the heater will not light after 3 attempts, shutoff the heater, shut-off the heater’s
manual gas inlet valve and call your qualified service agency
B.
USING THE GAS HEATER:
1) Always test the pilot burner ignition as per Step 4 above to insure that the gas valve is
working properly.
2) Turn the main gas supply valve to the OPEN position.
3) Push the “HI” button, then push the “ON” button, you will hear clicking sounds and will see
sparks to the igniter pilot. (Always start with HI setting during initial start-up
4) Once the pilot is lit, the pilot will ignite the infrared burner within 4 seconds. During
ignition a smooth flame will roll down the length of the infrared burner. Flame should stabilize
on the ceramic surface. Within 60 seconds the burner will start to glow bright and radiates heat
CAUTION: The ceramics portion of the infrared burner should glow bright within 60
seconds and may be difficult to see in bright sunlight.
WARNING:
Never attempt to manually light the burner with a match or other source of
flame. Twin Eagles heater utilizes an automatic lighting ignition.
5). HI – LOW SETTING
a)
Push the
“HI”
button and the heater will adjust the gas flow to 37,000 BTU/Hr.
b)
Push the
“LO”
button and the heater will adjust the gas flow to 25,000 BTU/Hr.
6.
SHUTTING DOWN THE HEATER
Push “OFF” on the remote control and verify that the pilot burner and the pilot have turned off.
Should you need to shut down your heater for service or maintenance, the main gas valve next to
the heater should also be turned “OFF”.
16