<NOTE>
The charger will send out an alert and
pop-up window if the battery packs
setting is incorrect (Image 38).
Input voltage is higher than 30V, check the power supply, then restart the charger
Input voltage is lower than the value of LOW INPUT VOLTAGE CUT-OFF, check
the power supply, then restart the charger.
Reverse polarity, check the connection between the charger and the battery,
correct the connection, then restart the work.
Battery disconnect, check the connection between the charger and the battery, then
restart the work.
Total voltage of the battery is over the termination voltage control (TVC), check the
battery and the TVC setting, then restart.
Total voltage of the battery is lower than the termination voltage control (TVC),
check the battery and the TVC setting, then restart.
Cell count detected by the charge is different from the setting, check the battery cell
count and reset the cell count of the work.
Cell voltage of the battery pack is over the termination voltage control (TAC), check
the battery and the TVC setting, then restart.
Cell voltage of the battery pack is lower the termination voltage control (TVC),
check the battery and the TVC setting, then restart.
Full battery, no need to charge.
External temperature is higher than the setting value, cutoff. Capacity is over than
the setting value, cutoff.
Capacity is over than the setting value, cutoff.
Time is up to the setting value of Saftey Timer, cutoff.