V2.0 | 2021/06
41
14
Technical Data
Technical data
RU40…-
M18…
RU130…-
M18…
RU40…-
M30…
RU130…-
M30…
RU300…-
M30…
RU600…-
M30…
Blind zone S
min
2.5 cm
15 cm
2.5 cm
15 cm
30 cm
60 cm
Operating range
40 cm
130 cm
40 cm
130 cm
300 cm
600 cm
Opening angle
9°
16°
9°
16°
15°
15°
Ultrasonic frequency
300 kHz
200 kHz
300 kHz
200 kHz
120 kHz
75 kHz
Standard target
20 × 20 mm 100 ×
100 mm
20 × 20 mm 100 ×
100 mm
100 ×
100 mm
100 ×
100 mm
Resolution
0.5 mm
1 mm
0.5 mm
1 mm
1 mm
1 mm
Minimum size – switching range 5 mm
10 mm
5 mm
10 mm
25 mm
50 mm
Repetition accuracy
0.15 % full scale
Temperature deviation
±1.5 % full scale
Operating voltage
15…30 VDC
Ripple
10 % U
SS
Rated operational current
≤ 150 mA
No-load current
≤ 50 mA
Voltage drop
≤ 2.5 V
Housing
Threaded barrel, CuZn, nickel-plated
Protection type to EN 60529
IP67
Conformity with standard
EN 60947-5-2
Connection type
Male connector, M12 × 1, 5-pin
Resistance to vibration and
mechanical shock
IEC 60068-2
MTBF value
195 years (SN 29500, Ed. 99…40 °C)
Operating temperature
-25…+70 °C
Storage temperature
-40…+80 °C
Weight
45 g (without
pushbuttons)/
51 g (with pushbuttons)
97 g (without pushbuttons)
/105 g (with pushbuttons)
308 g
(without
pushbut-
tons)/
326 g
(with push-
buttons)
Switching hysteresis
5 mm
10 mm
5 mm
10 mm
25 mm
≤ 50 mm
Switching frequency
7 Hz
8 Hz
7 Hz
8 Hz
4 Hz
1.6 Hz
Response time
75 ms
65 ms
75 ms
65 ms
125 ms
600 ms
Readiness delay
≤ 300 ms
Approvals
CE, UL