2. Free the power from the power socket.
3. Replace a new power supply and reinsert it into the power socket following
the above steps in reverse.
3.9 Replacing the Power Distribution Board
Please unplug the power cord before you follow these instructions to replace the
Tiger PDB Redundant Control Board
Power Distribution Board.
1.
Disconnect all the power cables.