8.
The gas inlet of the heater is located on the left side of the unit by design.
GAS INLET
The heater is NOT to be mounted to where the gas inlet is on the right side as it may cause
damage to the heater and doing so will void the product warranty.
9.
The heater may be mounted at a 0 degree angle or at a maximum of a 30 degree angle in
reference to the floor. The heater must always be horizontal to the floor.
MOUNTING
o
WARNING: If the heater is mounted at greater than a 30 degree angle will cause
improper flue exhaust of combustion gases which may result in damage to the front
grille.
NOTE:
Use only the mounting brackets provided by the manufacturer. Heater must be leveled
only on a
Horizontal Axis
Clearance around the heater must be maintained for prevent fire hazard and to allow proper
ventilation of the heater. Heater must be in a location that allows uniform air pressure around
the entire heater.
but can be angled to a maximum of 30 degrees in reference to the
floor.
DO NOT
mount the heater on a vertical axis. Such installation is considered unsafe and
improper and will automatically
VOID
the product’s warranty.
10
Angle Mounted Horizontal Mounted
Heater must be installed such that combustion
exit through top vents.
INCORRECT INSTALLATION. GAS IN FROM THE RIGHT SIDE
CORRECT INSTALLATION. GAS IN FROM THE LEFT SIDE
Incorrect Mounting
Radiant Heat
Vent
Vent
Combustion gases exit
through the front grille.