OPERATION
1
2
REFERENCE PERFORMANCE CURVES
Beginning on page 10 prior to operating heater.
3
4
TURN ON AIR
Set pressure or flow to desired operating level.
SET DESIRED TEMPERATURE
1
2
TURN OFF MAIN POWER
3
CONTINUE AIR FLOW
Allow air to continue to flow for a minimum of 1 minute
or until exit air temperature is 300°F/150°C or less for
safety. Continue airflow longer as necessary to prevent
burn hazard to personnel.
TURN OFF AIR TO SYSTEM
5
CONTROL AIRFLOW
Ensure airflow is on before voltage is applied to heater. The heater should NOT be operated with an airflow of less that
1 SCFM or 60 SCFH may cause the heater’s element to overheat too quickly and burnout.
6
CLOSED OR OPEN-LOOP SYSTEM
If using a closed loop system, turn on power to the temperature and power controller, then set the desired temperature
on the temperature controller. If using an open loop system, increase power to the heater through the power controller
until the desired temperature is attained.
START-UP
SHUT-DOWN
X
X
ENERGIZE MAIN POWER LINE
Via disconnect switch or circuit breaker on control cabinet.