Cleaning and maintenance
5816,0013US / Version 02
69
2.
Remove
contamination
from
the outside of the barrier housing
properly using water with washing-up liquid and a square of
cloth. Do not bring control units and electrical components in
contact with moisture.
3.
Remove dust inside the housing with a vacuum cleaner.
4.
After cleaning work, check that all previously opened covers
are closed again and that all safety equipment functions
correctly.
11.5 Maintenance schedule
The following describes the maintenance work that is necessary for
optimal, trouble-free operation. Maintenance intervals must be
observed.
If increased wear of individual components or functional groups is
revealed during regular inspections, the operator must reduce the
required maintenance intervals on the basis of the actual signs of
wear.
In case of queries regarding the maintenance work and intervals:
contact the manufacturer (for service address, refer to page 2).
Interval
Maintenance work
To be carried out by
Visual inspection of the housing, inside and out, for
damage and corrosion. Clean the housing and
repair paint damage as necessary. Remove
corrosion damage.
Specialist
Visual inspection of foundation anchors, mounting
profiles and mounting material for corrosion.
Remove corrosion damage.
Specialist
Visual inspection of the barrier arm for damage and
corrosion. Clean the barrier arm and repair paint
damage as necessary. Remove corrosion damage.
Specialist
Monthly
Visual inspection of additional parts for damage and
corrosion. Clean additional parts and repair paint
damage. Remove corrosion damage.
Specialist
Perform all monthly maintenance work.
Specialist
Check function of the Ground fault circuit interrupter
(GFCI).
Electrical specialist
Check the barrier housing fastening screws for tight
fit. If required, tighten the screws.
Specialist
Check the barrier arm and flange fastening screws
for tight fit. If required, tighten the screws.
Specialist
Every 6 months
Check the screws of the system parts for tight fit. If
required, tighten the screws.
Specialist