MANTEL  LOCATION

When choosing a location for your new fireplace,

 ensure that the general instructions are followed. 

Also, for best effect, install the fireplace out of 

direct sunlight.

                   

                        Cold climate installation recommendation: 

                        when installing this unit against a 

                        non-insulated exterior wall or chase, it is

                        mandatory that the outer walls be insulated

                        to conform to applicable insulation codes.

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt, 60 Hz circuit with a 

properly grounded outlet is required. Preferably, the

fireplace will be on a dedicated circuit as other 

appliances on the same circuit may cause the circuit

breaker to trip or the fuse to blow when the heater is

in operation. The unit comes standard with 6 feet 

(1.8 m) three wire cord, exiting from the rear of the

fireplace. Plan the installation to avoid the use of 

an extension cord. If an extension cord must be 

used, it must be a minimum 14 AWG ; three wires

with grounding type plug connector and rated 

not less than 1875 Watts. The cord shall not be

more than 20 feet (6 m) in length.

ELECTRICAL SPECIFICATIONS

Voltage:         120VAC, 60Hz

Amps:            11.7 Amps

Watts:            1400 Watts

CLEARANCE TO COMBUSTIBLES

Keep electrical cords, drapery, furniture and other 

combustibles at least 3 feet (0.9 m) from the front of the 

heater and away from the sides.

CLEANING TRIM

Clean the metal trim using a soft cloth, slightly 

dampened with citrus oil based product and buff with 

a clean soft cloth. DO NOT use brass polish or 

household cleaners as these products will damage 

the metal trim. Citrus oil based products can be 

obtained at supermarkets or hardware stores.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and 

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended. 

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or 

rewiring of this unit should be carried out by a licensed electrician in accordance with 

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color 

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

 regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a 

qualified service technician to inspect the fireplace and replace any part of the electrical system.

Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk

 of fire, electrical shock or personal injury.

MAINTENANCE

The motors used on the fan and the flame generator assembly are pre-lubricated for extended bearing life and 

require no further lubrication. However, periodic cleaning/vacuuming of the fan/heater unit is recommended. 

Make sure the unit is turned OFF and unplugged whenever you are cleaning the heater or fireplace.

WARNING: Make sure the power is turned off before proceeding. Any electrical repairs or 

rewiring of this unit should be carried out by a licensed electrician in accordance with 

national and local codes.

If repairing or replacing any electrical component or wiring, the original wire routing, color 

coding and securing locations must be followed.

WARNING: Electrical outlet wiring must comply with local building codes and other applicable

 regulations to reduce the risk of fire, electrical shock and injury to persons.

WARNING: Do not use this fireplace if any part of it has been under water. Immediately call a 

qualified service technician to inspect the fireplace and replace any part of the electrical system.

Warning: Disconnect power before attempting any maintenance or cleaning to reduce the risk

 of fire, electrical shock or personal injury.

TROUBLE SHOOTING GUIDE

Warning: During any service of this appliance, the power to the unit must be turned off. 

First turn the main power switch to the “OFF” position. Then remove the electrical plug from 

the wall outlet.

Summary of Contents for 18EF020GAA

Page 1: ...L nea para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU QUESTIONS...

Page 2: ...ALSO Requires Wood Fireplace Mantel V E N T F R E E F I R E P L A C E W I T H H E A T E R Thank you and congratulations on your purchase of a Twin Star International Inc Twin Star fireplace Please re...

Page 3: ...current CSA C22 1 Canadian Electrical Code or for U S A installations follow local codes and the National Electrical Code ANSI NFPA NO 70 17 There is a thermostat limiter inside the heater When the in...

Page 4: ...de it into the opening in the mantel until the flange is flush against the inside of the mantel Make sure insert is centered left and right in the opening Be careful when placing insert and adjusting...

Page 5: ...g Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance with national and local codes If repairing or replacing any electrical component or wiri...

Page 6: ...d clockwise the higher the set point temperature will be Turning the knob counter clock wise will lower the set temperature Use this function to help regulate the ambient temperature HEATER 23 28 33EF...

Page 7: ...e of batteries in re except under conditions of controlled incineration Failure to observe this precaution may result in an explosion NOTE This equipment has been tested and found to comply with the l...

Page 8: ...rate as normal TROUBLE SHOOTING GUIDE SOLUTION PROBLEM 1 No power main switches do not light up 2 Main power switch light up but no flame effect 3 Down lights do not light up 4 Have flame effect but h...

Page 9: ...eplacement or otherwise of same will not be covered by this warranty nor shall the Company assume responsibility for same 6 The owner user assumes all other risks if any including the risk of any dire...

Page 10: ...USSI Manteau en bois pour foyer F O Y E R L E C T R I Q U E N O N R A C C O R D AV E C C H A U F F A G E Nousvousremercionsetvousf licitonsd avoirachet unfoyerdemarqueTwin Star International Inc Twin...

Page 11: ...irer la fiche de la prise de courant 15 Brancher uniquement dans une prise de courant convenable ment mise la terre 16 Une fois install ce foyer doit tre mis la terre conform ment aux codes locaux ou...

Page 12: ...t bien centr dans l ouverture Faites attention lorsque vous placez et ajustez le foyer encastrable car le bas de ce manteau Utilisez les vis fournies ainsi qu un tournevis cruciforme pour remettre les...

Page 13: ...au moins 1 875 W avec trois fils conducteurs et une fiche de mise la terre Par ailleurs elle ne doit pas d passer 6 m 20 pi de long Tension 120 V c a 60 Hz Amp rage 11 7 A Watts 1 400 W ENTRETIEN Les...

Page 14: ...lisateur appuie sur le bouton Flamme l intensit de la flamme diminue Six niveaux d intensit peuvent tre s lectionn s de mani re cyclique y compris la mise l arr t CLAIRAGE DIRIG VERS LE BAS 28 33EF020...

Page 15: ...stallation r sidentielle Cet quipement g n re et utilise de l nergie de fr quence radio et risque s il n est pas install et utilis correctement de provoquer des interf rences de communications radioph...

Page 16: ...IDE 1 Aucune alimentation les interrupteurs principaux ne s allument pas 2 L interrupteur d alimentation principal est allum mais aucun effet de flammes ne se produit 3 Les lumi res clairant vers le b...

Page 17: ...oi 7 Toutes les autres garanties expresses ou implic ites l gard de ce produit de ses composants et accessoires ou de toute obligation responsabilit de la part de la soci t sont express ment exclues p...

Page 18: ...L nea para llamadas en ingl s 866 661 1218 L nea para llamadas en espa ol 866 661 1218 L nea para llamadas en franc s 866 374 9203 STOP STOP PARE PARE ATTENTION SI VOUS AVEZ DES PROBL MES OU QUESTIONS...

Reviews: