan com 38 3 Slide to lift up the rear top cover 4 Slide out the drive trays Unscrew the front top cover and then slide it forwards to lift it up...

Page 39: ...replace the GC68 A B7126 chassis cover 1 Place the front top cover on the chassis and slide it backwards Secure the front top cover with two screws and then insert the HDD drives into the chassis 2 Pl...

Page 40: ...http www tyan com 40 4 Use a screw driver to fasten the rear top cover...

Page 41: ...hitley platform for Ice lake series CPU The following installation is based on an Intel LGA4189 socket 1 Take out the CPU carrier and processor 2 Align the triangle guide pin with the gold arrow guide...

Page 42: ...the triangle edge of the carrier with the notch on the edge of the heatsink Then install the carrier on the bottom of the heatsink and make sure the latches are snapped under the edge of the heatsink...

Page 43: ...ide pins Make also sure that the triangle edge of the carrier is aligned correctly with the triangle mark on the CPU socket Then place the heatsink assembly onto the top of the CPU socket 7 Press down...

Page 44: ...with its respective slot and then hook the tab of the air duct to the fan cage Push the air duct down until it is fully seated Repeat the same procedures to install another air duct NOTE A new heatsi...

Page 45: ...http www tyan com 45 2 1 4 Installing the Memory Follow these instructions to install the memory modules onto the motherboard 1 Unlock the clips 2 Insert the memory module 3 Lock the clips...

Page 46: ...http www tyan com 46 Memory Population table...

Page 47: ..._DIM_CH_E0 or P0_MC1_DIM_CH_C0 P0_MC3_DIM_CH_G0 4 DIMMs P0_MC0_DIM_CH_A0 P0_MC1_DIM_CH_C0 P0_MC2_DIM_CH_E0 P0_MC3_DIM_CH_G0 or P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_H0 6 DIM...

Page 48: ...nstalled 2 4 6 8 10 12 14 16 P0_MC0_DIM_CH_A0 P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_C0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_E0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_G0 P0_MC3_DIM_CH_H0 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_B0 P...

Page 49: ...p www tyan com 49 2 1 5 Installing the Expansion Card Follow these instructions to install the expansion card 1 Loosen two screws to take out the riser card bracket 2 Unscrew to remove the dummy brack...

Page 50: ...http www tyan com 50 3 Insert the expansion card into the riser card bracket and secure with a screw 4 Replace the Riser Card Bracket into the chassis...

Page 51: ...ing the 2 5 Hard Drive Follow these instructions to install the 2 5 hard drives for B7126G68AV10E2HR SKU 1 Press the locking tab to pull the lever open 2 Slide the drive tray out 3 Press the locking t...

Page 52: ...http www tyan com 52 4 Align the hard drive with the guide pins and install the hard drive into the drive tray Close the tray side rail...

Page 53: ...http www tyan com 53 5 Insert the drive tray into the chassis and close the lever...

Page 54: ...Drives Follow these instructions to install the slim 2 5 hard drives for B7126G68V4E4HR SKU 1 Press the locking tab to pull the lever open 2 Slide the drive tray out 3 Align the hard drive with the gu...

Page 55: ...http www tyan com 55 4 Insert the drive tray into the chassis and close the lever...

Page 56: ...yan com 56 2 1 8 Installing the 2 5 3 5 Hard Drives Follow these instructions to install the 2 5 3 5 hard drives for B7126G68V4E4HR SKU 1 Press the locking tab to pull the lever open 2 Slide the drive...

Page 57: ...http www tyan com 57 Option 1 2 5 hard drive 3 Place a 2 5 SSD into the drive tray 4 Flip the drive tray over and use a screw driver to secure the hard drive...

Page 58: ...rive 5 To install a 3 5 hard drive pull the tray side rail open 6 Align the hard drive with the guide pins and install the hard drive into the drive tray Close the tray side rail 7 Insert the drive tr...

Page 59: ...ling the M 2 Latch Follow these instructions to install the M 2 Latch 1 Take out the M 2 Latch from the AK box 2 Measure the length of the M 2 card and insert the latch into the appropriate hole 3 Tur...

Page 60: ...http www tyan com 60 4 Insert the M 2 card into the slot Pull the latch to lock the M 2 card...

Page 61: ...plied rack mounting kit Rack mounting kit Rails x 2 Screw Sacks x 2 2 2 1 Installing the Server in a Rack Follow these instructions to mount the GC68 A B7126 into an industry standard 19 rack Note Bef...

Page 62: ...ails to the Rack 1 Take out the rails from the accessory kit 2 Push the white tab in the direction as the arrow shows to draw out the inner rail 3 Attach the inner rails to both sides of the chassis P...

Page 63: ...then push the inner rail forwards to unlock 4 Attach the outer rail to the rack Pull the latch open and align the square stud with the square hole on the rack rail Please note that the square stud mus...

Page 64: ...http www tyan com 64 Front...

Page 65: ...w out the rails half way and then slide the chassis into the rails Must be done with at least 2 people Properly place the chassis directly on the rack and install 2 Slide in the chassis half way to th...

Page 66: ...http www tyan com 66 3 Fasten the chassis ear to the front surface of chassis...

Page 67: ...ase the chassis ears by loosening the screws 2 Pull out the chassis half way to the lock position Push the white locking tabs forward to slide the chassis all out from the rack Caution Remove the serv...

Page 68: ...http www tyan com 68 NOTE...

Page 69: ...ce the pre installed components including the S7126 Motherboard M1724G68 FPB Front Panel Board M7126 L16 1F and M7126 R16 1F Riser Cards 3 HDD Backplane Boards M1631G68 D PDB Power Distribution Board...

Page 70: ...the cover of GC68 A B7126 3 4 Replacing the Power Supply To replace the power supply follow these instructions 1 Press the latch as shown to pull out the power supply module 2 Replace a new single pow...

Page 71: ...oard 1 Loosen 3 screws to release the front panel bezel from the chassis 2 Loosen 2 screws to remove the front panel cage and bracket 3 Disconnect the cable and unscrew the Front Panel Board 4 After r...

Page 72: ...http www tyan com 72 3 5 1 Front Panel Board Features Front View Rear View M1724G68 FPB Front Panel Board Form Factor 33 5 21 1 6 mm Integrated I O 1 Signal Connector J1 1 PWR Button 1 ID Button...

Page 73: ...USB Board 1 Loosen 3 screws to release the front USB bezel from the chassis 2 Loosen 2 screws to remove the USB cage and bracket 3 Disconnect the cable and unscrew the USB Board 4 After replacing wit...

Page 74: ...http www tyan com 74 3 6 1 USB Board Features Front View Rear View M1725G68 USB Front Panel Board Form Factor 31 9 19 4 1 6 mm Integrated I O 1 Signal Connector J2 1 USB3 0 Connector...

Page 75: ...ructions to replace the HDD Backplane Boards B7126G68V4E4HR SKU M1312G68 BP6E 4X M1302G68 BP12 4 pre installed 1 Slide out the hard drive trays 2 Disconnect all cables connected to the M1312G68 BP6E 4...

Page 76: ...ackplane Board Use a screw driver to loosen two screws 4 Lift up the M1302G68 BP12 4 HDD Backplane Board to get off the hook 5 After replacing with new HDD Backplane Boards follow the procedures descr...

Page 77: ...G68A BP12E 12X HDD Backplane Board 2 Use a screwdriver to unscrew the M1303G68A BP12E 12X HDD Backplane Board 3 Lift up the HDD Backplane Board to get off the hook 4 After replacing with new HDD Backp...

Page 78: ...SKU Form Factor 435 38 3 2 6 mm Integrated I O PCI EGen3 12 pot 2 5 12G SATA SAS NVMe BP Board 2 Hot swap 2 5 SAS 12G SATA 6G NVMe devices 10 Hot swap 2 5 SAS 12G SATA 6G HDD SSD 2 ATX 2x4 pin Power...

Page 79: ...r B7126G68V4E4HR SKU Form Factor 433 95 38 2 2 6 mm Integrated I O PCI EGen3 4 port 3 5 2 5 HDD BP Board supports 4x SATA 6G s SAS 12Gb s 1 Big 4 pin Power Connector PW2 1 ATX 4x2 pin Power Connector...

Page 80: ...Backplane Board for B7126G68V4E4HR SKU Form Factor 303 40 1 1 6 mm Integrated I O PCI EGen3 4 port 2 5 slim HDD BP Board 4 Hot swap slim SATA 6Gb s SSD or 4 hot swap slim 2 5 NVMe U 2 1 ATX 8 pin Pow...

Page 81: ...tion Board 1 Pull the power supply modules slightly away from the chassis Release cable ties and disconnect all cables from the Power Distribution Board 2 Unscrew to replace the M1631G68 D 85A PDB Pow...

Page 82: ...ww tyan com 82 3 7 1 Power Distribution Board Features M1631G68 D 85A PDB Power Distribution Board Form Factor 171 108 1 6 mm Specifications 1 ATX24P 2 ATX8P 1 HDD 4P PWR 2 DOM 5V PWR 1 PMBUS 2 Micro...

Page 83: ...itions Location Definition J2 J3 PWR1 PW2 PW5 PW3 PW4 PW6 PW1 DOM_5V_PW1 DOM_5V_PW2 Power supply slot Power supply slot ATX Power 12x2 ATX Power 4x2 ATX Power 4x2 HDD Power 4x1 Micro ATX Power 4x2 Mic...

Page 84: ...1F and M7126 R16 1F Riser Cards 1 Lift up the Riser Card Bracket from the chassis Unscrew to replace with a new riser card M7126 L16 1F 2 Unscrew to replace with a new riser card M7126 R16 1F 3 Follo...

Page 85: ...1 2 W x 122 95 D x 1 6 T mm Specification PCI E x16 Gen4 adapter card 1 PCI E x16 Gen4 slot support 1 PCI E x16 Add on card M7126 R16 1F Riser Card Form Factor 30 7 W x 122 95 D x 1 6 T mm Specificati...

Page 86: ...these instructions to replace the fan module 1 Disconnect the fan PWR cable 2 Lift up the fan module from the chassis 3 Release the rubber screws and push pins from the fan module Replace with a new f...

Page 87: ...http www tyan com 87 4 Place the new fan module into the chassis and reconnect the fan cable Remember to tie cables after fan replacement...

Page 88: ...com 88 3 10 Replacing the Motherboard After removing all of the aforementioned components follow these instructions to remove the motherboard from the chassis 1 Release the cable tie and disconnect a...

Page 89: ...http www tyan com 89 2 Unscrew the motherboard to lift it up for replacement...

Page 90: ...http www tyan com 90 NOTE...

Page 91: ...t conditions MITAC recommends wearing a static safety wrist strap 2 Hold the motherboard by its edges and do not touch the bottom of the board or flex the board in any way 3 Avoid touching the motherb...

Page 92: ...tp www tyan com 92 4 1 Board Image S7126 This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above pictu...

Page 93: ...http www tyan com 93 4 2 Block Diagram S7126 Block Diagram...

Page 94: ...http www tyan com 94 4 3 Mainboard Mechanical Drawing...

Page 95: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Page 96: ...5 SSATA_SGPIO1 29 CPU0_FAN CPU0_FAN 12 COM2 header HD_COM2 30 SSI 8 pin CPU0 Power connector PW1 13 Power BTN PWR_BTN 31 FRONT FAN_2 SYS_FAN_2 14 FAN pin header FAN_HD1 32 FRONT FAN_1 SYS_FAN_1 15 Int...

Page 97: ...ctive LED HDD_LED1 XXII Memory Error LED CPU0 LED66 VIII CPU ERROR LED ERR_LED1 XXIII Memory Error LED CPU0 LED65 IX CPU ERROR LED CAT_LED1 XXIV Memory Error LED CPU0 LED61 X CPU ERROR LED ERR_LED0 XX...

Page 98: ...PWER VCC3_Aux KEY 3 4 FP_ID_LED_PW FP_PW_LED_GND 5 6 FP_ID_LED_N HDD_LED_PW 7 8 BMC_HW_FAULT_N HDD_ACT_LED_N 9 10 BMC_SYS_FAULT_N FP_PWR_BTN_N 11 12 LAN0_LED_P GND 13 14 LAN0_LED_N FP_RST_BTN_JP_N 15...

Page 99: ...Fan Connector Reserved for Barebone Signal Pin Pin Signal TACH1 1 2 TACH6 TACH2 3 4 TACH7 TACH3 5 6 TACH8 TACH4 7 8 TACH9 TACH5 9 10 TACH10 GND 11 12 KEY PWM2 13 14 PWM1 TACH11 15 16 SDA TACH12 17 18...

Page 100: ...7 8 HD_VGA_B GND 9 10 HD_VGA_DAT HD_VGA_HS 11 12 KEY HD_VGA_CLK 13 14 HD_VGA_VS HD_COM2 COM Port Header Signal Pin Pin Signal COM2_DCD 1 2 COM2_DSR COM2_RXD 3 4 COM2_RTS COM2_TXD 5 6 COM2_CTS COM2_DT...

Page 101: ...nal GND 1 2 3 4 FP_RST_BTN_N sSATA4 7 pin Vertical SATA Connector PIN Define Pin Connects to the Serial ATA ready drives via the Serial ATA cable 1 GND 2 SSATA4_TXP_C 3 SSATA4_TXN_C 4 GND 5 SSATA4_RXN...

Page 102: ...have forgotten your system setup password or need to clear system BIOS setting 1 Power off the system and disconnect power connectors from the motherboard 2 Press the button Clear CMOS 3 Reconnect pow...

Page 103: ...RX_N 29 30 P12V_IN PCH_PE1_M2_1_RX_P 31 32 P12V_IN GND 33 34 P12V_IN PCH_PE1_M2_1_TX_N 35 36 P12V_IN PCH_PE1_M2_1_TX_P 37 38 NC GND 39 40 M2_SMB_CLK_R PCH_PE0_M2_0_RX_N 41 42 M2_SMB_DAT_R PCH_PE0_M2_0...

Page 104: ...3 GND SSATA1_RXP_C A4 B4 SSATA0_RXP_C SSATA1_RXN_C A5 B5 SSATA0_RXN_C GND A6 B6 GND SSATA3_RXP_C A7 B7 SSATA2_RXP_C SSATA3_RXN_C A8 B8 SSATA2_RXN_C GND A9 B9 GND SSGPIO_DO_0R C1 D1 SSGPIO_DI_0R GND C2...

Page 105: ...C4 D4 SATA0_TXP_C SATA1_TXN_C C5 D5 SATA0_TXN_C GND C6 D6 GND SATA3_TXP_C C7 D7 SATA2_TXP_C SATA3_TXN_C C8 D8 SATA2_TXN_C GND C9 D9 GND NC_PCH_SATA_0 7_A10 A10 B10 GND SGPIO_SATA_CLK A11 B11 SGPIO_SAT...

Page 106: ...2_ABCD_RX_DN3 A17 B17 CPU1_PE2_ABCD_TX_DP3_C CPU1_PE2_ABCD_RX_DP3 A18 B18 CPU1_PE2_ABCD_TX_DN3_C GND A19 B19 GND SlimSAS2 Vertical Slim SAS Connector Signal Name Pin Pin Signal Name GND A1 B1 GND CPU1...

Page 107: ...DN11 A17 B17 CPU1_PE2_ABCD_TX_DP11_C CPU1_PE2_ABCD_RX_DP11 A18 B18 CPU1_PE2_ABCD_TX_DN11_C GND A19 B19 GND SlimSAS4 Vertical Slim SAS Connector Signal Name Pin Pin Signal Name GND A1 B1 GND CPU1_PE2_A...

Page 108: ...M PORT2 Default Pin2 3 closed BMC CONSOLE PORT5 J119 BMC COM Port Jumper Signal Pin Pin Signal BMC_COM2_TXD 1 2 TXD_2 BMC_COM5_TXD 3 Pin1 2 closed BMC COM PORT2 Default Pin2 3 closed BMC CONSOLE PORT5...

Page 109: ...in Pin Signal 1KK to VCC3_AUX 1 2 10K to GND Pin1 2 closed PP PECI to BMC Default Pin1 2 open NI PECI to PCH J120 System Buzzer Jumper VCC5_BZ 1 2 NA BUZ_1 3 4 BUZ_2 Pin3 4 closed Normal Mode Default...

Page 110: ...uts off when the BMC controller cannot be detected or properly initiated Blinking Green The LED blinks per second to indicate that the BMC controller is working normally P0_PG_LED1 CPU0 PWOK LED Pin S...

Page 111: ...ate Description OFF OFF The LED shuts off when the PSU is normal ON Green The LED lights up when the PSU is abnormally ID_LED1 Rear ID LED Pin Signal VCC3_AUX GND State Description OFF OFF OFF ON Gree...

Page 112: ...nstallation for Intel LGA4189 Socket Follow the steps below to install the processors and heat sinks NOTE Please save and replace the CPU protection cap when returning for service 1 Align the triangle...

Page 113: ...ng an alcohol solvent Then apply new thermal grease before reinstalling the heatsink 3 Remove the CPU cover 4 Carefully flip the heatsink assembly Align the heatsink with the CPU socket by the guide p...

Page 114: ...30 Security Torx to tighten the screws in a sequential order 1 2 3 4 NOTE When disassembling the heatsink loosen the screws in reverse order 4 3 2 1 NOTE Always check with the manufacturer of the heat...

Page 115: ...ply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard will...

Page 116: ...http www tyan com 116...

Page 117: ...eight channel memory interfaces supporting DDR4 and Intel OptaneTM PMem memory technology Each channel consists of 64 data and 8 ECC bits Each channel supports up to two DIMMs Support is provided for...

Page 118: ...d across different sockets Mixing of RDIMMs and LRDIMMs is not allowed in the same channel across different channels and across different sockets Mixing of PMem module with RDIMMs is supported in Whit...

Page 119: ...at least one DDR4 DIMM per socket If only one DIMM is populated in a channel then populate it in the slot furthest away from CPU of that channel Always populate the DIMM with the higher electrical loa...

Page 120: ...at least one DDR4 If only one DIMM is populated in a channel then populate it in the slot furthest away from CPU of that channel Always populate the DIMM with the higher electrical loading on a chann...

Page 121: ...ng only applies to 1LM mode SNC and Hemi UBS apply only to 1LM MM volatile region Note 2 Intel OptaneTM PMem 200 series ADx1 non interleave supports fall back to each 8 x configs with Intel OptaneTM P...

Page 122: ...http www tyan com 122 DIMM Location...

Page 123: ..._DIM_CH_E0 or P0_MC1_DIM_CH_C0 P0_MC3_DIM_CH_G0 4 DIMMs P0_MC0_DIM_CH_A0 P0_MC1_DIM_CH_C0 P0_MC2_DIM_CH_E0 P0_MC3_DIM_CH_G0 or P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_H0 6 DIM...

