5. How to adjust outlet valve
Adjustment of FULL FLUSH volume:
Full adjustor down – full flush volume increases.
Full adjustor up – full flush volume decreases
1
2
3
4
5
FULL ADJUSTOR
Adjustment of HALF FLUSH volume:
Float cup down – half flush volume increases
Float cup up – half flush volume decreases
NOTE: Press the clip to adjust the half adjusting
float up and down
Half adjustor up - half flush volume decreases
Half adjustor down - half flush volume increases
NOTE: Please refer to instruction booklet provided with your product or the label on a lid
of the cistern for correct settings specific to your chosen wc suite.
FLOAT CUP
5˚
4
1
2
3
4
5
HALF ADJUSTOR
overflow tube
trim level
203mm
1
2
3
4
1
2
3
4
Flush adjustor
Float cup
Half adjustor
Overflow trim
½
0
2
203mm
CC
SETTINGS FOR YOUR TOILET