Twinno T4058 Operating Manual Download Page 3

Features

Industrial online dissolved ozone monitor is an online water quality monitor with 
microprocessor. The instrument is widely used in drinking water treatment plant, drinking 
water distribution network, swimming pool, water quality treatment project, sewage 
treatment, water quality disinfection (ozone generator matching) and other industrial 
processes.It continuously monitor and control the ozone value in water solution.

Color LCD display

Intelligent menu operation

Multiple automatic calibration function

Manual and automatic temperature compensation

Two relay control switches

High & low alarm and hysteresis control

4-20mA & RS485,Multiple output modes

Multi parameter display simultaneously shows –Dissloved Ozone, Temp, current,etc.

Password protection function to prevent misoperation by non-staff.

Preface

Thank you for your support. Please read this manual carefully before use.The correct use 
will maximize the performance and advantages of the product, and bring you a good 
experience.
When receiving the instrument, please open the package carefully, check whether the 
instrument and accessories are damaged by transportation and whether the accessories 
are complete. If any abnormalities are found, please contact our after-sales service 
department or regional customer service center, and keep the package for return 
processing.

This instrument is an analytical measurement and control instrument with highly 
precision.Only skilled,trained or authorized person should carry out installation, setup and 
operation of the instrument.Ensure that the power cable is physically separated from the 
power supply when connection or repair.Once the safety problem occurs, make sure that 
the power to the instrument is off and disconnected.
For example, it may insecurity when the following situations occur:
1) Apparent damage to the analyzer
2) The analyzer does not work properly or provides specified measurements.
3)The analyzer has been stored for a long time in an environment where the temperature
exceeds 70 °C.

The analyzer must be installed by professionals in accordance with relevant local 
specifications, and instructions are included in the operation manual.
Comply with the technical specifications and input requirements of the analyzer.

1

We Instruments warrants this product to be free from significant deviations in material and  
workmanship for a period of one year from the date of purchase. If repair is necessary 
and has not been the result of abuse or misuse within the warranty period, please return 
to We Instruments and amendment will be made without any charge. We Instruments 
Customer Service Center will determine if product problem is due to deviations or 
customer abuse. Out of warranty products will be repaired on a charge basis.

Authorization must be obtained from We Instruments Customer Service Center to issue a  
RIR number before returning items for any reason. When applying for authorization, please  
nclude date requiring the reason of return. Instruments must be carefully packed to 
prevent  damage in shipment and insured against possible damage or loss. We 
Instruments will not  be responsible for any damage resulting from careless or insufficient 
packing.
Warning: Damage as a result of inadequate packaging is the User / distributor’s 
responsibility.
Please follow the guidelines below before transporting.

Use the original packaging materialif possible, when transporting back the unit for repair. 
Otherwise wrap it with bubble pack and use a corrugated box for better protection. 
Include a brief description of any faults suspected for the convenience of Customer 
Service Center, if possible.If there are any questions, feel free to contact our Customer 
Service Center or distributors.

Warranty 

22

Summary of Contents for T4058

Page 1: ...021 61621099 Web www twinno net Add Building 6 No 166 Mindong Road Pudong New District Shanghai China Post code 201209 T4058 Online Dissloved Ozone Analyzer Operating Manual Shanghai Chunye Instrument Technology Co Ltd Operating Manual 8 025mg L T4058 Dissloved Ozone ...

Page 2: ...This instrument is not suitable for use in harsh environment high temperature low temperature or strong magnetic field interference which may lead to instrument damage ӹ If there is any problem with the instrument please contact the dealer or the company Do not disassemble the instrument by yourself If disassembled the company will no longer be responsible for the warranty Notes 23 Table of Conten...

Page 3: ...curity when the following situations occur 1 Apparent damage to the analyzer 2 The analyzer does not work properly or provides specified measurements 3 The analyzer has been stored for a long time in an environment where the temperature exceeds 70 C The analyzer must be installed by professionals in accordance with relevant local specifications and instructions are included in the operation manual...

Page 4: ...concentration to observe whether the meter works normally If the meter works normally the concentration of the measured medium may exceed the range 6 Measurements display results fluctuate greatly Possible causes Sensor wiring error or low display rate setting Solutions Check wiring or increase display rate appropriately FAQ 21 Technical Specifications Measurement range Measurement theory Resoluti...

Page 5: ... 5 mm 3 92 5 mm 10 mm 120 mm Installation of back cover with waterproofing seal 98 mm 98 mm MENU ESC Package Set Product Description 1 T4058 Online Dissloved Ozone Analyzer 2 Instrument Installation Accessories 3 Operating Manual 4 Qualification Certificate Quantity 1 1 1 1 Note Please check the complete set of instruments before use The company s other series of analytical instruments please logi...

Page 6: ...he instrument may be damaged or its service life may be reduced 3 When cleaning the plastic shell of the instrument please use a soft cloth and a soft cleaner to clean the shell Be careful not to let moisture enter the inside of the instrument 4 Check whether display data of the instrument is normal or not 5 Check whether the wiring on the terminal of the instrument is firm Pay attention to discon...

Page 7: ...e Pow ACL 85 265V Pow AC N Pow PE 18 Read instruction mode The communication protocol adopts MODBUS RTU protocol The content and address of the communication can be changed according to the needs of customers The default configuration is network address 01 baud rate 9600 even check one stop bit users can set their own changes Function code 0x04 This function enables the host to obtain real time me...

Page 8: ...lbyte0 byte3 realbyte1 byte2 realbyte2 byte1 realbyte3 byte0 if realbyte0 0x80 0 S 0 positive number else S 1 negative number E realbyte0 1 realbyte1 0x80 7 127 M realbyte1 0x7f 16 realbyte2 8 realbyte3 D pow 1 S 1 0 M pow 2 23 pow 2 E return D Function description parameters byte0 byte1 byte2 byte3 represent 4 bytes of binary floating point number The decimal number converted from the return valu...

Page 9: ... 0001101 B 24 So the exponential part is 4 plus 127 it becomes 131 and its binary representation is 10000011B Step 3 Calculate the tail number After removing 1 before the decimal point of 1 0001101B the final number is 0001101B because before the decimal point must be 1 so IEEE stipulates that only the decimal point behind can be recorded For the important explanation of 23 bit mantissa the first ...

Page 10: ...put register number high bytes Input register number low bytes Hexadecimal 0x10 0x00 0x01 0x00 0x02 Function code Start Address Register number 1 byte 2 byte 2 byte 0x10 0x0000 0xffff 1 123 0x7B Figure 13 Examples of writing multiple register request and response frames 8 Menu structure If the monitor prompts you to enter the calibration security password press the key or Ӝ key to set the calibrat...

Page 11: ...unction code is used to read the continuous block content of the holding register of the remote device Request the PDU to specify the start register address and the number of registers Address registers from zero Therefore the addressing register 1 16 is 0 15 The register data in the response information is packaged in two bytes per register For each register the first byte contains high bits and ...

Page 12: ...s function is used to calibrate the five calibration points of the sensor It has been calibrated before delivery and users can use it directly If calibration is required prepare 5 suitable standard liquids with known range press the MENU key to enter the setting mode and select the calibration point Modify or enter the corresponding calibration value After setting the calibration value press ENT k...

Page 13: ...document Binary display suffix B for example 10001B decimal display without any prefix or suffix for example 256 Hexadecimal display prefix 0x for example 0x2A ASCII character or ASCII string display for example YL0114010022 Command Structure The MODBUS application protocol defines the Simple Protocol Data Unit PDU which is independent of the underlying communication layer Figure 1 MODBUS Protocol...

Reviews: