background image

99042958B

KEY

NO.

PART NO.

DESCRIPTION

1

99110752

Grille Only

2

99140137

Grille Springs (2 Required)

97009346

Grille Assembly (Includes Key

  Nos. 1 & 2)

3

99080254

Motor (T050)

4

98006791

Motor Plate

5

99110655

Blower Wheel

6

99260428

Nut #6-32 (2 Required)

7

97008632

Damper/Duct Connector

8

99270748

Receptacle

9

98006773

Wiring Cover

10

99390015

Ground Clip

11

97008319

Housing Assembly

 

Order replacement parts by part number - not key

number.

1

2

6

3

5

11

9

8

7

4

SERVICE PARTS

6. Install 3" round duct onto damper/duct connector. If rigid ductwork

is  used, its seam should be positioned at top of damper/duct

connector. Tape the joint and extend ducting to a wall cap or roof

cap. Make sure the damper operates freely. Ceiling or wall can now

be finished.

7. Replace the motor plate removed in Step 1. Insert two motor plate

tabs into slots in housing and then pivot  motor plate up until third

tab on plate snaps into matching slot in housing. Make sure tabs

hold motor plate securely in place. Plug in motor.

8. Squeeze grille springs together and insert springs into slots

in motor plate. Push grille up against ceiling or wall.

Limitation of Warranties and Claims

Seller warrants to the original purchaser that the goods sold hereunder shall be free from defects in workmanship and material under normal use and service (except in those cases where the materials

are supplied by the buyer) for a period of one year from the date of original installation or eighteen (18) months from the date of shipment, whichever occurs first. The liability of seller under this warranty

is limited to replacing, repairing, or issuing credit (at cost, F.O.B. factory and at seller’s discretion) for any part or parts which are returned by buyer during such period provided that:
a. seller is notified in writing within ten (10) days following discovery of such defects by buyer, or within ten (10) days after such defects should reasonably have been discovered, whichever is less;
b. the defective unit is returned to seller, transportation charges prepaid by buyer.
c. payment in full has been received by seller or said products; and
d. seller’s examination of such unit shall disclose to its satisfaction that such defects have not been caused by misuse, neglec t, improper installation, repair, alteration, act of God, or accident.
No warranty made hereunder shall extend to any seller product whose serial number is altered, ef

faced or removed. Seller makes no warranty, express or implied, with respect to motors, switches, controls,

or other components of seller’s product, where such components are warranted separately by their respective manufacturers. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES,

EXPRESS OR IMPLIED, WHETHER STATUTORY OR OTHERWISE, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. In no event shall

seller be liable to buyer for indirect, incidental collateral, or consequential damages of any kind. (BUYER’S F

AILURE TO PAY THE FULL AMOUNT DUE WITHIN SIXTY (60) DAYS OF DATE OF INVOICE

SHALL OPERATE TO RELEASE SELLER FROM  ANY AND ALL LIABILITY OR OBLIGATION ARISING PURSUANT TO ANY WARRANTY, EXPRESS OR IMPLIED,  WHETHER STATUTORY OR

OTHERWISE, INCLUDING ANY IMPLIED WARRANTY OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE IN CONNECTION WITH ANY CONTRACT FORMED HEREUN-

DER. BUYER AGREES THAT SUCH FAILURE TO PAY SHALL CONSTITUTE A VOLUNTARY WAIVER OF ANY AND ALL SUCH WARRANTIES ARISING PURSUANT TO SUCH CONTACT.)

TWIN CITY FAN & BLOWER, 

5959 Trenton Lane, Minneapolis, MN 55442

Summary of Contents for T050

Page 1: ...l ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 3 Please read specification label on product for further information and require ments WARNING INSTALLATION MODEL T050 HOUSING FLAP HOUSING LINE IN RECEPTACLE GROUND WIRECLIP DETAIL SWI...

Page 2: ...discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably have been discovered whichever is less b the defective unit is returned to seller transportation charges prepaid by buyer c payment in full has been re...

Page 3: ...ioning Engineers ASHRAE and the local code authorities 5 When cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities CEILING VENTILATOR READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner Homeowner Use and Care information on page 4 WARNING 6 Ducted fans must always be vented to the outdoors 7 If this unit is to be installed...

Page 4: ...ick ceiling material Bend two tabs on side of housing 900 outward Lift housing until tabs contact underside of joist Mark the keyhole slot on both mounting brackets 3 Set housing aside and drive nails partially into joist at the top of both keyhole marks 4 Hang housing from nails and pound nails tight To ensure a noise free mount pound another nail through the top hole of each mounting tab New Con...

Page 5: ...ible to unit Do not allow cable to touch sides or top of unit after installation is complete 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 Additional mounting holes are provided for installations...

Page 6: ... of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such de fects by buyer or within ten 10 days after such defects should reasonably have been discovered whicheve...

Page 7: ...en cutting or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Neve...

Page 8: ...ite sides of housing upside down so housing is flush with finished ceiling DUCTING Horizontal blower discharge ROOF CAP ROUND ELBOW ROUND DUCT WALL CAP IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight Remove shipping ring...

Page 9: ...ing nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If desire...

Page 10: ...eller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably have been discovered whichever is l...

Page 11: ...cable codes and stan dards including fire rated construction codes and standards 4 Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent backdrafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Societ...

Page 12: ...X 4 FRAMING wide side down MOUNTING BRACKETS Attached to opposite sides of housing upside down so housing is flush with finished ceiling DUCTING Horizontal blower discharge ROOF CAP 10 ROUND ELBOW 10 ROUND DUCT WALL CAP NOTE Make sure the shipping tape is removed from the damper flap and that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure ...

Page 13: ...r mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If...

Page 14: ...ver occurs first The liability of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer duringsuch period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defects should reasonably h...

Page 15: ...ing or drilling into wall or ceiling do not damage elec trical wiring and other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place...

Page 16: ... flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and air tight 8 X 12 TO 12 ROUND TRANSITION 8 X 12 TO 12 ROUND TRANSITION 12 ROUND DUCT FINISHED CEILING MATERIAL Ventilator factory shipped in horizontal discharge position MOUNTING BRACKETS factory shipped in position for ceiling material 8 X 12 TO 12 ROUND TRANSITIO...

Page 17: ...er assembly is completely dry before reinstalling Motor is permanently lubricated Do not oil or disassemble motor USE AND CARE Ventilator is designed for continuous operation If desired it may be controlled using an on off switch or a solid state variable speed control Follow wiring instructions packed with control and adhere to all local and state codes and the National Electrical Code 18 1 to 2 ...

Page 18: ...ate of shipment whichever occurs first The liability of seller under this warranty is limited to replacing repairing or issuing credit at cost F O B factory and at seller s discretion for any part or parts which are returned by buyer during such period provided that a seller is notified in writing within ten 10 days following discovery of such defects by buyer or within ten 10 days after such defe...

Reviews: