Twyford X52 Series Instruction Booklet Download Page 10

10

Deck Mounted Bath Filler and Bath Shower Mixer

Identify all components are present prior to starting 
the installation.

1. Fit the mixer body to the bath ensuring that the 

gasket is between the body and bath.

2. Secure the mixer to the bath using the washers 

and plastic backnuts below the bath.
Tighten the backnuts onto the threaded tails.
A suitable spanner may be required to fully 
tighten the backnut.

3. Connect the hot and cold water supplies to the 

threaded tails using a ¾” BSP connector or 
preferably an isolation valve for future servicing 
convenience (not supplied). 

4. Bath Shower Mixer only

-

 

fit the shower hose to 

the hose outlet using the small sealing washer, 
and the handset to the hose using the small 
washer. 

5. Fit the wall bracket (not shown) to the wall using

the fixings supplied, ensuring the handset and 
hose reaches it.

6. To switch from bath to shower mode, pull the 

diverter knob up, to revert back to bath filling 
mode push the diverter knob back down.

7. Turn on water supplies and turn both handles int o

the on position, letting the water flow for a few 
minutes and purging all air.

8. Check all joints and connections for any leaks. 

Installation continued

(X525255CP, X525265CP)

Prior the drilling into walls, check there no 

hidden electrical wires, cables or water supply pipes 
with the aid of an electronic detector.       

If you use power tools do not forget to:

• Wear eye protection
• Unplug equipment after use

Drawings for illustration purposes only

Washer

Backnut

Shower hose screws in
from underneath.

Gasket

Diverter knob

Summary of Contents for X52 Series

Page 1: ...Please keep these instructions for future reference X52 Tap Range This instruction booklet covers X525126CP X525135CP X525925CP X525255CP X525265CP...

Page 2: ...correctly These tting instructions have been created to give you all of the information you need and if you need any further help please do not hesitate to give us a call on 0844 412 5951 Important Sa...

Page 3: ...pment after use This product must not be modi ed from the original design as this will invalidate the guarantee These ttings need to be installed in accordance with and meet the requirements of the Wa...

Page 4: ...40 4 66 5 96 6 02 4 67 6 32 6 55 5 31 6 81 6 75 6 80 3 40 3 46 3 82 4 91 4 76 5 22 6 30 6 22 6 70 6 72 6 72 6 82 6 30 6 30 6 62 6 39 6 32 6 44 6 27 6 12 6 31 6 24 6 31 6 29 FlowRate Litre sperminute 0...

Page 5: ...8 46 5 98 5 88 7 26 8 30 8 04 9 99 11 52 11 40 14 04 14 20 13 88 17 26 16 32 16 08 19 57 18 26 17 88 22 16 19 88 19 57 24 38 20 65 20 32 25 40 05 Dimensions Deck Mounted Bidet Mixer Clicker Waste X52...

Page 6: ...MIX HOT COLD MIX HOT COLD MIX 3 34 3 32 3 08 4 41 4 37 4 17 5 16 5 18 5 01 4 82 4 87 4 66 5 07 5 08 4 96 5 12 5 15 5 03 5 10 5 08 4 96 5 12 5 08 4 99 6 62 6 61 5 45 9 24 9 11 7 69 13 01 12 68 10 65 1...

Page 7: ...OLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX FlowRate Litre sperminute 0 5 Bar 1 0 Bar 2 0 Bar 3 0 Bar 4 0 Bar 5 0 Bar 6 0 Bar 8 0 Bar 2 Back Nuts...

Page 8: ...ack Nuts 102 5 81 111 54 231 154 180 80 3 4 BSP 1 2 BSP HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX HOT COLD MIX FlowRate Litre sperminute 0 5 Bar 1 0 Ba...

Page 9: ...inst the C shaped metal washer The xing nuts can be tightened with a suitable spanner 6 Connect the exi tails to the hot and cold water supplies 7 Turn on water supplies lift the mixer handle upwards...

Page 10: ...asher and the handset to the hose using the small washer 5 Fit the wall bracket not shown to the wall using the xings supplied ensuring the handset and hose reaches it 6 To switch from bath to shower...

Page 11: ...Bidet Mixer the ow restrictor is incorporated into the ow Straightener in the spout Removal Using a suitable spanner carefully unscrew the ow straightener from the tap spout Re tting Make sure the rub...

Page 12: ...eak the following should be carried out 1 Isolate both hot and cold water supplies to the tap by either a Turning the water supply off at the mains stopcock b Turning off the isolation valves to the t...

Page 13: ...ed by capillary action and residual water in the spout being siphoned out This should only last for a couple of seconds Constant dripping leaking when the tap is not in use Cartridge Valve not fully s...

Page 14: ...shers incorrect installation repair using non Twyford parts accidental or wilful misuse corrosion and the use of inappropriate cleaning products system debris including the build up of limescale which...

Page 15: ...15 Notes...

Page 16: ...vers X525126CP X525135CP X525925CP X525255CP X525256CP Twyford Lawton Road Alsager Stoke On Trent ST7 2DF UK UK Technical Helpline Telephone 0844 412 5951 Or 01270 871480 Email customerservice twyford...