background image

10 

 

OPERATING INSTRUCTIONS 

INITIAL START UP: 

1.

 

Before you start your heater examine the heater installation to determine that: 

 

Areas immediately around heater including the air inlet and flue areas are free from obstructions. 

 

Physical support of the heater is safe, secure, adequate and sound. 

 

There is no obvious deterioration of the heater, gas inlet hose and AC adapter if used. 

2.

 

REMOTE CONTROL SYNCRONIZATION & START-UP TEST: 

 

The remote control leaves the factory already synchronized for each heater.  To verify that, with the 
heater’s gas inlet valve in the CLOSED position, verify that the remote control system is working 
properly. 

 

Push the “ON” button on the remote control.  You will hear a continuous spark sound at the pilot.  If 
there are no sparks, replace the AA batteries with new ones.  If with the new batteries there are still 
no sparks, synchronization is needed.  For synchronization perform the following steps. 

 

Single heater application 

a)

 

Push-and-hold the “LEARN” button on the module for 2 seconds 
until it “beeps”. 

NOTE:

 Holding for 10 seconds will clear the 

module. 

b)

 

Push-and-hold the ON button on the remote and the “beep” sound 
will confirm synchronization. 

NOTE:

 Holding for 10 seconds will 

clear the module. 

 

Multiple heater application 

a)

 

Push-and-hold the “LEARN” button on the module for 2 seconds until it “beeps” and then remove a 
battery.  Repeat same step for all heaters.  

b)

 

Install the battery only to one heater. 

c)

 

Push-and-hold the “LEARN” button until it “beeps” once and then push-and-hold the ON button on 
a remote control and the next “beep” sound will confirm synchronization.   

 

NOTE

: One remote control per heater. 

d)

 

Remove a battery to that same heater. 

e)

 

Repeat steps b, c, d and e for the rest of the heaters and its individual remote controls. 

f)

 

Once the synchronization is completed for all heaters place the battery back on all heaters. 

 

3.

 

Check for gas leaks using soapy water at all gas connections and joint unions.  NEVER use a flame to 
check for leaks. (Pg 3) 

4.

 

Pilot Burner Ignition Test 
a)

 

Turn ON the gas supply to the heater. 

b)

 

Please check the environment of the gas valve for a smell of gas.  If for any reason you smell or 
think you smell gas, see the warning in the box below 

 
 
 
 
 
 
 
 

WHAT TO DO IF YOU SMELL GAS: 

 

Do not try to light any appliance. 

 

Do not touch any electric switch; do not use any phone in your building. 

 

Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s 
instructions. 

 

If you cannot reach your gas supplier, call the fire department. 

MODULE 

“LEARN” 

Summary of Contents for TEGH48-B

Page 1: ...P N 24254B 12 17 OUTDOOR GAS INFRARED PATIO HEATER INSTALLATION USE AND CARE MANUAL MODEL TEGH48 B ...

Page 2: ...n Thank you and welcome TWIN EAGLES _____________________________________________________________________________ FOR YOUR RECORDS Please record the following information and refer to them when contacting the company or an authorized service agent The model number and serial number are found on the nameplate located on the upper left corner of the back cover Model ________________________________ ...

Page 3: ... n est pas raccordée en vue de son utilisation ne doit pas être entreposée dans le voisinage de cet appareil ou de tout autre appareil THIS APPLIANCE IS FOR OUTDOOR USE ONLY If stored indoors detach and leave L P cylinder outdoors CE APPARIEL EST POUR UTILISATION À L EXTÉRIEUR SEULEMENT Si l appareil est entreposé à l interieur enlever les bouteilles et les laisser à l extérieur B E F O R E L I G ...

Page 4: ...REQUIREMENTS LEAK TEST SELECTING MOUNTING LOCATION MOUNTING CLEARANCES ELECTRICAL INSTRUCTIONS OPERATING INSTRUCTIONS PREVENTIVE MAINTENANCE TROUBLESHOOTING GUIDE EXPLODED VIEW REPLACEMENT PARTS LIST LIMITED PRODUCT WARRANTY WARRANTY REGISTRATION CARD 1 2 3 4 7 9 10 12 13 14 15 16 ...

Page 5: ...e Safety Grille that provides shielding from wind Wind proof up to 15 MPH Great option for patios with limited floor space of high traffic areas NG Natural Gas or LP Liquid Petroleum Gas or Propane Gas conversion kits available Optional 120V AC adapter usage is optional o Comes standard with Stainless Steel 16 gauge mounting brackets Flexible gas hose approved for NG or LP installation Wall mounte...

Page 6: ...ory Gas Inlet Pressure Nat Gas Propane Maximum Pressure 10 W C 13 W C Minimum Pressure 6 W C 11 W C Manifold Pressure 5 W C 10 W C a A minimum pipe size of is required for inlet piping A leaver handled shut off gas valve should be installed within 6 feet of the appliance for servicing the unit b Check with local and state plumbing and heating codes regarding sizing of gas lines c All gas connectio...

Page 7: ...ts and wear that may affect the safety before each use Only the factory supplied hose and regulator must be used Use only replacement regulator and hose assemblies specified by Twin Eagles If you are using a propane tank check to ensure that there are no holes dents rusted weak spots cracks or other damage on the propane tank If any damage is detected the tank should be replaced immediately LEAK T...

Page 8: ...d approved for outdoor installation and has passed basic wind and rain tests However do not expose the heater under extremely harsh weather conditions and very windy areas 4 FIRE SPRINKLERS a Fire Sprinklers must be located at an appropriate distance from each heater to avoid accidental activation of the sprinkler Ethylene glycol propylene glycol antifreeze solutions or any other potentially flamm...

Page 9: ...eatest heat loss such as the open side of a semi protected patio area MOUNTING BRACKET ASSEMBLY Angle Mounting the heater may be angle mounted to a maximum of 30 to accommodate mounting the heater around edges of the patio or under eaves NOTE Use only the mounting brackets provided by the manufacturer Heater must be leveled only on a Horizontal Axis but can be angled to a maximum of 30 degrees in ...

Page 10: ...t of combustion gases which may result in damage to the front grille NOTE Use only the mounting brackets provided by the manufacturer Heater must be leveled only on a Horizontal Axis but can be angled to a maximum of 30 degrees in reference to the floor DO NOT mount the heater on a vertical axis Such installation is considered unsafe and improper and will automatically VOID the product s warranty ...

Page 11: ...earance of 24 inches above the heater must be maintained to plastics vinyl or any other materials that may be adversely affected by radiant or convection heat WARNING The clearances shown below are applicable to vehicles parked below or in front of the heater s They are also applicable to retractable awnings umbrellas pergolas etc whether the heater is ON or OFF Do not place any objects whether co...

Page 12: ...the flue outlet of the heater The heater must be installed in a location so that it is readily accessible for servicing and have no restriction of airflow for combustion air and exhaust flue IMPORTANT ALL AREAS AROUND THE HEATER MUST BE CLEARED OF ANY COMBUSTIBLE MATERIALS ...

Page 13: ... for a whole season To install the AC Adaptor An AC DC volt adapter can be used in which case the batteries will become a back up voltage supply The adapter must NEVER be located inside the heater control compartment If adapter is used provide a 120 volt outlet near the end of the heater but not directly above the heater a Run the power lead connectors of the AC adapter through the small hole next...

Page 14: ...nchronization NOTE Holding for 10 seconds will clear the module Multiple heater application a Push and hold the LEARN button on the module for 2 seconds until it beeps and then remove a battery Repeat same step for all heaters b Install the battery only to one heater c Push and hold the LEARN button until it beeps once and then push and hold the ON button on a remote control and the next beep soun...

Page 15: ...ON button again to light the pilot If the heater will not light after 3 attempts shutoff the heater shut off the heater s manual gas inlet valve and call your qualified service agency USING THE GAS HEATER a Always test the pilot burner ignition as per Step 4 above to ensure that the gas valve is working properly b Turn the main gas supply valve to the OPEN position c Push the HI button then push t...

Page 16: ... corrosive environment that will cause the corrosions resistant type 304 stainless steel to develop surface oxidation corrosions or rust Certain areas may discolor overtime This is a normal discoloration caused by the intense heat given off by the burners TWIN EAGLES products have been tested in saline solutions highly chlorinated solutions and have been tested against exposure to highly acidic fo...

Page 17: ...me inconsistently Do not operate equipment until wind dies down or heater is relocated to less windy condition 2 Pilot flame is too small for flame sensing Increase pilot flame such that flame surrounds the pilot sensor rod 3 Heater is installed reversed such that the pilot sensor is below the pilot flame instead of above or even to the pilot flame Correct installation such that the gas inlet is o...

Page 18: ...14 EXPLODED VIEW ...

Page 19: ...NG 1 14 S12407 Flex Tubing 1 15 S16240 Orifice Elbow 2 16 S21959 Baffle Venturi 1 17 S15325 Gas Hose 1 18 S21964 Cover Module 1 19 S21944 Bracket Control Module 1 20 S16171 Control Module 1 21 S16175 Remote Control Black 1 22 S16174 AC Adapter Optional 1 23 S12654 Coupling 3 8 M Flare x 3 8 MPT 1 24 S15113 Valve Dual Stage 1 25 S15114 Rate Screw Orifice LP 1 26 S15115 Rate Screw Orifice NG 1 27 S2...

Page 20: ...excludes discoloration surface scratches weather and atmospheric related staining and minor surface rust and oxidation which are normal conditions and are to be expected with any outdoor product This warranty does not apply to damages resulting from negligence alteration misuse abuse accident natural disaster loss of electrical power to the product for any reason improper installation or improper ...

Page 21: ...lesgrills com Please provide Model number Serial Number Date of Purchase A description of the problem WARRANTY REGISTRATION Customer Name Model Address Serial City State Date Purchased Zip Dealer s Name Phone Dealer s Address e mail THIS WARRANTY REGISTRATION CARD MUST BE RETURNED WITHIN THIRTY DAYS OF PURCHASED TO PROPERLY ACTIVATE YOUR WARRANTY THIS INFORMATION IS FOR INTERNAL USE ONLY OR YOU MA...

Page 22: ...18 Customer Service ATTN Warranty Department 13259 East 166th Street Cerritos Ca 90703 Fax No 562 802 3391 Place Postage Here Cut Here ...

Reviews: