Service Manual 73
Page 28 of 32
9. Hand-rotate the pump to ensure that it rotates freely without binding.
Standard End Clearances For GlobalGear Series Pumps
Pump Size
Cast Iron
Stainless Steel
GG015
0.003 - 0.005 inch ( 0.076 - 0.127mm)
0.006 - 0.008 inch ( 0.152 - 0.203mm)
GG030
0.003 - 0.005 inch ( 0.076 - 0.127mm)
0.006 - 0.008 inch ( 0.152 - 0.203mm)
GG050
0.005 - 0.007 inch ( 0.127 - 0.178mm)
0.008 - 0.010 inch ( 0.203 - 0.254mm)
GG070
0.005 - 0.007 inch ( 0.127 - 0.178mm)
0.008 - 0.010 inch ( 0.203 - 0.254mm)
GG080
0.005 - 0.007 inch ( 0.127 - 0.178mm)
0.008 - 0.010 inch ( 0.203 - 0.254mm)
GG090
0.005 - 0.007 inch ( 0.127 - 0.178mm)
0.008 - 0.010 inch ( 0.203 - 0.254mm)
GG120
0.007 - 0.009 inch ( 0.178 - 0.229mm)
0.013 - 0.015 inch ( 0.254 - 0.381mm)
GG130
0.007 - 0.009 inch ( 0.178 - 0.229mm)
0.013 - 0.015 inch ( 0.254 - 0.381mm)
GG200
0.008 - 0.010 inch ( 0.203 - 0.254mm)
0.013 - 0.015 inch ( 0.254 - 0.381mm)
GG210
0.008 - 0.010 inch ( 0.203 - 0.254mm)
0.013 - 0.015 inch ( 0.254 - 0.381mm)
Table 5 - End Clearance Values for standard clearances
Note: Many Tuthill pumps are provided with non-standard clearances for use with high viscosity
or high temperature fluids. Consult the factory for clearances of these pumps.
1. REFIT COUPLING AND GUARD:
If you have been able to take advantage of the modular design of this pump, the complete
overhaul has been accomplished without removal of the housing from the base plate or
piping. Thus, your original coupling alignment should be intact.
Refit the coupling and spacer, double-check alignment and complete any final adjustments.
Safety Relief Valve Instructions
Tuthill provides safety relief valves on pumps for over-pressure protection only. They are not
intended for use as flow control devices or any other similar use.
!
CAUTION
Continuous operation of the valve results in excessive heat build up within the pumping cavity,
which could cause serious internal damage.