Setting
RFID channels – overview of the commands
188
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.5.20
Command: Query error/status of UHF read/write head
The
Read error/status of UHF read/write head
command enables error/status messages of the
UHF read/write head to be read.
Request
Loop counter
See description of the output data, [
Command code
0x0042 (hex.), 66 (dec.)
Read/write head address
Not required
Length of EPC
Not required
Start address
Address in the
Get Status response
record
Length
Length of the data to be read from the
Get Status response
record
0: Read entire
Get Status response
record
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data
Not required