Step1
1.
Select a right place for the new lift installation.
PIC.3
2.
This lift must be installed on a solid level concrete floor with no more than 0.15 degree of
slope. Or, the four points under the posts should be in level within 10mm.
3. The thickness of the concrete should be at least 4”. The intensity of the concrete should be
3,000 PSI.
4.
Draw a chalk line layout.
REV A-090413