Page 124: ...installed 2 4 6 8 10 12 14 16 P0_MC0_DIM_CH_A0 P0_MC0_DIM_CH_B0 P0_MC1_DIM_CH_C0 P0_MC1_DIM_CH_D0 P0_MC2_DIM_CH_E0 P0_MC2_DIM_CH_F0 P0_MC3_DIM_CH_G0 P0_MC3_DIM_CH_H0 P1_MC0_DIM_CH_A0 P1_MC0_DIM_CH_B0...

Page 125: ...nstructions to install memory modules into the S7126 1 Unlock the clips as shown in the illustration 2 Insert the memory module firmly into the socket by gently pressing down until it sits flush with...

Page 126: ...are very simple There is no need to set Master Slave jumpers on SATA drives If you are in need of SATA SAS cables or power adapters please contact your place of purchase The following pictures illust...

Page 127: ...the card firmly Do not force any add in cards into any slots if they do not seat in place It is better to try another slot or return the faulty card rather than damaging both the motherboard and the a...

Page 128: ...equired to complete the installation Onboard LAN LED Color Definition The five 5 onboard Ethernet ports have green and yellow LEDs to indicate LAN status The chart below illustrates the different LED...

Page 129: ...X_PS_ON_N GND 5 17 GND VCC5 6 18 GND GND 7 19 GND ATX_PG 8 20 NC_PWR1_20 VCC5_SB 9 21 VCC5 P12V_IN 10 22 VCC5 P12V_IN 11 23 VCC5 VCC3 12 24 GND PW1 8 PIN Power Connector Signal Pin Pin Signal GND 1 5...

Page 130: ...properly especially IDE cables and most importantly jumpers You may have difficulty powering on your system if the motherboard jumpers are not set correctly In the rare circumstance that you have expe...

Page 131: ...and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup program...

Page 132: ...or best performance and reliability Even a seemingly small change to the Chipset setup options may cause the system to become unstable or unusable 3 1 4 Setup Variations Not all systems have the same...

Page 133: ...r options that can directly be changed within the Main Setup screen System Language Choose the system default language English Simplified Chinese Japanese System Date Set the Date Use Tab to switch be...

Page 134: ...The HII network drivers displayed here depend on the card s you installed and the functions you enabled Option ROM Dispatch Policy Option ROM Dispatch Policy S5 RTC Wake Settings Enable system to wake...

Page 135: ...s SATA Configuration SATA devices and settings PCH Configuration SATA Device Information Miscellaneous Configuration Miscellaneous Configuration Runtime Error Logging Press Enter to view or change the...

Page 136: ...Configuration MAC XXXXXXXXXXXX VLAN Configuration MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV4 Network Configuration Configure network parameters MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV6 Network Configuration...

Page 137: ...XX IPV4 Network Configuration Configure network parameters MAC XXXXXXXXXXXX MAC XXXXXXXXXXXX IPV6 Network Configuration Configure IPV6 network parameters MAC XXXXXXXXXXXX Driver Health Provides Health...

Page 138: ...has UEFI X Legacy Embedded ROM s VIDx8086 DIDx1533 s0 Bx2 Dx0 Fx0 Enabled Disabled On Board LAN2 I210 Onboard Device has UEFI X Legacy Embedded ROM s VIDx8086 DIDx1533 s0 Bx3 Dx0 Fx0 Enabled Disabled...

Page 139: ...l wake on the day hr min sec specified Disabled Fixed Time Dynamic Time When Wake system from S5 is set to Fixed Time Wake up hour Select 0 23 For example enter 3 for 3am and 15 for 3pm Wake up minute...

Page 140: ...m 140 5 3 3 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available...

Page 141: ...ACPI Auto Configuration Enable or Disable BIOS ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or Disable System ability to Hibernate OS S4 Sleep State This option may not be effec...

Page 142: ...ww tyan com 142 5 3 5 AST2500 Super IO Configuration Super IO Chip Read only Serial Port 1 Configuration Set Parameters of Serial Port 1 COMA Serial Port 2 Configuration Set Parameters of Serial Port...

Page 143: ...rt Enable or disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12...

Page 144: ...rt Enable or disable Serial Port COM Enabled Disabled Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12...

Page 145: ...http www tyan com 145 5 3 6 Power Management CPU Power and Performance Policy CPU Power and Performance Policy Performance Balanced Power Power...

Page 146: ...S Console redirection enable or disable Disabled Enabled Legacy Console Redirection Settings Legacy Console redirection settings Console Redirection Settings The settings specify how the host computer...

Page 147: ...erial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with...

Page 148: ...nt to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Ke...

Page 149: ...erial port transmission speed The speed must be matched on the other side Long or noisy lines may require lower speeds 38400 9600 19200 57600 115200 Data Bits 8 7 Parity A parity bit can be sent with...

Page 150: ...nt to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop signal None Hardware RTS CTS VT UTF8 Combo Ke...

Page 151: ...COM2 Resolution On Legacy OS the Number of Rows and Columns supported redirection 80x24 80x25 Redirect After POST When BootLoader is selected then Legacy Console Redirection is disabled before booting...

Page 152: ...rver OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Se...

Page 153: ...g data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires...

Page 154: ...r Disables 64bit capable Devices to be Decoded in Above 4G Address Space Only if System Supports 64 bit PCI Decoding Enabled Disabled SR IOV Support If system has SR IOV capable PCIe Devices this opti...

Page 155: ...option to change the Common RefCode Settings UPI Configuration Displays and provides option to change the Uncore Settings Memory Configuration Displays and provides option to change the Memory Settin...

Page 156: ...TXT Enable Intel TXT Disabled Enabled Intel Virtualization Technology Intel Virtualization Technology allows a platform to run multiple operating systems and applications in independent partitions No...

Page 157: ...http www tyan com 157 5 3 9 1 1 Per Socket Configuration CPU Socket 0 Configuration CPU Socket 0 Configuration CPU Socket 1 Configuration CPU Socket 1 Configuration...

Page 158: ...om 158 5 3 9 1 1 1 CPU Socket 0 Configuration Core Disable Bitmap Hex 0 Enable all cores FFFFFFFFFF Disable all cores NOTE At least one core per CPU must be enabled Disabling all cores is an invalid c...

Page 159: ...om 159 5 3 9 1 1 2 CPU Socket 1 Configuration Core Disable Bitmap Hex 0 Enable all cores FFFFFFFFFF Disable all cores NOTE At least one core per CPU must be enabled Disabling all cores is an invalid c...

Page 160: ...512M 1G 2G Auto MMIO High Base Select MMIO High Base 56T 40T 32T 24T 16T 4T 3T 2T 1T MMIO High Granularity Size Selects the allocation size used to assign mmioh resources Total mmioh space can be up...

Page 161: ...http www tyan com 161 Numa Enable or Disable Non uniform Memory Access NUMA Disabled Enabled...

Page 162: ...http www tyan com 162 5 3 9 3 UPI Configuration UPI General Configuration Displays and provides option to change the UPI General Settings...

Page 163: ...Link Frequency Select Allows for selecting the UPI Link Frequency 9 6GT s 10 4GT s 11 2GT s Auto Use Per Link Setting Link L0p Enable Enable Set the c_l0p_en Disable Reset it Auto Auto decides based...

Page 164: ...TI Prefetch enable 4 IMC may interleave SNC2 Enable supports 2 clusters SNC and 2 way IMC interleave SNC4 Enable supports 4 clusters SNC and 1 way IMC interleave Enable SNC2 or SNC4 will gray out IMC...

Page 165: ...http www tyan com 165 5 3 9 3 1 1 UPI Status Read only...

Page 166: ...support Auto Sets it to the MRC default setting current default is Enable Enforce POR Disabled Memory Frequency Maximum Memory Frequency Selections in Mhz If Enforce POR is disabled user will be able...

Page 167: ...http www tyan com 167 Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not Enabled Disabled...

Page 168: ...of memory to be mirrored If rank sparing is enabled partial mirroring will not take effect Enabling any type of Mirror Mode will disable XPT Prefetch Disabled Full Mirror Mode Partial Mirror Mode Mir...

Page 169: ...VMD for Volume Management Device Configuration menu PCIe Hot Plug Enable Disable PCIe Hot Plug globally Disabled Enabled PCIe ACPI Hot Plug Enable Disable PCIe ACPI Hot Plug globally or allow per port...

Page 170: ...http www tyan com 170 Skip PCIe retimers detection Skip PCIe retimers detection to speedup the boot Retimers are present only in specific HW configurations Disabled Enable...

Page 171: ...port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 IOU3 IIO PCIe Port 4 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 IOU4 IIO PCIe Port 5 Selects...

Page 172: ...ble is used to disable the port and hide its CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Auto Disabled Enabled Surprise Hot Plug C...

Page 173: ...ntrol LNKCON2 6 for this PCIe port 6 0 dB 3 5 dB PCI E Port MPSS Configure Max Payload Size supported in PCIe Device Capabilities register 128B 256B 512B Auto PCI E ASPM Support This option enables di...

Page 174: ...ifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 IOU3 IIO PCIe Port 4 Selects PCIe port Bifurcation for selected slot s x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 IOU4 IIO PCIe Port 5 Selects PCIe...

Page 175: ...CFG space Auto Disabled Enabled Hot Plug Capable This option specifies if the link is considered Hot Plug capable Auto Disabled Enabled Surprise Hot Plug Capable This option specifies if the link is...

Page 176: ...CI E Port MPSS Configure Max Payload Size supported in PCIe Device Capabilities register 128B 256B 512B Auto PCI E ASPM Support This option enables disables the ASPM L1 support for the downstream devi...

Page 177: ...9 5 3 Intel VT for Directed I O VT d Intel VT for Directed I O VT d Enable Disable Intel Virtualization Technology for Directed I O VT d by reporting the I O device assignment to VMM through DMAR ACP...

Page 178: ...http www tyan com 178 5 3 9 5 4 Intel VMD Technology...

Page 179: ...e VMD in this Stack Disabled Enabled VMD Config for IOU0 Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU1 Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU2 Ena...

Page 180: ...http www tyan com 180 VMD Config for IOU4 Enable Disable VMD in this Stack Disabled Enabled...

Page 181: ...0 Enable Disable VMD Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU1 Enable Disable VMD Enable Disable VMD in this Stack Disabled Enabled VMD Config for IOU2 Enable Disable VMD R...

Page 182: ...ug Capable Enable Disable Hot Plug for PCIe Root Ports Disabled Enabled CfgBar size Setup VMD Config BAR size in bits Min 20 Max 27 ex 20bits 1MB 27bits 128MB 25 CfgBar attribute Set up VMD Config Bar...

Page 183: ...ibute like 64 bit or prefetchable 32 bit non prefetchable 64 bit non prefetchable 64 bit prefetchable VMD for Direct Assign Enable Disable VMD for Direct Assign Disabled Enabled VMD Config for IOU4 En...

Page 184: ...anagement Configuration CPU P State Control P State Control Configuration Sub Menu include Turbo XE and ete Hardware PM State Control Hardware P State setting CPU C State Control CPU C State setting P...

Page 185: ...namic SSTPP Select Disabled Enabled Intel SST PP Intel SST PP Select allows user to choose from up to two additional base frequency conditions Base Config 3 Config 4 Energy Efficient Turbo Energy Effi...

Page 186: ...http www tyan com 186 Perf P Limit Enable Disable Performance P Limit Disabled Enabled...

Page 187: ...Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS guidance Out of Band Mode Hardware autonomously chooses a P state no OS guidan...

Page 188: ...e C State Package C State limit C0 C1 state C2 state C6 non Retention state Auto CPU C6 report Enable Disable CPU C6 ACPI C3 report to OS Disabled Enabled Auto Enhanced Halt State C1E Core C1E auto pr...

Page 189: ...abled PL1 Power Limit PL1 Power Limit in Watts The value may vary from 0 to Fused value If the value is 0 the fused value will be programmed A value greater than fused TDP value will not be programmed...

Page 190: ...ime Window Disabled Enabled PL2 Power Limit PL2 Power Limit in Watts The value may vary from 0 to Fused value If the value is 0 BIOS programs 125 TDP 0 PL2 Time Window PL2 value in seconds The value m...

Page 191: ...http www tyan com 191 5 3 10 Memory Topology Read only...

Page 192: ...1 Server ME Configuration Altitude The altitude of the platform location above the sea level expressed in meters The hex number is decoded as 2 s complement signed integer Provide the 8000h value if t...

Page 193: ...http www tyan com 193 5 3 12 SATA Configuration SATA Configuration SATA devices and settings SSATA Configuration sSATA devices and settings...

Page 194: ...d Configure SATA as Identify the SATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID Support Aggressive Link Power Management Enables Disables SALP Disabled Enabled Port 0 1 2 3 4...

Page 195: ...ormed and only the drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State...

Page 196: ...led Configure sSATA as Identify the sSATA port is connected to Solid State Drive or Hard Disk Drive AHCI RAID Support Aggressive Link Power Management Enables Disables SALP Disabled Enabled Port 0 1 2...

Page 197: ...drives witch have this option enabled will spin up at boot Otherwise all drives spin up at boot Disabled Enabled sSATA Device Type Identify the SATA port is connected to Solid State Drive or Hard dis...

Page 198: ...nfiguration PCH Devices Enable Disable Intel IO Controller Hub devices PCI Express Configuration PCI Express Configuration settings USB Configuration USB Configuration Settings ADR Configuration Autom...

Page 199: ...http www tyan com 199 5 3 13 1 PCH Devices Restore AC Power Loss Select S0 S5 for ACPI state after a G3 Power On Power Off Last State...

Page 200: ...http www tyan com 200 5 3 13 2 PCI Express Configuration PCI Express Root Port 1 20 PCI Express Root Port 1 20 Settings...

Page 201: ...ess Root Port Disabled Enabled ASPM Support Set the ASPM Level Force L0s Force all links to L0s state AUTO BIOS auto configure DISABLE Disables ASPM Disable ASPM ASPM L1 ASPM Auto L1 Substates PCI Exp...

Page 202: ...http www tyan com 202 Max Payload Size PCIE Max Payload Size Selection MPL128B MPL256B...

Page 203: ...203 5 3 13 3 USB Configuration XHCI Idle L1 Enabled XHCI Idle L1 Disabled to workaround USB3 hot plug will fail after 1 hot plug removal Please put the system to G3 for the new settings to take effect...

Page 204: ...Platform POR Enabled Disabled ADR GPIO Select between GPIO_B or GPIO_C GPIO_B GPIO_C Host Partition Reset ADR Enable Enables Disables ADR on Host Partition Reset Platform POR Enabled Disabled Enable...

Page 205: ...http www tyan com 205 ADR timer multiplier Select proper ADR timer multiplier x1 8 24 40 56 64 72 80 88 96 Platform POR x1 x8 x24 x40 x56 x64 x72 x80 x88 x96...

Page 206: ...http www tyan com 206 5 3 14 Miscellaneous Configuration Active Video Select active video type Onboard Device Offboard Device...

Page 207: ...www tyan com 207 5 3 15 Runtime Error Logging System Errors System Error Enable Disable setup options Disabled Enabled Memory Error Enabling Press Enter to view or change the Memory errors enabling op...

Page 208: ...http www tyan com 208 5 3 15 1 Memory Error Enabling Memory Error Enable Disable Memory Error Disabled Enabled Spare Interrupt Spare Interrupt Selection Disabled SMI Error Pin CMCI...

Page 209: ...abled Enabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Disabled Enabled USB Mass Storage Driver Support...

Page 210: ...er up delay in seconds is available when Device power up delay is set to Manual Device power up delay in seconds Delay range is 1 40 seconds in one second increments 5 AMI Virtual CDROM0 1 00 Mass sto...

Page 211: ...www tyan com 211 5 3 17 NVMe Configuration This page shows the Device Name you installed Press Enter to read the device information If no NVME device is installed it shows no NVME device is found Read...

Page 212: ...LAN Enable Disable control function Enabled Disabled Onboard LAN 2 I210 LAN Enable Disable control function Enabled Disabled ICC Clock Spread Spectrum Turn on off Spread Spectrum Setting for IsCLK Ena...

Page 213: ...http www tyan com 213 NMI Button Enable or Disable NMI button Enabled Disabled...

Page 214: ...rface Settings Redfish Enable Disable AMI Redfish Enabled Disabled Authentication mode Select authentication mode Basic Authentication Session Authentication IP Address Enter IP address IP Mask Addres...

Page 215: ...items are available when Network Stack is set to Enabled Ipv4 PXE Support Enable Ipv4 PXE Boot Support If disabled IPV PXE boot option will not be created Disabled Enabled Ipv4 HTTP Support Enable Ipv...

Page 216: ...nable Ipv6 HTTP Boot Support If disabled IPV6 HTTP boot option will not be created Disabled Enabled PXE boot wait time Wait time to press ESC key to abort the PXE boot 0 Media detect count Number of t...

Page 217: ...Speed Control BIOS setting from Manual to Full Speed when installing the Nvidia GeForce Quardro GPU and any VGA card PWM Minimal Duty Cycle PWM Minimal Duty Cycle 60 NOTE This item is available when...

Page 218: ...http www tyan com 218 5 3 21 1 Sensor Data Register Monitoring NOTE SDR can not be modified Read only...

Page 219: ...ADR Enables the detecting and enabling of ADR This is not available if eADR is enabled since eADR requires ADR to be enabled Enabled Disabled Assert ADR on Reset Assert ADR on Reset Enabled Disabled A...

Page 220: ...U Registration Sign up the current CPU This item support INTEL CPU sign the CPU will record current CPU Once BIOS checked different with registered CPU show WARNING message on POST screen Deregistrati...

Page 221: ...3 24 Memory Registration Sign up the current Memory Sign the Memory will record current Memory Once BIOS checked different with registered Memory show WARNING message on POST screen Deregistration Sig...

Page 222: ...http www tyan com 222 5 3 25 T1s Auth Configuration Server CA Configuration Press Enter to configure Server CA Client Cert Configuration Press Enter to configure Client Cert...

Page 223: ...http www tyan com 223 5 3 25 1 Server CA Configuration Enroll Cert Press Enter to enroll cert Delete Cert Press Enter to delete cert...

Page 224: ...nroll Cert Enroll Cert Using File Enroll Cert Using File Cert GUID Input digit character in 11111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Commit Changes and Exit Discard Changes...

Page 225: ...http www tyan com 225 5 3 25 1 2 Delete Cert FE9C6606 8B49 44A3 8B6B DEA3A0E032 GUID for CERT Disabled Enabled...

Page 226: ...low the instructions to initiate the iSCSI function Step 1 Select Advanced CSM Configuration Network UEFI Step 2 Select Advanced Network Stack Configuration Network Stack Enabled Step 3 Save changes a...

Page 227: ...nitiator Only IQN format is accepted Enter iqn xxx xxx ranges from 4 to 223 Add an Attempt Add an Attempt Delete Attempts Delete one or more attempts Change Attempt Order Change the order of Attempts...

Page 228: ...http www tyan com 228 5 3 26 1 1 Add an Attempt NOTE Only LAN1 supports iSCSI function MAC xx xx xx xx xx xx Intel I210 Gigabit Network Connection PFA Bus 2 Dev 0 Func 0...

Page 229: ...tempt 1 Attempt iSCSI Mode Disabled Enabled Enabled for MPIO Disabled Enabled Enabled for MPIO Internet Protocol Initiator IP address is system assigned in IP6 mode In Autoconfigure mode iSCSI driver...

Page 230: ...in dotted decimal notation Initiator Subnet Mask Enter IP address in dotted decimal notation Gateway Enter IP address in dotted decimal notation Target Name The worldwide unique name of the target On...

Page 231: ...PFA Bus 2 Dev 0 Func 0 iSCSI mode Disabled IP version IPv4 Disabled Enabled Attempt 2 MAC xx xx xx xx xx xx PFA Bus 2 Dev 0 Func 0 iSCSI mode Disabled IP version IPv4 Disabled Enabled Commit Changes a...

Page 232: ...t Order Change the order of Attempts using keys Use arrow keys to select the attempt then press to move the attempt up down in the attempt order list Attempt 1 Attempt 2 Commit Changes and Exit Commit...

Page 233: ...http www tyan com 233 5 3 27 VLAN Configuration MAC Address Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Page 234: ...27 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Page 235: ...tp www tyan com 235 5 3 28 MAC Address IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and Exi...

Page 236: ...http www tyan com 236 5 3 29 MAC Address IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Page 237: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address D...

Page 238: ...4 New Gateway addresses Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS addre...

Page 239: ...http www tyan com 239 5 3 30 Intel I210 Gigabit Network Connection NIC Configuration Click to configure the network device port Blink LEDs Blink LEDs for a duration up to 15 seconds 0...

Page 240: ...ocol Auto Negotiated 10 Mbps Half 10Mbps Full 100Mbps Half 100Mbps Full Wake On LAN Enables power on of the system via LAN Note that configuring Wake on LAN in the operating system does not change the...

Page 241: ...http www tyan com 241 5 3 31 VLAN Configuration MAC Address Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Page 242: ...31 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Page 243: ...tp www tyan com 243 5 3 32 MAC Address IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and Exi...

Page 244: ...http www tyan com 244 5 3 33 MAC Address IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Page 245: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address D...

Page 246: ...4 New Gateway addresses Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS addre...

Page 247: ...http www tyan com 247 5 3 34 Intel I210 Gigabit Network Connection NIC Configuration Click to configure the network device port Blink LEDs Blink LEDs for a duration up to 15 seconds 0...

Page 248: ...ocol Auto Negotiated 10 Mbps Half 10Mbps Full 100Mbps Half 100Mbps Full Wake On LAN Enables power on of the system via LAN Note that configuring Wake on LAN in the operating system does not change the...

Page 249: ...http www tyan com 249 5 3 35 VLAN Configuration MAC Address Enter Configuration Menu Press ENTER to enter configuration menu for VLAN configuration...

Page 250: ...35 1 Enter Configuration Menu VLAN ID VLAN ID of new VLAN or existing VLAN valid value is 0 4094 Priority 802 1Q Priority valid value is 0 7 Add VLAN Create a new VLAN or update existing VLAN Remove V...

Page 251: ...tp www tyan com 251 5 3 36 MAC Address IPv4 Network Configuration Configured Indicate whether network address configured successfully or not Disabled Enabled Save Changes and Exit Save Changes and Exi...

Page 252: ...http www tyan com 252 5 3 37 MAC Address IPv6 Network Configuration Enter Configuration Menu Press ENTER to enter configuration menu for IPv6 configuration...

Page 253: ...DAD Transmit Count The number of consecutive Neighbor Solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address D...

Page 254: ...4 New Gateway addresses Gateway IP address can only be configured under manual policy e g 2002 3 Separate the IP address with blank space to configure more than one address New DNS addresses DNS addre...

Page 255: ...page may vary in accordance with the cards you installed Intel PRO 1000 8 5 21 PCI E Provides Health Status for the Drivers Controllers Healthy Intel PRO 1000 8 5 21 PCI E Provides Health Status for t...

Page 256: ...enshot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 6136CF98 Provides Health Status for the Drivers Controllers Healthy Intel I210...

Page 257: ...ot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 61375698 Child 0 Provides Health Status for the Drivers Controllers Healthy Intel I...

Page 258: ...MD Technology 7 5 0 1152 NOTE This is a sample screenshot of the Driver Health The information displayed here may vary in accordance with the card you installed Controller 612FDB18 Child 0 Provides He...

Page 259: ...Policy are available when FRB 2 Timer is set to Enabled FRB 2 Timer timeout Enter value Between 3 to 6 min for FRB 2 Timer Expiration value Not available if FRB 2 Timer is disabled 3 minutes 4 minute...

Page 260: ...mer is set to Enabled OS Wtd Timer timeout Configure the length of the OS Boot Watchdog Timer Not available if OS Boot Watchdog timer is disabled 5 minutes 10 minutes 15 minutes 20 minutes OS Wtd Time...

Page 261: ...ed option will not modify any BMC network parameters during BIOS phase Unspecified Static DynamicBmcDhcp DynamicBmcNonDhcp Management Port 2 Enable Disable BMC Share NIC Enabled Disabled Configure IPV...

Page 262: ...http www tyan com 262 5 4 2 BMC User Settings Add User Press Enter to Add a user Delete User Press Enter to Delete a user Change User Settings Press Enter to change User Settings...

Page 263: ...ord Enter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Channel Number N A 1 8 User Privilege Limit Enter...

Page 264: ...http www tyan com 264 5 4 2 2 Delete User User Name Enter BMC User Name User Password Enter New Password to change Password at least 8 characters...

Page 265: ...ssword at least 8 characters Change User Password Enter New Password to change Password at least 8 characters User Access Enable Disable the BMC User s Access Enabled Disabled Channel No Enter BMC Cha...

Page 266: ...ord window will pop out to ask for confirmation User Password Set user password in the Create New Password window After you key in the password the Confirm New Password window will pop out to ask for...

Page 267: ...t Mode Secure Boot mode selector Standard Custom In Custom mode Secure Boot Variables can be configured without authentication Standard Custom Restore Factory Keys Force System to User Mode Install fa...

Page 268: ...http www tyan com 268 Key Management Enables expert users to modify Secure Boot Policy variables without full authentication...

Page 269: ...ry Keys Force System to User Mode Install factory default Secure Boot key databases Press Yes to proceed No to cancel Reset to Setup Mode Delete all Secure Boot key database from NVRAM Deleting all va...

Page 270: ...SA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI PE C0FF Image SHA256 Key source Factory External Mixed Details Export Update Delete Key Exchange Keys Enroll Factory Defaults or load c...

Page 271: ...oll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER c EFI_CERT_RSA2048 bin d EFI_CERT_SHAXXX 2 Authenticated UEFI Variable 3 EFI...

Page 272: ...onds to wait for setup activation key 65535 0xFFFF means indefinite waiting 1 Bootup NumLock State Select the keyboard NumLock state Off On Quiet Boot Enable or disable Quiet Boot option Enabled Disab...

Page 273: ...ESC If Error Wait for ESC key to be pressed if error occurs Enabled Disabled Boot Option Priorities Boot Option 1 4 Select the system boot order Device Name Disabled Delete Boot Option Remove an EFI b...

Page 274: ...http www tyan com 274 5 6 1 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to delete Device Name...

Page 275: ...it Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving any changes Save Changes Sa...

Page 276: ...Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore the User Defaults to all the setup opt...

Page 277: ...6 1 Flash Utility Every BIOS file is unique for the motherboard it was designed for For Flash Utilities BIOS downloads and information on how to properly use the Flash Utility with your motherboard pl...

Page 278: ...DS execution 0xD0 0xDF DXE errors 0xE0 0xE8 S3 Resume PEI 0xE9 0xEF S3 Resume errors PEI 0xF0 0xF8 Recovery PEI 0xF9 0xFF Recovery errors PEI Standard Checkpoints SEC Phase Status Code Description 0x0...

Page 279: ...ory North Bridge initialization North Bridge module specific 0x19 Pre memory South Bridge initialization is started 0x1A Pre Memory South Bridge initialization South Bridge module specific 0x1B Pre me...

Page 280: ...on codes 0x4F DXE IPL is started PEI Error Codes 0x50 Memory initialization error Invalid memory type or incompatible memory speed 0x51 Memory initialization error SPD reading has failed 0x52 Memory i...

Page 281: ...ation 0x62 Installation of the South Bridge Runtime Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66...

Page 282: ...s 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bus initialization is started 0x93 PCI Bus Hot Plug Controller initialization 0x94 PCI Bus Enumeration 0x95...

Page 283: ...ation codes DXE Error Codes 0xD0 CPU initialization error 0xD1 North Bridge initialization error 0xD2 South Bridge initialization error 0xD3 Some of the Architectural Protocols are not available 0xD4...

Page 284: ...aking up from the S1 sleep state 0x20 System is waking up from the S2 sleep state 0x30 System is waking up from the S3 sleep state 0x40 System is waking up from the S4 sleep state 0xAC System has tran...

Page 285: ...nt shall Tyan be liable for direct indirect incidental special or consequential damages arising from the BIOS update or recovery The BIOS Recovery file is named xxxx cap where the xxxx portion is the...

Page 286: ...t the server during the BIOS recovery process This can damage the BIOS recovery bootloader and prevent it from loading a subsequent time 7 Wait for the BIOS recovery procedure to complete Completion i...

Page 287: ...the IO Plate for the dual port LAN card M7062 I599 2T 1 Use a screwdriver to break the semi shearing for the OCP card slot Discharge the metal slug 2 Take out the IO plate for LAN card Use a screwdri...

Page 288: ...http www tyan com 288 3 Insert the IO Plate to the OCP card LAN port Screw the IO Plate to the chassis 4 Insert the LAN card into the OCP slot and secure the LAN card to the chassis with four screws...

Page 289: ...Fan4 FAN4 Fan5 FAN5 Fan6 FAN6 2 FP Control Cable Front Panel Board FPB to S7126 MB for all Series M1724G68 FPB Connect to S7126GM2NRE FP CTRL J1 FPIO_1 3 NVME SIGNAL Cable BP to S7126 MB for B7126G68V...

Page 290: ...02G68 BP12 4 bottom 2 4P Micro Fit PWR PW4 J30 B4P PWR PW3 PW2 M1631G68 D 85A PDB Connect to M1312G68 BP6E 4X top 2 4P to 1 8P PWR PW6 J1 Power Board PDB to BP for B7126G68AV10E2HR M1631G68 D 85A PDB...

Page 291: ...E1 SLIMSAS2 4i OCulink to Slim SAS 4i P N 422T60300004 NVME2 SLIMSAS3 4i OCulink to Slim SAS 4i P N 422T60300005 NVME3 SLIMSAS4 BP to S7126 MB for B7126G68AV10E2HR M1303G68A BP1 2E 12X Connect to S712...

Page 292: ...http www tyan com 292 NOTE...

Page 293: ...rd A table of BIOS Temp sensor name explanation is also included for readers reference Figure 1 Sensor Location NOTE The red spot indicates the sensor Fan and Temp Sensor Location 1 Fan Sensor It is l...

Page 294: ...http www tyan com 294 BIOS Temp Sensor Name Explanation...

Page 295: ...http www tyan com 295...

Page 296: ...rature of CPU0 DIMM Channel E P0_MC2_DIM_CH_F Temperature of CPU0 DIMM Channel F P0_MC3_DIM_CH_G Temperature of CPU0 DIMM Channel G P0_MC3_DIM_CH_H Temperature of CPU0 DIMM Channel H P1_MC0_DIM_CH_A T...

Page 297: ...eed of SYS_FAN_10 SYS_FAN_11 Fan Speed of SYS_FAN_11 SYS_FAN_12 Fan Speed of SYS_FAN_12 PSU0_STATUS Current status of PSU0 PSU0_Temp Temperature of PSU0 PSU0_FAN Fan Speed of PSU0 PSU1_STATUS Current...

Page 298: ...http www tyan com 298 NOTE...

Page 299: ...0250 346T60300011 Airduct for CPU PCBA FRU RC 1240 411T60300092 M7126 L16 1F riser card FRU RC 1250 411T60300096 M7126 R16 1F riser card Slide Rail Kit FRU AS 0210 452T60300002 Toolless rail kit w o...

Page 300: ...B7126G68V4E4HR FRU CS 1780 422T60300010 500 mm SlimSAS 8i 74P to 2 SlimSAS 4i 38P cable for B7126G68AV10E2HR FRU CS 0510 422T53400005 700 mm SHORT MINI SAS HD 36P to SHORT MINI SAS HD 36P cable for B...

Page 301: ...expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports...

Page 302: ...oper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manuf...

Reviews: