05 MENU OPERATIONS
[7] SYSTEM
SYSTEM
F-10A
DEFAULT
LUMINANCE
INTERNAL PAT
DISPLAY ENABLE
ECO SAVING
SW UPGRADE
DHCP
IP ADDRESS
SUBNET MASK
GATEWAY
PORT
APPLY
MAC ADDRESS
VERSION
SERIAL NUM
OFF
OFF
OFF
OFF
OFF
STATIC
192.168.1.80
255.255.255.0
192.168.1.1
10262
OFF
FF:FF:FF
SW 00 FPGA 00 BOARD 00
12345678
100
• DEFAULT
- Used to initialize OSD values to factory default.
- Available modes are DEFALUT and FACTORY.
- In the DEFALUT mode, except for the stored 3D
LUT, all values are initialized.
- In the FACTORY mode, all values are initialized to
factory default.
• LUMINANCE
- Used to indicate the current Luminance value .
- In the case of System Default, the value returns
to factory default(after color calibration).
- Available values are from 0 to 50.
• INTERNAL PAT (INTERNAL PATTERN)
- Generates ColorBar, Pludge and Grayscale
Pattern internally.
- Selectable range for Gray Pattern is from 0% to
100% with 5% increment.
* See section “7. Other Function -> [12] Internal
Pattern” for more information.
• DISPLAY ENABLE
- Used to set the LUMINANCE to the minimum
value when the time set in the still image output
is exceeded.
- When video is output or the MENU button is
pressed, the LUMINANCE is reset to the original
value.
- Settable options are ON, 5MIN, 10MIN, 20MIN
and 30MIN.
- In the Function Key, the screen can be turned
ON/OFF immediately by user’s choice.
• ECO SAVING
- Used to save power consumption automatically
when there is no monitor signal.
- When the signal is supplied, the brightness of
the monitor will be changed to the set value.
• S/W UPGRADE
- Used to upgrade the firmware using USB (Thumb
drive).
* See section “7. Other Functions -> [13] Firmware
Upgrade” for more information.
• DHCP
- Used to activate/deactivate the DHCP function.
• IP ADDRESS / SUBNET MASK / GATEWAY
- Used to set the IP Address connected to a
Monitor.
• PORT
- Used to set the port number of the monitor.
- Default is set to 10262.
• APPLY
- Use to apply changed value of IP Address, Subnet
mask, Gateway and Port no.
• MAC ADDRESS
- Displays the MAC Address.
• VERSION
- Displays current firmware version.
• SERIAL NUM (Serial Number)
- Displays the serial number of the monitor.
PAGE (1/2)