background image

15

Step 1.  Enter to Menu, Select Setting (Image 21), into set interface. (Image 22-24)

LiPo

LiFe

Lilo

LiHV

NiMH

NiCD

PB

Smart

SETTING

MONITOR

MEMORY

CALIBRATION

T240

CH1

CH1

CH2

CH2

1

SETTINGS

PUBLIC

SETTINGS

   CH1

SETTINGS

   CH2

Buzzer volume

Balance Speed

AC Power CH1/CH2

middle

normal

10.0V

Low input voltage

60W/60W

EXIT

SETTINGS

PUBLIC

SETTINGS

   CH1

SETTINGS

   CH2

INt.Temp Cut-off

Capacity Cut-off

Safety Time Cut-off

80 C

10A.0Ah

60 C

Ext.Temp Cut-off

240min

EXIT

SETTINGS

PUBLIC

SETTINGS

   CH1

SETTINGS

   CH2

INt.Temp Cut-off

Capacity Cut-off

Safety Time Cut-off

80 C

10A.0Ah

60 C

Ext.Temp Cut-off

240min

EXIT

PROGRAM OF SETTINGS

Set the volume of the buzzer. Keep Beep default: 

Middle, Low/

Middle/High/Off optional

In this menu, you can set the cutoff input voltage of the power supply 

of the charger to protect your power supply. The charger will cutoff 

working when input voltage lower than the setting value, Range from 

11.0-18.0V, Default: 10.0V

In this menu, you can set the cutoff internal temperature to protect 

your battery. The charger will cutoff working when the internal 

temperature is higher than the setting value range from 30°-85°C, 

Default: 80°C
In this menu, you can set the cutoff capacity to protect your battery. 

The charger will cutoff working when the capacity is more than the 

setting value. Range from off - 65.0Ah, Default: 10.0Ah

In this menu, you can set the cutoff external temperature to protect 

your battery. The charger will cutoff working when the external 

temperature is higher than the setting value (an External temperature 

sensor is needed). Range from 30-85°C, Default: 60°C
In this menu, you can set a safety time to protect your charger and 

battery. The charger will cutoff working when the safety time is up to 

the setting value. On/Off optional, range from 1-600 minutes,

Default: 240 minutes

Balance control of LiPo/Lilo/LiFe/LiHV, you can set the balance control 

to meet your demand. 

Normal

/Fast/

Slow

 optional. Default: 

Normal

* Fast: Balance speed fastest, less accurate. *

Slow

: Balance Speed 

lowest, more accurate.

*

Normal

: Balance speed and accurateness between Fast and 

Slow

In this menu, you can set the charge power limit to meet your power 

supply. The charge will work under the setting value.

Summary of Contents for T240 Reactor

Page 1: ...T240 T240 AC DC 10A Touch Charger...

Page 2: ...and MAX CHARGE CURRENT MAIN MENU INFO PROGRAM OF LiPo Lilo LiFe LiHV PROGRAM OF NiMH NiCd PROGRAM of PB lead Acid PROGRAM OF SMART PROGRAM OF SETTINGS PROGRAM OF MONITOR CALIBRATION PROGRAM OF MEMORY...

Page 3: ...SCREEN 3 2in AC 100 240V Power Switch PC Link PC Link DC 11 18V Thank you for purchasing the Reaktor T240 charger Designed for both rookies and professional this system is extremely versatile for the...

Page 4: ...h Charger 11 18V 0 1 10A 2 0 1 2A 2 1 6cells 2 1 15cells 2 2 20V 2 AC INPUT CH1 CH2 150W DC INPUT 120W 2 0 48kg 145x105x64mm Product Model Accessories AC Input Voltage DC Input Voltage Charge Power Ch...

Page 5: ...r close by a flammable object Use only in well ventilated areas Only charge the rechargeable batteries that meet the product specifications of this charger DO NOT allow water moisture or foreign objec...

Page 6: ...1 10 0A 7 4 0 1 10 0A 11 1 0 1 10 0A 14 8 0 1 10 0A 18 5 0 1 10 0A 22 2 0 1 10 0A 3 6 0 1 10 0A 7 2 0 1 10 0A 10 8 0 1 10 0A 14 4 0 1 10 0A 18 0 1 10 0A 21 6 0 1 10 0A 3 3 0 1 10 0A 6 6 0 1 10 0A 9 9...

Page 7: ...el 4 2V Cell Max Charge Voltage 3 7V Cell Discharge Voltage Cut off Level 3 0V Cell or Higher Voltage Level 4 1V Cell Max Charge Voltage 3 6V Cell Discharge Voltage Cut off level 3 0V Cell or Higher V...

Page 8: ...Six operation data Calibrate Charger Battery Management Checking Battery Capacity Voltage Balancer NOTE Please read carefully before doing anything Note 1 Two Channel are independent and you can use...

Page 9: ...CK icon into previous step Image 2 and touch START to balance charge Image 6 MODE 1 STORAGE MODE 2 CHARGE MODE 3 BAL CHARGE MODE 4 DISCHARGE Warning Next Step will be an example during operation T240...

Page 10: ...CH1 CH1 CH2 CH2 CH1 CH1 CH2 CH2 CH1 CH1 CH2 CH2 LiPo 6S BAL Charge 00 20 09 Ext Temp No Sensor Input Vol 14 73V Voltage 23 12V Current 0 60A Capacity 5mAh Int Temp 25 CC CH1 CH1 CH2 CH2 4 05V 80 80 80...

Page 11: ...to SET PARAMETER FOR NiMH BETTERY Image 9 Step 2 Select CHARGE MODE And set the related parameters Image 9 LiPo LiFe Lilo LiHV NiMH NiCD PB Smart SETTING MONITOR MEMORY CALIBRATION T240 CH1 CH1 CH2 CH...

Page 12: ...s are independent and you can use different modes to operate CH1 CH1 CH2 CH2 CH1 CH1 CH2 CH2 WORKING INTERFACE WORKING INTERFACE Step 4 Select previous data to START Image 11 to Discharge Image 12 or...

Page 13: ...interface Touch Unused icon to save the data and it will be easy for you to charge next time Image 15 16 TRICKLE Battery Cell Charge Current Discharge Current 6S 5A 2 40V S Delta v Invalid CHARGE DIS...

Page 14: ...FACE WORKING INTERFACE Step 4 Select previous data to START Image 16 to balance charging Image 17 or touch BACK icon into previous step Image 16 and touch START to balance charge Image 17 Note 1 Image...

Page 15: ...and Select Battery Type on the menu Image 1 Step 2 Select and adjust you desire battery related parameters image 2 Step 3 Select Start operation will begin image 3 Note Image 20 show the graphic photo...

Page 16: ...protect your battery The charger will cutoff working when the internal temperature is higher than the setting value range from 30 85 C Default 80 C In this menu you can set the cutoff capacity to pro...

Page 17: ...LiXx LiPo Lilo LiFe LiHV battery balancer Image 28 TWO Step 1 Enter to Menu select Calibration Image 29 into CHARGER CALIBRATION Image 30 Step 2 Select RESET Image 30 recover original setting Image 30...

Page 18: ...Current 6S 5 0A 4 20V S End voltage Invalid TRICKLE CHARGE DISCHARGE LiPo LiFe Lilo LiHV NiMH NiCD PB Smart SETTING MONITOR MEMORY CALIBRATION T240 CH1 CH1 CH2 CH2 1 Pb 6S Charge Curr 5 0A TVC 4 36V S...

Page 19: ...ery and the TVC setting then restart Total voltage of the battery is lower than the termination voltage control TVC check the battery and the TVC setting then restart Cell count detected by the charge...

Page 20: ...ypes of battery stated in this manual HobbyKing do not accept any liability if the charger is used for any purpose other than that stated We are unable to ensure you follow the instructions come with...

Page 21: ......

Reviews: