This alternate screen displays the following new information:
1. Dive Number—This indicates whether, on the date in ques-
tion, the log data displayed is for dive number 1, 2, 3, etc.
2. Actual Bottom Time—This includes any safety stop or
mandatory decompression stop time.
3. FO
2
Setting—This appears the same as it would while in
Dive Plan Mode.
4. Water Temperature—The water temperature measured at
the deepest point during the dive.
While the alternate Log Mode display appears, pressing button B
will scroll through the ten dives stored in memory, just as it does
when the primary display screen appears. Pressing button A again
will return the IQ-600 to its primary Log Mode display screen.
Warnings you may encounter: Log Mode also provides a
record of the warnings that may have appeared during the dive.
These will appear largely the same as they did during the dive,
and include:
Ascent Rate Warning
Decompression Stop Violation
PO
2
Warning
Oxygen Limit Index (OLI) Warning
Out-of-Range Warning
To exit this mode: You can exit Log Mode in a variety of
ways, including:
Go Diving—The IQ-600 will automatically enter Dive Mode.
Return to Surface Mode—You can do so by simply pressing
and holding button B for at least three seconds.
Do Nothing—If you take no further action, the IQ-600 will
return automatically to Surface Mode within five to six minutes.