Operating Instructions
Before operation
20
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
7.1.1
Mounting
Mounting the device in Zone 2 and Zone 22
In Zone 2 and Zone 22, the devices can be used in conjunction with the protective housing set
TB-SG-L (ID 100014865).
DANGER
Potentially explosive atmosphere
Risk of explosion through spark ignition
For use in Zone 2 and Zone 22:
Only install the device if there is no potentially explosive atmosphere present.
Observe requirements for Ex approval.
Unscrew the housing. Use Torx T8 screwdriver.
Replace the service window with the enclosed Ultem window.
Place the device on the base plate of the protective housing and fasten both together on
the mounting plate [
Connect the device [
22].
Mount and screw the housing cover according to the following figure. The tightening
torque for the screws is 0.5 Nm.
Fig. 13: Mounting the device in protection housing TB-SG-L