background image

Analizador de humedad Fuzhou

FZ-MA100C

Summary of Contents for FZ-MA100C

Page 1: ...Analizador de humedad Fuzhou FZ MA100C ...

Page 2: ...Moisture Analyzer Operation Manual ...

Page 3: ...mode setting 10 4 4 Heating mode setting 11 4 5 Timing mode setting 11 4 6 User defined 12 5 Calibration 12 6 Testing steps 13 7 Optimize analyzing 14 7 1 Heating temperature 14 7 2 Heating time 14 7 3 Sample weight 15 7 4 Sample preparation 15 7 5 Sample species 15 8 Time setting 16 9 Data communication 16 9 1 RS232 data setting 17 9 2 RS232 pin 17 10 Data Storage 18 11 Maintenance and troublesho...

Page 4: ...ods making testing work fast and simple Multiply productivity and accuracy of measurement results compared to mechanical products The average sample can be measured in just a few minutes The instrument is simple to operate accurate to test the display part of the value is clearly visible and can display the moisture content value dry matter content value sample initial value final value measuremen...

Page 5: ...aning the moisture analyzer 1 2 6 Make sure there is enough space around the moisture analyzer and at least 1 meter above it 1 2 7 The moisture analyzer must be operated only by trained personnel who are familiar with the performance of the tested sample and the operation of the equipment Please use the relevant safety things to operate the moisture analyzer such as safety glasses gloves protectiv...

Page 6: ...ll release toxic and corrosive gases during heating so it is recommended to use as few samples as possible Note The user is should take all responsibilities for any damage caused by testing the above types of samples Specification of moisture analyzer Max weighing 100g 100g 100g Display division 0 001g 0 005g 0 01g Readability sample 10g 0 01 0 05 0 1 Heating source Halogen lamp Temperature settin...

Page 7: ...lyzer should be placed on a stable level surface console Choose a safe and well ventilated location Samples with corrosive or toxic fumes and other hazardous materials need to be specially prepared for placement Please try to avoid placing the moisture analyzer in places with extreme temperature fluctuations excessive humidity airflow vibration electromagnetic fields heat sources or direct sunligh...

Page 8: ... at least 60 minutes of power up 2 5 Adjustment level The moisture analyzer has a horizontal bubble and two horizontal adjustment feet To compensate for the effect of the tilting symmetry of the placement position during the weighing process the horizontal foot can be adjusted until the horizontal bubble is at the center position Note The level must be re adjusted each time the position changes Op...

Page 9: ... minutes seconds heating method fast Opera ting mode Auto Auto standard Time Time slow 3 2 Control panel keypad Control panel function description 7 Button Functi on key operat ing Features Setting Hold Set heating parameters Press End of test switch water content solid content and other parameters Print Hold Date time setting Press Print function key after the test is completed Parameter indicato...

Page 10: ... analyzation User set the analyze time when time out the machine will stop the analyzing automatically 4 High Precision Medium Precision Low Precision 5 The moisture analyzer heating method Fast heating Heat to a set temperature in short time Standard heating Heat to a set temperature in normal time Slow heating Heat to a set temperature in long time 8 Tare Hold Tare function key in weighing state...

Page 11: ...oups of measuring method and parameters User can store 15 groups from 1 15 of different measuring method and parameters base on different samples for easy to use Group 16 is the warm up parameter User can set the machine warm up way base on working mode time and temperature Machine warm up can without weighing or samples Warm up machine before use can let machine has best working status can evapor...

Page 12: ...mand Step description Display Working mode selection 0 000 g Long press Set Press 3 seconds parameter number is blinking Short press Set Temperature number blinking xxxx Short press Set The working mode setting is bilinking High precision with automatically working mode Auto Hi Medium precision with automatically working mode Auto M Low precision with automatically working mode Auto Lo Timed worki...

Page 13: ...me setting Button command Step description Display Working mode selection 0 000 g Long press Set Press 3 seconds parameter number is blinking Short press Set Temperature number blinking xxxx Short press Set The working mode setting is blinking Short press Circle to timed mode and start to set time Time Short press Set The flashing position is second 10 00 Short press Set The flashing position is m...

Page 14: ... return to standby mode 5 Moisture analyzer calibration The moisture analyzer uses the relative weight to measure the result so a small deviation from the absolute weight has less influence on the accuracy of the measurement The moisture analyzer is stable in weighing performance and has a small temperature influence which can maintain the calibration result for a long time so weight calibration i...

Page 15: ...id press START key to start the measurement when machine display stable On the left of display flash means machine are under heating condition 6 3 After finishing the display will show the sample s moisture value Press Set can switch to check the other testing result Press TARE key can exit and return to standby mode and wait for a new testing Note 1 During measuring user can press STOP to call of...

Page 16: ...sed nor changed It is generally set to 105 except if the sample and user have special requirements Some samples have different moisture content at different heating temperatures In this case try to adjust the heating temperature to compensate for the measurement deviation 7 2 Heating time The moisture analyzer provide three simple way Auto mode recommend mode When machine detect a change in weighi...

Page 17: ...e table mention that the sample weight should be at least 2g The following test data is for informational purposes only 7 4 Sample preparation Samples need to be representative of the test in order to obtain accurate and repeatable measurements When preparing samples ensure that the samples are placed evenly on the sample tray to avoid build up and excessive quantities 7 5 Pasty fat containing sol...

Page 18: ...lity 8 Time Setting Button command Step description Display Standby status OFF Long press Set Press 3 seconds T SET Later display will show and flash year month day hour minute Short press Set move the flash position to set Short press to increase or decrease the setting value Long press to quickly increase or decrease the setting value Long press Set Press 3 seconds if all setting finish TE End S...

Page 19: ...er Machine Serial port printer 9male 9female 9male 25female 2 2 2 3 3 3 3 2 5 5 5 7 9 Data communication After the test completes a set of moisture values the moisture value remains until the Start Stop key is pressed During this period you can press the Print key to output the test value dry weight of the material print time etc To an external device RS232 Output format INITIAL WEIGHT 7 909g FINA...

Page 20: ... start to heat Lo Remind that the test sample weight is less than the minimum of required sample weight CAL 0 Remind that machine will calibrate on zero no need to put any weight mass on pan C 100 Remind user to put 100g weight mass on pan for calibration C EnD The calibration was successful C Err The calibration failed If the fault message cannot be resolved or does not describe the problem with ...

Page 21: ... let the moisture meter work without monitoring 12 Warranty The product has a one year warranty from the date of sale During the warranty period products with quality problems for replacement or free repair Except in one of the following cases 1 The warranty period has passed 2 Damage to the moisture meter due to the user s own fault 3 The user did not operate according to the instructions and cau...

Page 22: ......

Reviews: